50Hz/60Hz 3 Phase Solar Pump Inverter , Practical Three Phase Motor Inverter

Brand Name:K-Drive
Certification:CE And ISO Certificated
Model Number:KD100
Minimum Order Quantity:1pcs
Delivery Time:1~7 Days
Payment Terms:L/C, D/A, D/P, Western Union, T/T, MoneyGram
Contact Now

Add to Cart

Active Member
Location: Shenzhen China
Address: Wisdom Lmgyu, baishixia community, Fuyong street, Bao 'an District, Shenzhen, China
Supplier`s last login times: within 34 hours
Product Details Company Profile
Product Details

KD100 Vector Variable Frequency Inverter AC Drive


Single phase three phase 0.75kw 1.5kw 1hp 2hp 220v solar pump inverter


K-EASY KD100 pump inverter Features:


1. Cover voltage levels 220V AC and 380V AC.

Support single-phase 220V and three-phase 220V/380V pumps,the power from 0.4KW to 37KW.


2. Easy to use

The inverters automatically start or sleep only after being connected to solar battery panels without any parameter setting.


3. Highly reliable for using multiple protective measures

Including PV over-voltage protection,PV polarity reverse warning,and auto derating against over-temperture,which extend product life.


4. Use advanced MPPT algorithms,ensuring that the solar power tracking efficiency reaches 99%


5. Models of 2.2kW or lower can be configured with boost module,meeting low-voltage work requirements.This reduces the use of solar battery panels and therefore the cost.


6. it can implement auto switch between solar input and grid input by configuring the boost or auto switching cabinet(meeting lightning protection requirements),implementing 24-hour unattended work.




Advantages

Thanks to sophisticated engineers, scientific producing workmanship, rigorous quality control systems and management team, K-Drive frequency inverters are equipped with advanced features, some of which are listed as below:

01. Starting torque: 180% at 0.5Hz (V/f pattern, SVC pattern);

02. Speed adjustable range: 1: 100 (V/f pattern, SVC pattern);

03. Speed accuracy: +/-0.5% (V/f pattern), +/-0.2% (SVC pattern);

04. Over load capability: 150% 1minute, 180% 10seconds;

05. Abundant frequency command sources;

06. Diverse input and output terminals;

07. Ambient temperature: -10°C~50°C;

08. High precise torque constraint, process PID control, multi-speed control, contracting brake control, field weakening control, all sides protection, etc;

09. Online and offline auto-tuning of motor parameters can both performed;

10. Extremely short-time acceleration can be performed without any trip, such as 0.1s or 0s from 0Hz to 50Hz;


Mains Supply (L1/L,L2,L3/N)
Supply voltage208-240V±10% 380-480V±10%
Power source frequency50/60Hz±5%
Displacement power factor (cos φ)(> 0.98)
Output Data (U, V, W)
Output voltage / frequency0-100% of supply voltage / 0.00-600.00 Hz or customized
Ramp time0.01-60000 S

Note:150% current can be provided for 1 minute, 180% for 10 seconds. Higher overload rating is achieved by oversizing the drive.


Digital Input
Programmable digital inputs5
LogicNPN or PNP
Voltage level22 - 26V
Analog Input
Analog inputs2
ModesVoltage or current
Level0 to +10V, 0/4 to 20 mA (scalable)
Automatic correctionYES
Relay Output
Programmable relay outputs1
RA - RB / TA - TBNormally close
RA - RC / TA - TCNormally open
Contact capacitance250VAC/3A, 30VDC/3A
Terminal 485 Interface
485+ / 485-Rate: 4800/9600/19200/38400/57600/115200 bps Max. distance: 500m
GNDIsolated from COM
Ambient
VibrationLess than 5.9 m/s² (0.6g)
HumidityRelative humidity 5% - 95 %. No condensation
Corrosive environment3C3
Ambient temperature-10 ºC - 50 ºC
Altitude0 - 2,000 m
Rated output current derated 1% every 100 m above 1,000 m
Storage temperature-40 - +70 ºC
EfficiencyEfficiency At rated amps: ≥93%
IP gradeIP20
Cooling methodForced air cooling
Fieldbus Communication
Modbus RTU, Modbus ASCIIBuilt-in





Applications

KD100 drives are economical series at K-Drive. They offer V/f control, including voltage and frequency separated control, adaptable to various industrial applications if sensor-less vector control is not required, including printing machines, packaging machines, pumps, fans and blowers, etc.



Production

In production, rigorous quality control is implemented on components, circuit boards, and the finished goods, assuring products without defects.


K-Drive VS Other brands

PerformanceCommon brandsK-Drive
Applicable motorsAsynchronous motorsAsynchronous /synchronous motors
Starting torque2.0Hz, 150% (sensor-less vector control) 0Hz, 180% (closed-loop vector control)0.5Hz, 180% (sensor-less vector control) 0Hz, 200% (closed-loop vector control)
Speed adjustable range1:100 (SVC), 1:1000 (VC)1:200 (SVC), 1:1000 (VC)
Ambient temperature (no derating required)-10-40ºC-10-50ºC (for most of the models)
Rated input voltage208VAC-400VAC208VAC-480VAC
CommunicationModbus RTU//ASCIIModbus RTU//ASCII Profibus-DP, CANopen, etc.
Position control (fixed length, or angular positioning)×
Field weakening control×
Autotune onlineOnlineOnline & Offline
Short-time ramp-upTripNo trip
Customized features (software and/or hardware)Unprocurable or no experienceProcurable with rich experienc