5800A Fluke Oscilloscope Multi Function Calibrator Automatic Meter Error Calculation

Brand Name:Fluke
Certification:FCC
Model Number:5800A
Minimum Order Quantity:1 set
Payment Terms:T/T
Place of Origin:USA
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: RA1-B2,F32 of Dongjianghaoyuan, Baomin Rd, Bao'an District, Shenzhen,China
Supplier`s last login times: within 28 hours
Product Details Company Profile
Product Details

Fluke 5800A Multi-Product Calibrator

Description of Fluke 5800A Multi Product Calibrator
  • Automatic meter error calculation
  • X and D keys that change the output value to pre-determined cardinal values for various functions
  • Programmable entry limits that prevent invalid amounts from being entered
  • Edge, Leveled Sine, Pulse, Marker, and Wave Generation modes
  • Accurate oscilloscopic input impedance measurement
  • Tunnel Diode Pulse compatibility
  • External reference
  • Auxiliary input
  • 5-channel output (5-channel option). The 5-channel option allows you to calibrate up to five oscilloscope channels simultaneously without changing cables
  • Simultaneous output of a signal and a trigger signal
  • 600 MHz, Leveled Sine wave output
  • Standard IEEE-488 (GPIB) interface, complying with ANSI/IEEE Standards 488.1-1987 and 488.2-1987
  • EIA Standard RS-232-C serial data interface for printing, displaying, or transferring internally stored calibration constants, and for remote control of the 5800A
  • Pass-through RS-232-C serial data interface for communicating with the Unit Under Test (UUT)
  • Extensive automatic internal self testing and diagnostics of analog and digital functions
  • EMC Complies with EN 61326-1
  • Line Power Line Voltage (selectable): 100 V, 120 V, 220 V, 240 V
  • Line Frequency: 47 to 63 Hz
  • Power Consumption 250 VA

The Fluke Model 5800A Oscilloscope Calibrator is a precise instrument that calibrates analog and digital oscilloscopes.

The 5800A Calibrator may be operated at the front panel in the local mode, or remotely using RS-232 or IEEE-488 ports. For remote operations, several software options are available to integrate 5800A operation into a wide variety of calibration requirements.

Fluke 5800A Performance Characteristics

  • Form Factor: Benchtop
  • DC Volts Minimum Range: 6 V
  • DC Volts Maximum Range: 130 V
  • DC Volts No. of Ranges: 2 QTY
  • DC Volts Basic 1 yr accuracy: 0.05 %
  • AC Volts Minimum Range: 6.6 V
  • AC Volts Maximum Range: 130 V
  • AC Volts No. of Ranges: 2 QTY
  • AC Volts Minimum Frequency: 50 kHz
  • AC Volts Maximum Frequency: 600 MHz
  • DC Current Minimum Range: 100 uA
  • DC Current Maximum Range: 100 mA
  • DC Current No. of Ranges: 1 QTY
  • DC Current Basic 1 yr accuracy: 0.05 %
  • AC Current Minimum Range: 100 uA
  • AC Current Maximum Range: 100 mA
  • AC Current Basic 1 Year Accuracy: 0.25 %
  • Resistance Minimum Range: 40 Ohm
  • Resistance Maximum Range: 1.5 MOhm
  • Resistance Basic 1 yr accuracy: 0.1 %
  • Minimum Frequency: 50 Hz
  • Maximum Frequency: 600 MHz
5800A Mainframe Specifications
Voltage DC
Range:0 to ±6.6V (50Ω)
Range:±0.25%
------------
Range:0 to ±130V (1 MΩ)
Best 1 Year Specification:±0.025%
Voltage AC (Squarewave
Range:: 0 to ±6.6V (50Ω)
Best 1 Year Specification:±0.25%
--------
Range±1 mV to ±130V p-p (1 MΩ)
Best 1 Year Specification:±0.05%
Fast Edge
Range:4 mV to 2.5V p-p (50Ω)
Best 1 Year Specification:300 ps Rise Time
Leveled Sinewave
Range:50 kHz to 600 MHz
Best 1 Year Specification:50 kHz to 600 MHz
±1.5% Flatness
Time Markers
Range:5s to 500 ps
Spike, square, 20% pulse, sine
Best 1 Year Specification:±1 ppm
Wave Generator
Range:Range: 1.8 mV to 55V p-p (1 MΩ)
1.8 mV to 2.5V p-p (50Ω)
0.01 Hz to 100 kHz
Square, Sine, Triangle
Best 1 Year Specification:±3
Pulse Generator
Range:15 mV to 1.5V amplitude
Best 1 Year Specification:1 ns to 500 ns width ±5%
Best 1 Year Specification:1 ns to 500 ns width ±5%
DC Voltage Measurement
Range:0 to ±6.6V
Best 1 Year Specification:: ±0.05%
Current DC
Range:±100 mA to ±100 mA
Best 1 Year Specification:± 0.25%
Current AC
Range:100 mA p-p to 100 mA p-p
10 Hz to 100 kHz
Squarewave
Best 1 Year Specification:±0.25%
TV Trigger
NTSC, SECAM, PAL, PAL-M
Input Impedance Measurement
Range:40Ω to 1.5 MΩ
Best 1 Year Specification:±0.1%
--------
Range:5 pF to 50 pF
Best 1 Year Specification:±5%
Overload Measurement
5V to 9V (dc or ac squarewave), 5 to 60 seconds

List of Options
055 CHANNEL OUTPUT



FAQ:

1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .


China 5800A Fluke Oscilloscope Multi Function Calibrator Automatic Meter Error Calculation supplier

5800A Fluke Oscilloscope Multi Function Calibrator Automatic Meter Error Calculation

Inquiry Cart 0