Add to Cart
CNC Multifunctional Wire Hanger Making Machine is used to bland wire hanger making, nylon-coated wire hanger making, galvanized wire hanger making, stainless steel wire hanger making. It can produce different shape and size wire hanger, the wire hanger output is 30-45pcs /min according to size and shape requirement.
Steel Wire, Stainless Steel, Galvanized Wire Diameter: 1.5-3.8mm, Nylone-Coated Wire Diameter: 2.0-5.0mm.
Aluminium Wire: 2.0-5.5mm.
Change Mould can produce 11inch to 19inch wire hanger.
Servo motor Induction wire feeding, fault alarm, auto counting, electric wire pay off rack, and wire hanger collect rack. Touch screen is easy to operate. Stable performance. Romiter CNC wire hanger making machine is an ideal machine for wire hanger making.
a.CNC automatic hanger forming machine feed mechanism 750W-2000W
servo motor control, which is characterized by feeding speed, high
precision length.
b. fully automatic CNC hanger molding machine of the use of
three-phase 380V 1.5KW motor inverter control, easy to adjust the
molding speed
c. the automatic CNC hanger molding machine operation by
man-machine interface and touch panel operation buttons for
automatic operation and manual operation.
A.Interface through the man-machine interface "parameter adjustment
'automatic feeding speed setting', 'each feed length setting', 'Jog
feed speed setting'.
a.Automatic feeding speed setting role in the auto-run state, the
feeding speed. The unit is mm / S (seconds).
b.Each feed length setting role in the auto-run state, the total
length of each hanger; production monitoring interface 'Manual
feed' operation feed length. Units of 0.1mm.
c.Jog feed speed settings role in 'production monitoring'
interface, 'Manual feed' the feeding speed operation. The unit is
mm / S (seconds). The 'jog feed', 'jog back material' 'production
monitoring' interface speed for jog feed speed 1/2.
B."System Settings" interface by the man-machine interface 'feed
acceleration time setting', the '10mm corresponding pulse number
',' forming the number of errors set '
a.'Feed acceleration time setting', the '10mm corresponding pulse
number 'for system debugging, customers do not need to master.
b.'Molding the number of errors set' when the value exceeds the
molding tests are completed, the number of less than the number of
automatic feeding 'molding the number of errors set' value, the
system will alarm, the HMI display alarm information. When 'molding
the number of errors set' value is 0, the system will not be liable
molding error detection to shield this alarm.
A. machine interface operation
a. Jog feed: invalid operation in the loop runs; press this key,
servo motor feed mechanism feeding direction of continuous
operation, the release key feeding servo motor stops.
b. Jog back material: operating cycle operation is invalid; press
this key, the opposite direction of the feeding mechanism of servo
motor feeding continued operation, release the button, feeding
servo motor stops..
c. Manual feeding: operating cycle operation is invalid; press this
key once, the feeding mechanism of the servo motor operation once
the feed direction, the duration of a hanger feed length setting.
d. Stop the Beep: When the system fails, the man-machine interface
display failure information, buzzer, press this button, the buzzer
stops tweet. Upon failure to lift the man-machine interface display
fault information automatically cleared.
e. Automatically start: press this key hanger molding machine into
the cyclic operation, continuous production.
f. Automatic Stop: press this key, exit the loop hanger forming
machine run state, the system is in a wait state, need jog feed,
jog back material, manual feeding, manual jog or automatically
activated.
g. Accumulated cleared: press this button, the number of cumulative
production number cleared
h. Currently cleared: press this button, the current yield is
cleared.
B. Panel operation button
a. Power indicator: When the main power supply is powered on, the
control loop indicator lights.
b. Buzzer: When a system fault, the buzzer, the man-machine
interface displays the content of the fault, when the 'stop beep'
key press man-machine interface "production monitoring, regardless
of whether the failure to exclude, the buzzerwill stop the buzzer.
c. Speed adjustment: the molded motor inverter is used to adjust
the output frequency to control the speed of forming motor running.
d. The emergency stop button: abnormal or emergency situation
occurs when the hanger forming machine, press the emergency stop
button, the feed mechanism and forming institutions to stop action.
e.Manual Jog: When manually jog button is pressed, the molding
institutions motor to 10.00Hz frequency operation, slow the molding
agency action, easy to the product debug or mold test.
f. Cycle start and stop: When you press this button, the molding
machine into the circulation operation state; press this button
again to exit the loop forming machine running state.
a.When the molding machine is energized, and does not allow
mandatory rotation feeding servo motor, otherwise it will damage
the servo controller. For rotation feeding servo motor production
monitoring by the man-machine interface, "" 'jog feeding'' jog back
material'' manual feed' key.
b. Please ensure the molding machine and personal safety case to
operate the machine.
c. The power of the machine into the line for the three-phase
five-wire, three-phase line, a zero line, a ground wire. The line
voltage is 380V, phase voltage of 220V, the total power is about
3KW ensure reliable grounding.
a.Length Prefeeding standards
b. The speed can be adjusted according to diameter, any of the
speed.
c. The high speed is fast, the fastest production can produce 45
per minute.
d. Most convenient replacement mold (hangers styles) convenient and
simple, and the screen enter the required wire length, moving knife
position on the line
e. The aircraft can be adapted to the production of: 201 stainless
steel, 410 stainless iron, plating line, ordinary wire coated wire
and aluminum wire.
(PA11 tune about 2500, PA14 tune about 1500, PA38 400.)
Adjustment steps:
a.MOD key 2 times PA00 press the SET button to display the SEF-P.
b. By the middle of the two left shift on the shift key until PA11
press the SET button, press the middle two key adjusted to the
desired value and press the SET button.
Finished modifying parameters to save operation, during which the uninterruptible power. Press the MOD the key to wait until the the display EEPOP has been holding down the SET key display EE-O release, complete the save.
http://www.cnwirenail.com/wire-hanger-machine.html