Practical 5080A Multi Function Calibrator 600 MHz High Performance

Brand Name:Fluke
Certification:FCC
Model Number:5080A
Minimum Order Quantity:1 set
Payment Terms:T/T
Place of Origin:USA
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: RA1-B2,F32 of Dongjianghaoyuan, Baomin Rd, Bao'an District, Shenzhen,China
Supplier`s last login times: within 28 hours
Product Details Company Profile
Product Details

Fluke 5080A High Performance Multi-product Calibrator

Description of Fluke 5080A Multi Product Calibrator

Calibration solutions for your analog and digital workload

  • High compliance
  • Protection circuitry
  • Calibrates a wide workload, including analog meters and 3.5 and 4.5 digits DMMs

The 5080A Multi-Product Calibrator calibrates your analog and digital workload accurately and economically. Its high voltage and current compliance makes analog workload calibration easy and precise. And built-in protection circuitry protects it against damaging input voltages.

This easy-to-use multifunction calibrator can handle a wide meter calibration workload that includes:

  • Analog meters
  • Panel meters
  • Digital multimeters
  • Watt meters
  • Clamp meters (with coil accessory)
  • Megohm meters (optional)
  • Oscilloscopes to 200 MHz (optional)
  • …and more

Versatile software applications enable you to record paperless results, and more. Best of all, the 5080A Multi-Product Calibrator offers this versatile functionality at a price that fits nicely into your budget.

Technical Specifications
Voltage DC
Range: 0 to ±1020V
Best 1 Year Specification: ±0.01% of setting
Current DC
Range: 0 to ±20.5A
Best 1 Year Specification: ±0.05% of setting
Resistance
Range: 0 to 190 MO, 19 values in x1 and x1.9
Best 1 Year Specification: ±0.025% of setting
Voltage AC
Range: 1 mV to 1020V
45Hz to 1 kHz, Sine
Best 1 Year Specification: ±0.1% of setting
Current AC
Range:29 mA to 20.5A
45 Hz to 1 kHz, Sine
Best 1 Year Specification: ±0.1% of setting
DC Power
Range:10.9 mW to 20.5 kW
Best 1 Year Specification: ±0.11% of setting
AC Power
Range: 10.9 mW to 20.5 kW
45-65 Hz, PF=1
Best 1 Year Specification: ±0.36% of setting
Phase
Range: 0 to ± 179.99°
45 Hz to 1 kHz
Best 1 Year Specification: ±0.25° of setting
Frequency
Range: 45 Hz to 1 kHz
Best 1 Year Specification: ±50 ppm of setting
General Specifications
Warm up Time
Twice the time since last warmed up, to a maximum of 30 minutes
Settling Time
Less than 5 seconds for all functions and ranges except as noted
Standard Interfaces
RS-232 and Ethernet
Temperature Performance
Operating: 0°C to 50°C
Calibration (tcal):15°C to 35°C
Storage:-20°C to +70°C
Temperature Coefficient
Temperature coefficient for temperatures outside tcal ±5 °C is 10 % of the stated specification per °C for temperatures in the range of 0 °C to 35 °C. Above 35 °C, the temperature coefficient is 20 % of the stated specification per °C.
Relative Humidity
Operating: <80% to 30°C, <70% to 40°C, <40% to 50°C
Storage:<95%, non-condensing
Altitude
Operating: 2,000m (6,500 ft) maximum
Non-operating: 12,200m (40,000 ft) maximum
Safety
Meets EN. 61010-1:2001, CAN/CSA-C22.2 No. 61010-1-04, UL 61010-1: 2004
Analog Low Isolation
20V
EMC
Meets EN613261:2006.
Line Power
Line Voltage (selectable): 100V, 120V, 220V, 240V
Line Frequency: 47 to 63 Hz
Line Voltage Variation: + 10% about line voltage setting
Power Consumption
600 VA
Calibration DocumentationReport of calibration with data included; 17025 accredited report optional
Dimensions
Height:19.3 cm (7.6 in)
Width:43.2 cm (17 in), 44.3 cm (17.5 in) including handles
Depth:53.8 cm (21.2 in)
Weight (without options)
22 kg (48 lbs.)
Absolute Uncertainty Definition
The specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. It is not necessary to add anything to determine the total specification for the temperature range indicated.
Specification Confidence Interval
99%

List of Options
Model NameDescription
5080AMulti-Product Calibrator
5080A/MEGMulti-Product calibrator with Megohm Meter Calibration Option
5080A/SCMulti-Product Calibrator with Oscilloscope Calibration Option
5080A/SC/MEGMulti-Product Calibrator with Megohm Meter and Oscilloscope Calibration Option


FAQ:

1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .

China Practical 5080A Multi Function Calibrator 600 MHz High Performance supplier

Practical 5080A Multi Function Calibrator 600 MHz High Performance

Inquiry Cart 0