Small Single Point Load Cell 1kg Single Point Loadcell Sensor 2kg

Brand Name:Forsentek
Certification:CE
Model Number:FH02
Minimum Order Quantity:5pcs
Delivery Time:3~25 working days
Payment Terms:T/T,Western Union or Paypal
Contact Now

Add to Cart

Site Member
Location: Shenzhen Guangdong China
Address: 2# Jinlong Rd. Baolong Industrial Zone, Longgang Dist. Shenzhen China 518000
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Small Single Point Load Cell 1kg Single Point Loadcell Sensor 2kg

Small size Single Point Load Cell Sensor FH02 is made of aluminum alloy based on strain gauge technology.Weight transducer FH02 offers 0.5kg / 1kg / 2kg / 3kg / 5kg / 6kg / 10kg / 15kg / 20kg nine rated capacities to choose from. Small Weight Sensor FH02 is temperature compensated to deliver stable readout throughout the working temperature range. Single point load cell transducer FH02 is corner trimmed for platform sizes up to 120x120mm, suitable for off-center load measurement.Beam loadcell FH02 is widely used for bench scales, weight monitoring laboratory equipment, home appliances, dosing machines and other weighing applications. Custom made service is available at Forsentek if the current specifications are not applicable.


Dimensions

Specifications

Rated capacity

0.5kg / 5N / 1.1 lb

1kg / 10N / 2.2lbf

2kg / 20N / 4.4 lb

3kg / 30N / 6.6 lbf

5kg / 50N / 11 lb

6kg / 60N / 13 lbf

10kg / 100N / 22 lb

15kg / 150N / 33 lbf

20kg / 200N / 44 lb

Rated output

0.5kg @ 1.0mV/V
1kg-20kg @ 2.0mV/V

Excitation3-15V
Zero balance±0.05mV/V
Nonlinearity±0.02% of the full capacity
Hysteresis±0.02% of the full capacity
Nonrepeatability±0.02% of the full capacity
Creep(5min)±0.02% of the full capacity
Safe overload150% of the full scale
Ultimate overload200% of the full scale
Compensated temperature0...+40oC
Operating temperature-20...+60oC
Temperature shift zero±0.03% R.O./10oC
Temperature shift span±0.03% R.O./10oC
Input resistance410±30 ohms
Output resistance350±10 ohms
Insulation resistance>5000M ohms
Ingress protectionIP65
Material of elementAluminum alloy
CableØ3*400mm 4-core
Wiring codeRed--Excitation+ Black--Excitation-
Green--Signal+ White--Signal-


A load sensor is a transducer that converts mechanical force into electrical signal which is proportional to the weight(or force) being applied.The measured load or force causes deformation of the measuring element(elastic body),the bonded strain gauge deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally, thus the load/force can be measured by measuring the output signal from the load cell which is normally within 0-30mV.Overloading is the most common cause of loadcell failure, a load cell is just like a spring in certain aspects, which will be damaged if overstretched. A machanical stop(refer to below picture) can be used to protect the sensor from excessive deformation. The gap distance can be determined by loading the sensor with rated capacity,then adjust the meachnical stop to reach the bottom of the transducer.In most cases,the load cell will be used to measure load at 30-60% of the full scale,thus the gap distance can also be adjusted using reference load a little higher than the target load to be measured instead of the rated capacity.

Small Single Point Load Cell 1kg Single Point Loadcell Sensor 2kg

Click here to download datasheet

China Small Single Point Load Cell 1kg Single Point Loadcell Sensor 2kg supplier

Small Single Point Load Cell 1kg Single Point Loadcell Sensor 2kg

Inquiry Cart 0