24V 48V 5kw Off Grid Inverter 2HP 15000VA Off Grid Power Inverter

Brand Name:MITSCN
Certification:ISO
Minimum Order Quantity:Negotiable
Delivery Time:5-8 working days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
voltage:24V 48V 24V 48V 48V 48VDC 48VDC 48VDC
Contact Now

Add to Cart

Active Member
Location: Beijing Beijing China
Address: Huixin PLaza, NO.8 Beichen East Road, Chaoyang District, Beijing,China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

MITPC3500 PRO Series (4KW-12KW)


• Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.) • Built-in MPPT solar charge controller 80A/100A/200A
• MPPT efficiency max 98%
• Powerful charge rate up to 140Amp

• DC start &Automatic Self-Diagnostic Function • WIFI / USB monitoring function (wi-fi optional) • Supporting AGS, BTS port
• Compatible to generator

MODELPC35 PRO- 4KPC35 PRO- 5KPC35 PRO- 6KPC35 PRO- 8KPC35 PRO- 10KPC35 PRO- 12K
Nominal Battery System Voltage24V48V24V48V48V48VDC48VDC48VDC
INVERTER OUTPUTRated power4KW5KW6KW8.0KW10.0KW12.0KW
Surge rating12000VA15000VA18000VA24000VA30000VA36000VA
Capable of starting electric motor2HP2HP3HP4HP5HP6HP
WaveformPure sine wave same as input (bypass mode)
Nominal output voltage RMS220V 230V 240VAC (±10%RMS)
Output frequency50Hz 60Hz ± 0.3Hz
Inverter effciency(peak)>85%>88%
Line mode efficiency>95%
Power factor1.0
Typical transfer time20ms(max)
AC INPUTVoltage230VAC
Selectable voltage range90-280 VAC (APL)
Frequency range50Hz 60Hz
BATTERYLow battery voltage cutoff20-24VDC for 24VDC mode (40-48VDC for 48VDC mode)
Low battery voltage recover21-25VDC for 24VDC mode (42-50VDC for 48VDC mode)
High battery voltage cutoff30VDC for 24VDC mode (60VDC for 48VDC mode)
High battery voltage recover28.5VDC for 24VDC mode (57VDC for 48VDC mode)
Idle consumption-search mode<30W when power saver on<80W when power saver on
AC CHARGEROutput voltageDepends on battery type
Charger AC input breaker rating40A40A50A80A80A80A
Overcharge protection S.D.31.4VDC for 24VDC mode (62.8VDC for 48VDC mode )
Maximum charge current80A60A100A70A80A100A120A140A
BTSContinuous output powerYes Variances in charging voltage & S.D. voltage base on the battery temperature
BYPASS
&
PROTECTION
Input voltage waveformSine wave (grid or generator)
Nominal input frequency50Hz or 60Hz
Overload protection (SMPS Load)Circuit breaker
Output short circuit protectionCircuit breaker
Bypass breaker rating40A63A63A63A
Max bypass current40Amp80Amp
SOLAR CHARGERMaximum PV charge current80A100A(200A optional)
DC voltage24V 48V Auto work48V
Maximim PV array power2000W4000W2000W4000W4000W5000W(10000W for 200A optional)
MPPT range @ operating voltage(VDC)32-145VDC for 24V mode,64-145V for 48V mode64~145VDC
Maximum PV array open circuit voltage145VDC
Maximum effciency>98%
Standby power consumption<2W
MECHANICAL SPECIFICATIONSMountingWall mount
Dimensions (W*H*D)620*385*215mm670*410*215mm
Net weight (solar CHG) (kg)36414169+2.575.75+2.575.75+2.5
Shipping dimensions (W*H*D)755*515*455mm884*618*443mm
Shipping weight (Solar CHG) (kg)56616482.5+2.589+2.592+2.5
OTHEROperation temperature range0°C to 40°C
Storage temperature-15°C to 60°C
Audible noise60dB MAX
DisplayLED+LCD
Loading (20GP/40GP/40HQ)140pcs 280pcs 320pcs

China 24V 48V 5kw Off Grid Inverter 2HP 15000VA Off Grid Power Inverter supplier

24V 48V 5kw Off Grid Inverter 2HP 15000VA Off Grid Power Inverter

Inquiry Cart 0