Brand/Manufacturer | KOBERLEIN/USA |
Part Number | RMA-POWER-BOX 107/230 |
Alternate Part Number | RMA-POWER-BOX 107/230 |
Description | VIBRATION CONTROL MODULE |
Dimennsions | 14.0cm x 18.0cm x 7.2cm |
Weight | 0.5kg |
Product Details
RMA-POWER-BOX 107/230 Technical Data
Operating Voltage: 115 / 230V +/- 10% (must be set with the switch!)
Frequency: 50 .... 60Hz
Power consumption: max.60VA
Recommended Pre-fusing: 2 A / characteristic line C
Magnet – Output
adjustable output voltage: 15Vss ... 30Vss
adjustable output frequency: 10.00Hz ... 99.99 Hz
smallest frequency interval:0.01Hz
maximum connecting power: 50VA
Disconnection in case of: overcurrent, short circuit, derating, open circuit
Inputs
Input „vibration on“: current consumption at 24V DC: approx. 7mA
Input „Reset“: current consumption at 24V DC: approx. 7mA
Relay output floating:
Maximum contact load 30V DC 0.5A
Operating ambient temperature:
Storage: 0 ... 50°C; -25 ... 85°C
Measurements: W x H x D 140x180x72mm
EMV - Test According toEN55011; EN61000-3-3 (system perturbation)
Protection class: Ι (grounded)
Protection type: IP65 (with screwed connecting lines)
Moore News
Hydropower industry with power industry capabilities.
The working power of the remote I/O is provided by the
corresponding LCU to the unit local control unit (LCU1, LCU2, LCU3,
LCU4).
The LCU should provide an RS-485 serial interface, using the Modbus
(Master and Slave) standard communication protocol interface.
Molex is used for gateway protocol conversion. The module is
directly plugged into AB's 1756 rack and has standard blocks for
programming.
The international standard industrial Ethernet protocol EtherNet/IP
is used between the PLC and the workstation in the LCU.
The communication speed reaches 100Mbps, and the PLC adopts AB
ControlLogix system governor oil pump control loop and ball valve
control loop to enter the unit's local LCU control.
Thermal power industry with power industry capabilities: With the
development of society, network technology, computer technology and
PLC control technology are becoming more and more mature. All
auxiliary control systems of thermal power plants can enter the
whole plant auxiliary network control system to realize complete
monitoring operation in the centralized control room.The level of
automation has been greatly improved, and the efficiency of the
whole plant has been improved.
More Products
NI | PCIE-6321 | PHOENIX | IBS ST 24 BKM-T |
NI | SHC68-68-EPM | PHOENIX | QUINT-PS-100-240AC/24DC/10 |
NI | PXI-8186 | PHOENIX | QUINT-PS/1AC/24DC/20 |
NI | PXI-8106 | PHOENIX | 2832849 FL SWITCH SF 16TX |
NI | PXI-7813R | PHOENIX | UK5-HESI |
NI | SHC68-68-RDO | PROSOFT | MVI56E-MCM |
OMRON | CJ2H-CPU65-EIP | PROSOFT | MVI69-DFNT |
OMRON | 3G8F5-CLK01 | PROSOFT | MVI56E-MNETR |
OMRON | CQM1-TC101 | PROSOFT | MVI56E-MNETC |
OMRON | CPM1A-DRT21 | PROSOFT | MVI56-MNETC |
OMRON | CQM1-PA216 | PROSOFT | 3100-MCM |
OMRON | CP1H-XA40DT1-D | PROSOFT | AN-X2-AB-DHRIO |