LM25056PSQ/NOPB Power Regulator IC Current & Power Monitors & Regulators System Power Measurement IC
FEATURES
I2C/SMBus Interface with PMBus Compliant Command Structure
Remote Temperature Sensing with Programmable Warning and Shutdown Thresholds
Real Time Monitoring of VIN, IIN, PIN, VAUX with 12-bit Resolution and 1 kHz Sampling Rate
True Input Power Measurement Using Simultaneous Sampling of VIN and IIN Accurately Averages Dynamic Power Readings
Averaging of VIN, IIN, PIN, and VAUX Over Programmable Interval Ranging from 0.001 to 4 Seconds
User Programmable WARN and FAULT Thresholds with SMBA Notification
Black Box Capture of Telemetry Measurements and Device Status Triggered by WARN and FAULT Conditions
APPLICATIONS
• Server Backplane Systems
• Base Station Power Distribution Systems
• Subsystem Power Measurement
Full Featured Application Development Software
WQFN-24 Package
DESCRIPTION
The LM25056 combines high performance analog and digital technology with a PMBusTM compliant SMBusTM/I2C interface to accurately measure the operating conditions of electrical systems including computing and storage blades connected to a backplane power bus. The LM25056 continuously supplies real-time power, voltage, current, and temperature data to the system management host via the SMBus interface.
The LM25056 monitoring block captures both real- time and average values of subsystem operating parameters (VIN, IIN, PIN, VAUX) as well as peak power. Accurate power measurement is accomplished by measuring the product of the input voltage and current through a shunt resistor. LM25056 current measurement has a ±1.5% accuracy over the temperature range of -40°C to +85°C with operation from -40°C to +125°C. A black box (Telemetry/Fault Snapshot) function captures and stores telemetry data and device status in the event of a warning or a fault.