Lab Analyzer Equipment 3-Parts Automatic Hematology Analyzer , Blood Test Machine


Model: MCL-880 and MCL-900


MCL-880 Automatic Hematology Analyzer


3-part differentiation of WBC, 23 parameters, single channel counter

● Volume measurement by time ,not wrong warning

● Adanced valve technology,long life

● RS232 interface, PC connecting

up to 35 samples test per hour

● Electrical resistance for counting and SFT method of Hemaglobin

● Low sample comsumption : venous 9.8 ul, capillary 9.6 ul, prediluted 20 ul for twice testing one time

● 8.4” color TFT, Windows interface all testing parameter displayed simultaneously

● Windows operation system graphical buttons mouse and keyboard operation

● Double convolution and intelligent fitting

● Automatic diluting , Mixing , rinsing and clog clearing

● Automatically sample probe cleanning (inside and outside)

● Large storage capacity: up to 10,000 samples +3 histograms

● Internal thermal-sensitive printer or external printer.

● RS232 interface, PC connecting


Main Technical Specifications

Methodology: Electrical resistance for counting, hemiglobincyanide method and SFT method for hemoglobin

Parameter: 3-part differentiation of WBC; 20 parameters and 3 color histograms (WBC, RBC, PLT)

Work mode : Single Channel + unique Hemoglobin test system

Sample volume: 9.6μL for Venous and capillary mode, 20μL for prediluted mode

Throughput: More than 35 samples per hour, operatable 24 hours a day, auto sleeping and waking-up functions

Storage: up to 100000 sample results including histograms can be stored, convenient for inquiry and management of history data

Operation langue: English

QC control : X-B, L-J, X , SD, CV %

Refrence Value Setting : Male , Female, Children, Neonate

Alarm : 25 test of alert messages

Input / output : RS232, parallel printer and keyboard

Print : Graphic thermal printer with various printing format, optional external printer

Temperature : 18℃ - 30℃,wet ≤ 10-90%

Power supply : 220 V ±22 VAC, 50±1Hz

Dimension : 33 CM ( L ) * 38 CM ( W ) * 43 CM ( H )

Weight : 20 KG


Precision

Parameters linear range CV %

WBC( 10 9 / L ) 0.0 - 99.9 ≤2%

RBC ( 1012 / L ) 0.0 - 9.99 ≤1.5%

MCV ( fL ) 40-150 ≤0.5%

PLT ( 10 9 / L ) 0-999 ≤4.0%

HGB( g/L ) 0.0-300.0 ≤1.5%


Parameters

WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB,HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV,PDW,PCT,L-PCR

3 –histograms : WBC,RBC and PLT


MCL-900 Automatic Hematology Analyzer

3-part differentiation of WBC, 23 parameters, Double channels counter

●Volume measurement by time ,not wrong warning

●Adanced valve technology,long life

● RS232 interface, PC connecting


up to 60 samples test per hour

● Electrical resistance for counting and SFT method of Hemaglobin

● Low sample comsumption : venous 9.8 ul, capillary 9.6 ul, prediluted 20 ul for twice testing one time

● 8.4” color TFT, Windows interface all testing parameter displayed simultaneously

● Windows operation system graphical buttons mouse and keyboard operation

● Double convolution and intelligent fitting

● Automatic diluting , Mixing , rinsing and clog clearing

● Automatically sample probe cleanning (inside and outside)

● Large storage capacity: up to 10,000 samples +3 histograms

● Internal thermal-sensitive printer or external printer.

● RS232 interface, PC connecting


Main Technical Specifications

Methodology: Electrical resistance for counting, hemiglobincyanide method and SFT method for hemoglobin

Parameter: 3-part differentiation of WBC; 20 parameters and 3 color histograms (WBC, RBC, PLT)

Work mode : Single Channel + unique Hemoglobin test system

Sample volume: 9.6μL for Venous and capillary mode, 20μL for prediluted mode

Throughput: More than 35 samples per hour, operatable 24 hours a day, auto sleeping and waking-up functions

Storage: up to 100000 sample results including histograms can be stored, convenient for inquiry and management of history data


Operation langue: English

QC control : X-B, L-J, X , SD, CV %

Refrence Value Setting : Male , Female, Children, Neonate

Input / output : RS232, parallel printer and keyboard

Print : Graphic thermal printer with various printing format, optional external printer

Temperature : 18℃ - 30℃,wet ≤ 10-90%

Power supply : 220 V ±22 VAC, 50±1Hz

Dimension : 33 CM ( L ) * 38 CM ( W ) * 43 CM ( H )

Weight : 20 KG


Precision

Parameters linear range CV %

WBC( 10 9 / L ) 0.0 - 99.9 ≤2%

RBC ( 1012 / L ) 0.0 - 9.99 ≤1.5%

MCV ( fL ) 40-150 ≤0.5%

PLT ( 10 9 / L ) 0-999 ≤4.0%

HGB( g/L ) 0.0-300.0 ≤1.5%


Parameters

WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB,HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV,PDW,PCT,L-PCR

3 –histograms : WBC,RBC and PLT