8270A and 8370A Modular High-Pressure Controllers / Calibrators

Description of Fluke 8270A Multi Product Calibrator

Widest workload coverage in an automated high-pressure controller

The 8270A and 8370A are automated pneumatic high-pressure controllers that calibrate a wide workload of pressure sensors, covering twice the pressure ranges at twice the speed of other high-pressure controllers. Two models let you balance price and performance:
  • The 8270A measures and controls pressures from vacuum to 44 MPa (6400 psi). It can be configured with ranges as low as 100 kPa (15 psi).
  • The 8370A measures and controls pressures from atmosphere to 107 MPa (15 500 psi). It can be configured with ranges as low as 700 kPa (100 psi).
Fluke Calibration’s unique control technology enables you to use these calibrators at low or high pressures, all in the same instrument. Control precision is 0.002% of active range.
Expand workload coverage to both gas and liquid filled devices by using the optional Contamination Prevention System (CPS).
General specifications
Mains
Power requirements100 V ac to 240 V ac, 47 Hz to 63 Hz
FuseT 2 A, 250 V
Max power consumption100 W
Environment
Operating ambient temperature range15 °C to 35 °C
Storage temperature-20 °C to 70 °C
Relative humidityOperating: <80 % to 30 °C, <70 % to 40 °C
Storage: <95 %, non-condensing. A power stabilization period of four days may be required after extended storage at high temperature and humidity.
VibrationMIL-T-28800E
Altitude (operation)<3000 m
Warm up time15 minutes after power up or module installation, when items previously stored within Operating Ambient Temperature Range.
Compliance
Ingress protectionIEC 60529:IP20
SafetyIEC 61010-1, Installation Category II, Pollution degree 2
Weight and Dimensions
Weight (Chassis only)13 kg (28.5 lbs) / 15 kg (35.25 lbs)
DimensionsHeight: 147 mm (5.78 in)
Width: 452 mm (17.79 in)
Depth 488 mm (19.2 in)
Rack mount dimensions3U-19 inch rack
Electromagnetic Compatibility (EMC)
IEC 61326-1 (Controlled EM environmentIEC 61326-2-1; CIPR 11: Group 1, Class A
Group 1 equipment has intentionally generated and/or uses conductivity coupled radio-frequency energy which is necessary for the internal functioning of the equipment itself.

Class A equipment is equipment suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network which supplies buildings used for domestic purposes.

Emissions which exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of 61326-1 when test leads and/or test probes are connected.

USA (FCC)47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103.
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
Communication Interfaces
Primary Remote InterfacesIEEE, Ethernet, RS-232, USB
System ConnectionSupports interconnection of 2 or 3 systems
Switch Test ConnectionStandard BNC Jack:
Nominal 24 V dc isolated drive
Maximum 30 V dc w.r.t.chassis ground
Aux Drivers4 external Solenoid Drivers
24 V dc Drive (Maximum drive 6 W continuous per channel
Operating characteristics
Control specifications
95 % of setpoints are within specification limits for stated conditions as calculated by mean plus 1.67 standard deviations of test data.
Control Precision (Dynamic Mode)0.002% Range Span or 0.01 kPa (whichever is greater)
Control Turndown100:1 (typical)

To meet the control specifications, supply pressure should not be greater than 100 times the range of the measurement module. Control turndown is defined as the relationship between the provided supply pressure and the appropriate supply pressure for the range

Low Control Point1 kPa (0.15 psi) absolute (8270A only)
7 kPa (1.0 psi) gauge (8370A, 8270A without vacuum pump)
Settling TimeSettling time is the time required to be within 0.005% of setpoint for 10 % steps into volumes up to 50 cm3 for all pressures >7 kPa absolute (8270A) or 7 kPa gauge (8370A). Settling time may be affected by multiple variables, including temperature effects, component flow rates, leaks, and overall volume configurations.
Pressure Measurement Module (PMM)Dynamic A Mode 1Dynamic B Mode
Range < 44 MPaRange > 44 MPaRange < 44 MPaRange > 44 MPa
PM200/PM23030 seconds45 seconds60 seconds75 seconds
PM50035 seconds--60 seconds--
PM600/PM630;45 seconds60 seconds60 seconds75 seconds
1 8270A: Settling time for setpoints less than or equal to 200 kPa absolute may require an additional 15 seconds.
8370A: Settling time for setpoints less than or equal to 700kPa gauge may require an additional 15 seconds.
Overshoot (Dynamic A)0.08% Full Scale or 2 kPa (whichever is greater)
Overshoot (Dynamic B)0.008% Full Scale or 2 kPa (whichever is greater)
Pressure Limits
Supply Port (8270A/8370A)Maximum 48 MPa (7 000 psi) gauge / 110 MPa (16 000 psi) gauge
Minimum 2 MPa (300 psi) gauge for 8270A and 8370A
Test Port (8270A/8370A)44 MPa (6 400 psi) gauge / 107 MPa (15 500 psi) gauge
Reference Port150 kPa (22 psi) absolute
Vent Port150 kPa (22 psi) absolute
Relief Valves/Rupture Disk
8270A Chassis Supply port relief valve is set to 52 MPa (7 500 psi)

8370A Chassis Supply has a rupture disk installed which is designed to burst at
152 MPa (22 000 psi). Low pressure manifold relief valve is set to
52 MPa (7 500 psi).

Modules with full scales ≤ 44 MPa include pressure relief valves

Supply Gas Type
Clean Dry Nitrogen, Helium, Argon, or Air - Industrial Grade Nitrogen, 99.5%+
Vacuum Supply
>50 liters per minute capacity with Auto Vent feature

System will exhaust gas through the vacuum system when controlling down in pressure. Appropriate protections are necessary.

List of Options
8270A-2-BSPModular Pressure Controller Chassis, 2 Bay, BSP Manifold
8270A-2-BSP-PCMModular Pressure Controller, 2-Bay, BSP, W/PCM
8270A-5-BSP-PCMModular Pressure Controller, 5-Bay, BSP, W/PCM
8270A-2-NPTModular Pressure Controller Chassis, 2 Bay, NPT Manifold
8270A-2-NPT-PCMModular Pressure Controller, 2-Bay, NPT, W/PCM
8270A-5-NPT-PCMModular Pressure Controller, 5-Bay, NPT, W/PCM
8270A-2-SAEModular Pressure Controller Chassis, 2 Bay, 7/16-20 Manifold
8270A-2-SAE-PCMModular Pressure Controller, 2-Bay, SAE, W/PCM
8270A-5-SAE-PCMModular Pressure Controller, 5-Bay, SAE, W/PCM
8270A-5-BSPModular Pressure Controller Chassis, 5 Bay, BSP Manifold
8270A-5-NPTModular Pressure Controller Chassis, 5 Bay, NPT Manifold
PCM-STD-100MHigh-Pressure Control Module, Standard Turndown, 100 MPa (15 000 psi)
PCM-STD-40MPressure Control Module, 827X, Standard Turndown, 40 MPa (6000 psi)

FAQ:

1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .


China FCC Durable Multi Product Calibrator , Fluke 8270A Oscilloscope Calibrator supplier

FCC Durable Multi Product Calibrator , Fluke 8270A Oscilloscope Calibrator

Inquiry Cart 0