Technical Specifications:
DZD-6A survey & control unit
Measuring voltage range: -6000mV~+6000mV Measuring voltage
resolution: 0.01mV
Measuring voltage accuracy: (at Vp>10mV)±5%, ±1 digit; (at
Vp>10mV)±1%, ±1 digit
Measured apparent polarizability accuracy: ±1%, ±1 digit
Measuring current range: 0~5000mA Measuring current resolution:
0.01mA
Measuring current accuracy: (at Ip>10mA)±5%, ±1 digit; (at
Ip>10mA)±1%, ±1 digit
Input impedance: >50M ohm
Interference suppression on 50Hz power frequency: better than 80dB
Maximum power supply voltage: 900V Maximum power supply current: 5A
Power pulse width: 1-6 seconds, duty cycle 1:1
Working temperature: -10C Celcius ~ +50C Celcius, 95Rh
Weight: 8 kg
Volume: 305*200*202mm
DUK-2A multiplex electrode converter
Conversion electrodes: 60 channels or 120 channels
Operating mode: 16-key keypad with 90 character LCD display
combines to form man-machine dialogue operation.
Maximum allowable current: 2A
Maximum withstand voltage: 500V DC
Insulating property: 500M ohm
Working temperature: -10C Celcius ~ +50C Celcius
Weight: 7kg (60 channels)/ 7.5kg (120 channels)
Volume: 305*200*202mm (60 channels)/ 324*200*245mm (120 channels)
System composition
One DZD-6A multi-functional DC resistivity instrument as the survey
& control unit in the system, equipped with DUK-2A type 60
channels or 120 channels multiplex electrode converter, cables,
electrodes and other related accessories, together to form the
resistivity imaging system.
Main features
Multiple function in one machine: the instrument has four functions
including long lead IP instrument, 2D high density resistivity
meter 2D high density IP instrument and medium-power short lead
transmitter.
Easy for operation: the instrument adopts all-digital automatic
measurement, thus can execute automatic compensation for
spontaneous potential, drift and electrode polarization.
By adopting large screen LCD display in English characters, more
than fourteen types of wiring working modes can be directly
displayed in high-density measurement mode; in DZD-6A stand-along
mode, nine types of electrode arranging methods can be directly
displayed; meanwhile, real-time curve display can be realized
during working.