Corrosion Resistance Environmental Acetic Acid Salt Spray Chamber HL-90-CS for Testing Chromium Plating


Technical Data Download: iqualitrol Salt Spray Test Chamber HL-60-SS


Features:

1, Chamber material is made of P.V.C Sheet, sturdily and will not be out of shape.

2, Test chamber is heated from five directions to ensure the temperature is uniformity distributed.


3, Spray nozzle is specially made, enable to spray the salt water with considerable speed, then falls on the surface of samples.


4, Hot and moist air keeps the humidity in the test chamber conforms testing request.

5, High precision P.I.D. temperature controller limits the temperature difference within the range of ±0.1℃.


Technical Specifications:

Please Note Small Type of 60 and 90 do not meet standard of ASTM B117.

ModelHL-60-SSHL-90-BSHL-120-NSHL-160-NSHL-200-NS
Model (Touch Screen)HL-60-CSHL-90-CSHL-120-CSHL-160-CSHL-200-CS

Interior

dimensions

(mm)

W600900120016002000
D45060085010001200
H400500500550600

Exterior dimensions

(mm)

W11301460220026003000
D630910120014501650
H10701280145015501600
Chamber Volume108 L270 L480 L800 L1440 L
Solution Tank15L25 L40 L
Power SupplyAC 220V 50HZAC 380V 50HZ
Ambient temp. & humid. range+5℃ ~ +35℃ / <85%RH
Testing TemperatureNSS ACSS 35℃±1℃ / CASS 50℃±1℃
Air TemperatureNSS ACSS 47℃±1℃ /CASS 63℃±1℃
Solution ConsistenceNaCl 5%
PH ValueNASS ACSS:6.5~7.2 / CASS:3.0~3.2
Temperature fluctuation≦±0.5℃
Temperature uniformity≦2. 0℃
Temperature deviation≦±2.0℃
Spray quantum1.0~2.0(ml/80cm2/h)
Chamber Materialpolyvinyl chloride (PVC)
HeaterCorrosion-resistant titanium tube
Temperature sensorPlatinum Resistance (PT-100)
Safety deviceOver-temperature protection , leakage protection

Note:

1. The above specifications are for reference only, the actual specifications for the main quotation.

2. Custom made is available according to customers’ special requirements.


Brief Introduction:

Salt spray testing is popular because it is relatively inexpensive, quick, well standardized, and reasonably repeatable.


Although there may be a weak correlation between the duration in salt spray test and the expected life of a coating in certain coatings such as hot dip galvanized steel, this test has gained worldwide popularity due to low cost and quick results.


Most Salt Spray Chambers today are being used NOT to predict the corrosion resistance of a coating, but to maintain coating processes such as pre-treatment and painting, electroplating, galvanizing, and the like, on a comparative basis. For example, pre-treated + painted components must pass 96 hours Neutral Salt Spray, to be accepted for production.


Failure to meet this requirement implies instability in the chemical process of the pre-treatment, or the paint quality, which must be addressed immediately, so that the upcoming batches are of the desired quality. The longer the accelerated corrosion test, the longer the process remains out of control, and larger is the loss in the form of non-conforming batches.


The principle application of the salt spray test is therefore enabling quick comparisons to be made between actual and expected corrosion resistance. Most commonly, the time taken for oxides to appear on the samples under test is compared to expectations, to determine whether the test is passed or failed. For this reason the salt spray test is most often deployed in a quality audit role, where, for example, it can be used to check the effectiveness of a production process, such as the surface coating of a metallic part. The salt spray test has little application in predicting how materials or surface coatings will resist corrosion in the real-world, because it does not create, replicate or accelerate real-world corrosive conditions. Cyclic corrosion testing is better suited to this.


CASS TEST — COPPER-ACCELERATED ACETIC ACID SALT SPRAY (FOG) TEST — (ASTM B368, B117),

is a cyclic corrosion test that uses a solution of sodium chloride and ammonium sulfate which is much more dilute than traditional salt fog (spray).


Also known as the CASS test, this test is commonly used to evaluate paints on steel as well as to determine corrosion resistance of various aluminum alloys.


It is also used for testing chromium plating on zinc and steel die castings. It was developed specifically for testing decorative electrodeposited coatings of nickel/chromium and copper/nickel/chromium.


Uses include research and development, specification acceptance, manufacturing control of product or process, and simulated service evaluations.


China Corrosion Resistance Environmental Acetic Acid Salt Spray Chamber for Testing Plating supplier

Corrosion Resistance Environmental Acetic Acid Salt Spray Chamber for Testing Plating

Inquiry Cart 0