Micro Load Cell 50N 100N 200N 500N Miniature Compression Force Sensor

Brand Name:Forsentek
Certification:CE
Model Number:FC10C
Minimum Order Quantity:1pc
Delivery Time:3~20 working days
Payment Terms:T/T,Western Union or Paypal
Contact Now

Add to Cart

Site Member
Location: Shenzhen Guangdong China
Address: 2# Jinlong Rd. Baolong Industrial Zone, Longgang Dist. Shenzhen China 518000
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Micro Load Cell 50N 100N 200N 500N Miniature Compression Force Sensor

Miniature Compression Load Cell Force Sensor FC10C is made of stainless steel based on metal foil stain gauge technology intended for compression force measurement. Micro Load Cell FC10C offers 50N / 100N / 200N / 500N four rated capacities to choose from.Small size compression load cell FC10C is featured with only 10mm outer diameter and 6mm total height which makes it extremely suitable for compression force measurement applications with limited mounting space.Typical applications for transducer FC10C are such as clamping force measuremen, force overload protection, load distribution analysis, pressing die force measurement, auto equipment, assembly line and so on. Miniature Force Transducer FC10C can also be modified or customized as per client's request.

Dimensions(in "mm")

Specifications

Capacity

5kg / 50N / 11lbf

10kg / 100N / 22 lbf

20kg / 200N / 44lbf

50kg / 500N / 110 lbf

Rated output1.0mV/V
Excitation3-10V
Zero balance±0.05mV/V
Nonlinearity±1% R.O.
Hysteresis±1% R.O.
Nonrepeatability±0.5% R.O.
Creep(3min)±0.5% R.O.
Safe overload150% F.S.
Ultimate overload200% F.S.
Compensated temperature-10...+40oC
Operating temperature-20...+60oC
Temperature shift zero±0.05% R.O./oC
Temperature shift span±0.05% R.O./oC
Input resistance900±100 ohms
Output resistance900±100 ohms
Insulation resistance>2000M ohms
Ingress protectionIP65
Material of elementStainless steel
CableØ2*4000mm 4-core shielded
Wiring code

Red--Excitation+ Black--Excitation-

Green--Signal+ White--Signal-


Load cell output: = (Power supply * Rated output) * Load / Capacity
Rated output is normally within 1mV/V~3mV/V.
Power supply is normally within 3-15V.
Load / Capacity is within 0-1.
So the load cell output signal is normally within 0-45mV(-45mV...+45mV for bidirectional load cell).
Example one: FC10C-20kg with 1.0mV/V sensitivity powered by 3.3V DC,the output range is 0~3.3mV.
Example two: FC10C-10kg with 1.0mV/V sensitivity powered by 5V DC,the output range is 0~5mV.

Load cell + Signal amplifier:
Load cell normally outputs -30mV...+30mV which sometimes can hardly be processed directly,so signal conditioner is introduced to convert mV signal into 0-5V/0-10V/4-20mA for easy signal processing.
Example: Micro Load Cell FC10C-10kg working with 0-10V amplifier,the load-output relationship will be 0-10kg load VS 0-10V output, when you get 1V output,it means the current load is 1kg,when you get 5V output,it means the current load is 5kg...

Micro Load Cell 50N 100N 200N 500N for Compression Force Measurement