Add to Cart
Black Foam Size 5*5cm Tube Pad Adhesive Film Npwt Negative Pressure Wound Therapy Medical Dressing Set
Product Introduction
【Structure and composition】The micro-negative pressure drainage tube protection material set is composed of absorbent fiber, drainage tube and semi-permeable membrane. The absorbent fiber is made of polyurethane material, the semi-permeable membrane is made of polyurethane material, and the drainage tube is composed of medical polyurethane, silicone rubber or polyvinyl chloride.
【Functional indications/indications】The product is suitable for all stages of the wound, especially for all kinds of wounds with medium and high exudation; Burn plastic skin grafting, wounds in the donor area; various surgical incisions and wounds such as trauma; burn wounds; various types of ulcers and other difficult-to-heal wounds; pressure ulcer prevention; Prevention of all types of infected wounds and wound infections.
specification: (Length: 5 ~ 60cm) *( width :5 ~ 45cm) *( thickness: 0.6 ~ 4.0cm) (straight tube type, suction cup type)
Main performance indexes:
Products should be sterile;
For other main performance indicators, please refer to product
technical requirements.
4.1 Medical foam
4.1.1 PVA foam: Honeycombed, with good three-dimensional structure and space, good
permeability and water permeability, strong resilience and good
biocompatibility. Physical properties: shrink and harden when the product is dry.
Therefore, compared with PU foam, PVA foam is more suitable for wounds with more acute secretions with high
negative pressure drainage.
4.1.2 PU foam: Composed of numerous filaments, the three-dimensional network is
better in three-dimensional structure and space than PVA foam, and the density is only 1/3--1/5 of PVA foam. More breathable and permeable, excellent biocompatibility.
Compared with PVA foam, PU foam is more suitable for the negative pressure sealing treatment of
wounds with less dryness of various secretions and chronic
refractory wounds.
4.2 porous suction tube
Silica gel material, cloth into the foam to enhance the drainage effect, strong compression resistance,
according to the width and length of the foam to determine the number of porous suction tube and tube arrangement
mode.
4.3 Porous flushing tube
Silica gel material, cloth into the foam to play the role of washing the wound surface, according to the
width and length of the foam to determine the number and mode of porous suction tube.
4.4 Non-perforated connection tube
PVC or silica gel material, one end is connected with the flush tube installed in the foam through the corresponding specification of the joint, and the other
end is connected with the guide tube through the corresponding specification of the joint.
4.5 Transparent breathable adhesive membrane
Pasting is an important material for wound closure, and the pasting
process is also a key step. If wound closure and leakage directly
affect the therapeutic effect of negative pressure sealing and
drainage. According to different types and specifications of
protecting and creating materials, different types and
specifications of laminating membrane can be configured. See
instructions for details.
4.6 Suction connection tube
4.6.1 Universal suction connection tube: both ends of the connection tube are 6-7mm interfaces, which can be connected with 6-7mm universal
joints.
4.6.2 Special suction connection tube: one end can be connected with the negative pressure bottle of
intelligent wound negative pressure comprehensive treatment
instrument produced by our company, and the other end can be
connected with the universal joint with a diameter of 6-7mm.
4.7 Trapezoidal
4.7.1 4×6 Trapezoidal joint: 4mm joint at one end connected to suction connection tube on foam, the other end of the 6mm joint is connected to the suction
connection tube of the negative pressure bottle.
4.7.2 4×4 Trapezoidal joint: It is used to connect the same interface 4mm suction connection tube at both ends, and it is often used to extend the thin suction
connection tube with large wound surface.
4.8 Sucker joint
4.8.1 PU foam suction cup connector: see PU foam operation manual.
4.8.2 PVA foam suction cup connector: see PVA foam operation manual.
4.9 Y-joint
4.9.1 4×4×4 Y-joint: Connect three 4mm tubes of the same type, usually changing from 2 to 1.
4.9.2 4×4×6 Y-joint: Connect two 4mm tubes with one 6mm tube.
4.10 Check hydraulic clamp
Install a stop clip on each suction connection tube above the sea surface and open or close a single tube when necessary.
Sterilization method: Radiation sterilization is adopted
Determine where the suction cup fittings will be placed on the foam
and where the porous contacts will be.
The perforated irrigation tube was inserted into the sponge wound
at an angle of 30-45 degrees to the sponge suction surface for
intermittent fixation. If the wound has sinus tracts and deep
cavities, a sponge can be incised along the perforated irrigation
tube for negative pressure therapy.
With the suction cup as the center, the entire wound surface is
sealed with a special film made of PU sponge suction cup.
After connecting with negative pressure, the wound was checked to
have no air leakage, and the wound pipeline was cleaned
unobstructed under negative pressure.
8.6.2 PVA foam suction cup sealing method:
After cutting the foam, place it on the wound surface and seal it
with PVA suction cup special membrane. First, let the flush tube
interface on the suction cup go through the corresponding hole of
the membrane, and then let the suction tube interface go through
successively. Let the membrane stick close to the root of the flush
tube and the suction tube, and then peel off the core paper from
the upper and lower membrane of the suction cup and paste the fixed
suction cup and foam respectively. The special adhesive membrane is
closed from the center of the suction cup to the other end of the
foam, and then the adhesive membrane is set under the suction cup
interface and overlapped with the above adhesive membrane by
cutting two notch, and the other end of the foam is closed
downward.
After cutting the foam, place it on the wound surface and seal it
with PVA suction cup special membrane. First, let the flush tube
interface on the suction cup go through the corresponding hole of
the membrane, and then let the suction tube interface go through
successively.
Let the membrane stick close to the root of the flush tube and the
suction tube, and then peel off the core paper from the upper and
lower membrane of the suction cup and paste the fixed suction cup
and foam respectively.
Tube connection:
Y-joint, trapezoidal joint are used to connect various suction
tubes in the medical foam according to functions.
1.What is advantage on quality?
The company is furnished with developed equipment and technology
from Germany, Belgium, and Taiwan (area).
2. What is MOQ?
30,00 pcs, It depends on requirements of products.
3. How to place a order?
Place order with salesperson
Make payment for deposit;
Sample making for confirmation before mass production;
After sample confirmed, mass production start;
Goods are finished,inform buyer to make payment for balance;
Delivery.
Production time : 30-40 days.
4. What is your term of payment?
T/T is a regular payment (30% in advance, 70% before shipping).
Paypal and Western Union are just for a sample