China Categories

40 Positions Single-Phase Meter Test Bench Output Max.240V &120A,0.05% accuracy class,Power supply 240V,50/60 Hz

Brand Name:SHENGDI TECHNOLOGY
Certification:GS,CNAS
Model Number:HS6103F
Minimum Order Quantity:1 SET
Delivery Time:35~45days
Payment Terms:TT,LC
Contact Now

Add to Cart

Active Member
Address: #8,Zhenghua Road,Wuyuan Industry Zone,Haiyan County
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

HS-6103F SINGLE PHASE ENERGY METER TEST BENCH

with 40 positions for electronic kWh meter, fission type by two fixing racks, automatic change to calibrate/test line and neutral

This specification for single phase dual loop energy meter test bench.


Voltage Source:

1. Output Voltage Range: 0- 275/300V

2. Output Max Power: 800VA

3. Resolution: 0.01%

4. Stability: Better than 0.05% / 3 Min(Time base 5S)

5. Distortion factor: < 0.5% at linear load;

6. Frequency range: 45Hz~65Hz;

7. Power efficiency: more than 85%;

8. Ambient temperature:10℃~50℃

9. Electronic overload and short-circuit protection.

Current Source:

1. Output current: range: 1mA~100A+/-20%;

2. Output maximum power: 2000VA

3. Resolution: 0.01%;

4. Stability: better than 0.05%/3 min(time base 5S);

5. Distortion factor: < 0.5% at linear load;

6. Frequency range: 45Hz~65Hz;

7. Power efficiency: greater than 85%;

8. Ambient temperature:10℃~50℃

9. Electronic overload protection and security for open current circuit.


Reference Meter:

HS-5100 Single Phase Reference Meter Accuracy class: 0.05%

Accessories:

1. Phase Angle: 0°~360°, resolution of phase angle setting: 0.1°;

2. Output frequency range: 45Hz~65Hz; resolution: 0.01Hz

3. Output stability of power: <0.05% (180S)

4. Input power: 230~240V±10%, 50/60Hz;

5. RS232 connectors for each position to be connected to Serial Ports Server,(for meter calibration & programming)

6. Current Connection Type: LNNL (1-4, 3-2) (Dual Loop)


Main Information:

No. of test MetersStandard: 24 and 48 ,Also 3-60 Meters are available
Accuracy Class0.05% or 0.1%
Output Voltage220 or 240V,Range:0~125%
Output CurrentStandard: Max120A Custom: 200A
Test Function

Accuracy testing,

creep testing(no load testing),

starting Up testing,

harmonic testing,

repeatability testing,

influencing testing,

dial testing etc.

Communication Mode

1.Bus
2.Seperated Communication Port(MOXA and Serial Port Server)


Dimensitions:

integrationstationsNumber of rackdimension:L×W×HfissionstationsNumber of rackdimension:L×W×H
611600×750×16001211600×700×1920
1600X800X11002412200×700×1920
1211600×750×19204822200×700×1920
2412200×750×19206022000×700×1920
4822200×750×1920cabinet600×800×1920

DELIVERY

China 40 Positions Single-Phase Meter Test Bench Output Max.240V &120A,0.05% accuracy class,Power supply 240V,50/60 Hz supplier

40 Positions Single-Phase Meter Test Bench Output Max.240V &120A,0.05% accuracy class,Power supply 240V,50/60 Hz

Inquiry Cart 0