K-Drive braking unit use for any 400V 3 ph Inverter 220V 380V single phase Three Phase


Brand: K-Drive
Certificate: CE, RoHS

 
Product TypeRated Current(A)Crest CurrentMinimum ResistanceSize(mm)TerminalsDrawing Number
LL1WW1H
CDBR-201515A50A10Ω2402288555153M4Figure 1
CDBR-202225A75A6.8Ω2402288555153M4
CDBR-203030A85A2402288555153M4
CDBR-403015A50A20Ω2402288555153M4
CDBR-404525A75A13.6Ω2402288555153M4
CDBR-405530A85A12Ω2402288555153M4
CDBR-4075M35A100A10Ω2402288555153M4
CDBR-407535A100A320304187120163M6Figure 2
CDBR-411050A150A6.8Ω320304187120163M6
CDBR-416070A200A320304187120163M6
CDBR-422085A300A3.3Ω320304187120163M6
CDBR-4300120A400A2.5Ω320223193304160M6



Production

In production, rigorous quality control is implemented on components, circuit boards, and the finished goods, assuring products without defects.





How to maintenace inverter braker unit ?

Maintenance of an inverter breaker unit typically involves the following steps:

  1. Inspect the unit regularly for signs of wear and tear, such as cracks, corrosion, or loose connections. Ensure that all screws and bolts are tight, and that the unit is clean and free of debris.

  2. Check the air filters regularly and clean or replace them as needed. Dirty air filters can reduce the unit's efficiency and increase the risk of damage.

  3. Check the cooling system for leaks or blockages, and ensure that the coolant level is sufficient. Overheating can cause serious damage to the inverter breaker unit.

  4. Inspect the wiring and connections for signs of damage or corrosion. Tighten any loose connections and replace damaged wiring as needed.

  5. Test the unit's performance regularly, using appropriate testing equipment. This can help detect any potential issues before they cause serious damage or failure.

  6. Follow the manufacturer's recommended maintenance schedule and procedures. This may include tasks such as lubrication, cleaning, or component replacement.

  7. Consult with a qualified technician or electrician if you are unsure about any aspect of maintenance or repair. Inverter breaker units can be dangerous to work with, and proper training and expertise are essential for safe and effective maintenance.