YSR6-12 SF6 Insulated RMU Medium Voltage Ring Main Unit MV&HV Switchgear

Brand Name:Eberry
Model Number:YSR6-12/24/40.5
Minimum Order Quantity:1 set
Delivery Time:5-8 work days
Payment Terms:L/C, D/A, D/P, Western Union, Western Union, MoneyGram
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Address: 66 pu nan Road, Yueqing Economic Development Zone, Zhejiang, China
Supplier`s last login times: within 40 hours
Product Details Company Profile
Product Details

Our Catalogue


  1. Based on international advanced concepts, with world-class production,testing methods,laser welding,laser cutting and hellumleak detection equipment;
  2. The primary components of the product are fully sealed in stainless-steel-plate-welded sealed gas tank, filed with SF6 gas at acertain pressure as the insulating medium, and its protection grade is lP67 to prevent any influence from external environmentsand climate to the switchgear cabinet: it can run reliably in basement, plateau, tundra, coastal, humid and other harshenvironments without maintenance.
  3. The product can be actuated manually or electrically, and the actuator is mature and reliable with complete mechanical andelectrical interlocks to effectively prevent personal injury and equipment damage due to any error in operation.
  4. The product is compact, compared with traditional air-insulated switchgear, it is significantly smaller and the floor area occupiedis less by 30%-70% to improve space utilization efficiency and effectively reduce comprehensive engineering cost.The protection and system technology based on microprocessor combines protection, control, metering, detection andcommunication functions to make the power distribution network automatic and digital without personnel on duty.

ItemUnitParameter
Rated voltagekV12 24 40.5
Rated frequencyHz50
Rated currentA630/1250/2500/3150/4000/630/1250/2500
Power frequency withstand voltage (phase-to-phase and phase-to-ground)kV42 65 95
Power frequency withstand voltage (insulation breaking)kV48 79 118
Lightning impulse withstand voltage (phase-to-phase and phase-to-ground)kV75 125 185
Lightning impulse withstand voltage (insulation breaking)kV85 145 215
Rated power frequency withstand voltage of auxiliary circuitkV2
Rated instantaneous withstand currentkA25/31.5/40
Rated short-circuit periods3
Rated peak withstand currentkA63/80/100 63/80/100 50/63/80
Rated short-circuit breaking current of circuit breakerkA25/31.5/40 25/31.5/40 25/31.5
Rated short-circuit closing current of circuit breaker (peak)kA63/80/100 63/80/100 50/63/80
Rated cable charge breaking currentA25
Rated operating sequenceO-0.3s-CO-3min-CO
Insulation gasSF6
Mechanical lifeTime10000
Three-position switchTime5000
Rated charge pressure (abs, 20°C)Mpa0.14
Minimum charge pressure (abs, 20°C)Mpa0.12
Sealed enclosureGradeIP67
Switch shellGradeUP4X
Annual relative leak rate of dry air%/year≤0.1
Rated power voltage of auxiliary circuitVDC48/110/220 AC220