Keysight N5227B PNA Microwave Network Analyzer 10 MHz To 67 GHz

Brand Name:Keysight
Certification:ISO17025
Model Number:N5227B
Minimum Order Quantity:1 set
Delivery Time:1~3 Working Days
Payment Terms:T/T,Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: RA1-B2,F32 of Dongjianghaoyuan, Baomin Rd, Bao'an District, Shenzhen,China
Supplier`s last login times: within 28 hours
Product Details Company Profile
Product Details

Highlights of Keysight N5227B PNA Microwave Network Analyzer

A Powerful Combination of Hardware and Software

The N5227B PNA network analyzer combines hardware and test software applications to deliver fast and accurate measurements for a variety of devices. Utilize network analysis software applications to explore, define, and resolve issues in your devices under test. Parameterize your amplifier, mixer, and frequency converter behavior with advanced test software applications including noise figure, EVM, and pulsed-RF.


Solve your most complicated measurement challenges with the N5227B VNA:


  • choose 2-port single-source or 4-port dual-source versions
  • leverage built-in pulse modulators and pulse generators for pulsed S-parameter measurements
  • get low receiver noise floor and high receiver compression level
  • achieve fast measurement speed: 3.6 to 23 μsec/point
  • measure S-parameters with the smallest uncertainty and highest stability

Definitions of Keysight N5227B PNA Microwave Network Analyzer

All specifications and characteristics apply over a 25 °C ±5 °C range (unless otherwise stated) and 90 minutes after the instrument has been turned on.


Specification (spec.): Warranted performance. Specifications include guardbands to account for the expected statistical performance distribution, measurement uncertainties, and changes in performance due to environmental conditions.


Characteristic (char.): A performance parameter that the product is expected to meet before it leaves the factory, but that is not verified in the field and is not covered by the product warranty. A characteristic includes the same guardbands as a specification.

Typical (typ.): Expected performance of an average unit which does not include guardbands. It is not covered by the product warranty.


Nominal (nom.): A general, descriptive term that does not imply a level of performance. It is not covered by the product warranty.


Supplemental performance data (SPD): A performance parameter that is tested on a minimal set of products during design validation. It does not include guardbands, and is not covered by the product warranty. Calibration: The process of measuring known standards to characterize a network analyzer's systematic (repeatable) errors.


Corrected (residual): Indicates performance after error correction (calibration). It is determined by the quality of calibration standards and how well "known" they are, plus system repeatability, stability, and noise.


Uncorrected (raw): Indicates instrument performance without error correction. The uncorrected performance affects the stability of a calibration. Standard: When referring to the analyzer, this includes no options unless noted otherwise. Find us at www.keysight.com


Page 9 Standard and LFE measurements: With an LFE option, which adds low frequency extension (LFE) hardware, the LFE measurement range overlaps with the standard measurement range from 10 MHz to 100 MHz. With LFE Enabled, measurements from 500 Hz to 100 MHz use LFE hardware. With LFE Disabled, measurements from 10 MHz to 100 MHz use standard hardware. To measure below 10 MHz, LFE must be enabled. All measurements above 100 MHz use standard hardware, regardless of the LFE Enabled/Disabled setting.


Options of Keysight N5227B PNA Microwave Network Analyzer

Hardware options
N5227B-2002-port, base hardware configuration
N5227B-2012-port with configurable test set, reference mixer switch
N5227B-2052-port with configurable test set, ref mixer switch, bias tees, low frequency extension
N5227B-2102-port with metrology configuration
N5227B-2192-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees
N5227B-2202-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees, low frequency extension
N5227B-4054-port with second source, configurable test set, reference mixer switch, bias tees, low frequency extension
N5227B-4204-port with second source, configurable test set, reference mixer switch, source and receiver attenuators, bias tees, low frequency extension
N5227B-4004-port with second source
N5227B-4014-port with second source, configurable test set, reference mixer switch
N5227B-4104-port with second source, metrology configuration
N5227B-4194-port with second source, configurable test set, reference mixer switch, source and receiver attenuators, bias tees
Calibration documentation
N5227B-1A7Calibration + Uncertainties + Guardbanding (Not Accredited)
N5227B-A6JANSI Z540-1-1994 Calibration
N5227B-UK6Commercial calibration certificate with test data
Additional hardware capability
N5227B-021Add pulse modulator to internal 1st source
N5227B-022Add pulse modulator to internal 2nd source
N5227B-020Add IF inputs
N5227B-UNYEnhanced low phase noise performance
Software with Subscription
S93007BAutomatic fixture removal
S93010BTime-domain analysis
S93011BEnhanced time domain analysis with TDR
S93015BReal-time S-parameter and power measurement uncertaint
S93025BBasic pulsed-RF measurement
S93026BAdvanced pulsed-RF measurements
S93029BNoise figure measurements with vector correction
S93080BFrequency-offset measurements
S93082BScalar mixer/converter measurements
S93083BVector and scalar mixer/converter measurements
S93084BEmbedded-LO capability
S93086BGain-compression measurements
S93087BIntermodulation distortion measurements
S93088BSource phase control
S93089BDifferential and I/Q device measurement
S930900BSpectrum analysis up to 8.5 GHz
S930901BSpectrum analysis up to 13.5 GHz
S930902BSpectrum analysis up to 26.5 GHz
S930904BSpectrum analysis up to 43.5 GHz
S930905BSpectrum analysis up to 50 GHz
S930907BSpectrum analysis up to 70 GHz
S930909BSpectrum analysis up to 90 GHz
S93093BSpectrum Analysis up to 125 GH
S93094BSpectrum Analysis up to and beyond 125 GHz
S93118BFast CW measurements
S93460BTrue-mode stimulus
S93551BN-port measurements
S93898BBuilt-in performance test software
S930317BPhase noise measurement up to 70 GHz
S930321BPhase noise measurement up to 125 GHz
S930700BModulation distortion up to 8.5 GHz
S930701BModulation distortion up to 13.5 GHz
S930702BModulation distortion up to 26.5 GH
S930704BModulation distortion up to 43.5 GHz
S930705BModulation distortion up to 50 GHz
S930707BModulation distortion up to 70 GHz
S94601BDevice measurement eXpert - DM
S94602BLimit assistant
Accessories
U8488APower Sensor; USB average thermocouple, 10MHz-67GHz
N5227B-1CMRack mount kit for installation without handles
N5227B-1CPRack mount kit for installation with handles
N1966APulse/IO Adapter
N1671AMATLAB Software
N5227B-SSDAdditional removable solid state drive



FAQ:


1. Can you ship the order to Canada or Australia?
Yes, we can. We send orders worldwide.


2. What delivery method do you use ? and delivery time?
We can ship by EMS, DHL, FedEx, UPS, and TNT with tracking numbers. The usual delivery time is 4-7 workdays.


3. What is your payment term?
100% T/T payment before shipment.


4. How can I ask any other question?
You can contact us online or leave us messages below.


China Keysight N5227B PNA Microwave Network Analyzer 10 MHz To 67 GHz supplier

Keysight N5227B PNA Microwave Network Analyzer 10 MHz To 67 GHz

Inquiry Cart 0