FL350 Series Universal Compact Inverter Input Ac220v Ac380v 0.4kw-7.5kw

Brand Name:MKFALE
Certification:CE
Model Number:FL350
Minimum Order Quantity:1
Delivery Time:5-30days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Ningbo Zhejiang China
Address: 浙江省宁波市奉化区萧王庙街道科程小微企业园1幢303
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Product

Model

Power

Adapter

Input

Voltage

Output Current

Installation

Distance

Overall

Dimensions

Packing

Dimensions

Net

Weight

Gross Weight
W*HL*W*TL*W*T
FL3500.4KW

220V-240V

50-60HZ


Single phase

220V-240V

50HZ-60HZ

2.1A91*145MM154*100*145MM173*135*172MM1.0KG1.2KG
FL3500.75KW4A91*145MM154*100*145MM173*135*172MM1.1KG1.3KG
FL3501.5KW7A91*145MM154*100*145MM173*135*172MM1.1KG1.3KG
FL3502.2KW9.5A91*145MM154*100x145MM173*135*172MM1.1KG1.3KG
FL3503KW11A91*145MM154*100x145MM173*135*172MM1.15KG1.35KG
FL3500.75KW

380V-440V

50-60HZ


Three phase 220V-240V 50HZ-60HZ

2.5A91*145MM154*100*145MM173*135*172MM1.1KG1.3KG
FL3501.5KW4.1A91*145MM154*100*145MM173*135*172MM1.1KG1.3KG
FL3502.2KW5.8A91*145MM154*100*145MM173*135*172MM1.15KG1.35KG
FL3503KW7.9A91*145MM154*100*145MM173*135*172MM1.2KG1.4KG
FL3504KW9.4A112*207MM218*215*174MM216*175*232MM2.3KG2.55KG
FL3505.5KW12.6A112*207MM218*215*174MM216*175*232MM2.35KG2.6KG
FL3507.5KW16.1A112*207MM218*215*174MM216*175*232MM2.35KG2.6KG

安装接线Installation Wiring



产品特点

Product Features

●Compact structure Features concise


●Excellent performance Stable quality


●Output voltage stabilization AVR function


●Wide voltage input


●Support keyboard exportation


●Double analog input


●Built-in EMC filter


●Built-in PID controller


●Built-in copper


端子功能说明

Terminal Function Description

Terminal Name

Terminal Use

Setting and Description

R

Inverter power supply:

The 380V model is connected to R,S and T

The 220V model is connected to R,S or R,T

Air switch shall be used as overcurrent protection device at the front end of inverter input power supply. If leakage protection switch is added, in order to prevent misoperation of leakage switch, please select equipment with sensitivity of more than 200mA and operation time of more than 100 ms.

S
T
U,V,W

Inverter output, connected to the motor

In order to reduce leakage current, the motor connection line should not exceed 50 meters

PE

grounding

The inverter should be well grounded
COM

Signal common terminal

Zero Potential of Digital and Analog Signals

S1

Digital input S1

Through parameter F9 setting,the factory defaults is forward

S2

Digital input S2

Through parameter F10 setting,the factory default is reverse

S3

Digital input S3

Through parameter F12 setting,the factory default is multi-speed first

S4

Digital input S4

Through parameter F13 setting,the factory default is multi-speed second

S5

Digital input S5

Through parameter F14 setting,the factory default is multi-speed third

GND

Signal common terminal

Zero potential of analog input signal

AVI

0-10V Signal Input

0-10V, input impedance: > 50kΩ

10V

Frequency setting potentiometer power supply

10V,最大10mA +10V, 10mA maximum
ACI

4-20mA Analog Input

4-20mA input impedance: 100 Ω

AO

Analog output signal

Set by parameters F24 and F25

RA

Relay output

Set with F14 parameter

Contact capacity: AC 250V/3A DC 24V/2A

RB
RC