How does a chiller system work?

The chiller operates with two circulations: one involves the circulation of process water, while the other entails the circulation of refrigerant gas. Heat absorbed from the process is transferred to the refrigerant circulation, and then expelled to either air or water.


Technical Parameters of Industrial Air-cooled Chiller

Model
Item

ACK-30(D)
nominal cooling capacitykcal/h95357
kw110.88
input powerkw29.92
power supply3PH 440V 60Hz
refrigeranttypeR407C
type of controlthermostatic expansion valve
compressortypehermetic scroll
power(kw)24.92
condensertypefinned copper tube + low noise outer rotor fan
cooling air flow(m3/h)40000
evaporatortypeshell and tube
chilled fluid flow (m3/h)19.12
volume (L)240
inlet and outlet pipe diameter (inch)2-1/2
pumppower(kw)2.2
lift(m)20
safety protectioncompressor overheating protection, over-current protection, high and low pressure protection, over-temperature protection,flow switch protection, phase sequence or missing phase protection, exhaust overheating protection
weightkg1300
dimensionmm2300*1480*1900

Note: The nominal cooling capacity is according to: Inlet chilled fluid temperature: 17℃,outlet chilled fluid temperature: 12℃.


Air Cooled Water Chiller:

The air cooled industrial chiller, also known as an air-cooled box-type industrial chiller cooling unit, utilizes a air-cooled heat dissipation design. It draws surrounding air into the equipment using built-in fans and dissipates heat through a condenser, thereby reducing the system temperature. It does not require an additional water cooling system and is relatively easy to install and maintain.

Working Principle of SZAGS Water Chiller:

When the air cooled chiller starts, the refrigerant absorbs the heat from the cooled object in the evaporator and vaporizes. The compressor continuously extracts the generated gas from the evaporator and compresses it into high-temperature, high-pressure vapor. The refrigerant vapor is then sent to the condenser, where it undergoes heat exchange with the air. After releasing heat, it condenses into a liquid. The liquid refrigerant, after being depressurized by the expansion valve, enters the evaporator where it vaporizes again, absorbing heat from the cooled object. This heat exchange process is repeated until the industrial water is cooled to the desired temperature.

Application of SZAGS Chiller :

1. Plastic Industry: Water chiller can be used for cooling plastic injection and extrusion molding machines to reduce molding cycle time and improve product quality.
2. Electronics Industry: Industrial chiller provides consistent cooling for electronic components and equipment, ensuring stable performance and preventing overheating.
3. Printing Industry: Anges chiller helps in maintaining precise temperature control for ink and rollers, enhancing print quality and reducing downtime.
4. Food & Beverage Industry: Cooler utilized for cooling liquids and food processing equipment, ensuring freshness and quality in production lines.
5. Pharmaceutical Industry: Controls the temperature during drug production and storage, maintaining product stability and ensuring compliance with safety standards.
6. HVAC Systems: Used for air conditioning in commercial buildings, hospitals, and large facilities, ensuring a comfortable environment.
7. Laser Industry: Provides cooling for laser cutting and engraving machines, ensuring optimal performance and longevity of the equipment.
8. Chemical Industry: Regulates the temperature during chemical reactions and processes, ensuring safe and efficient production.

Installation&Maintenance of SZAGZ Chiller

Maintenance: Air-cooled chillers eliminate the need for cooling towers and no need water treatment, chiller condenser-tube cleaning, tower mechanical maintenance.
Installation: Most of the air-cooled chillers are packed systems which are including the air-cooled finned condenser, evaporator compressor and evaporator.Some of them are built-in water storage tank and pump,they are designed and configured at the factory for optimal performance and reliability, which reduces design and simplifies installation.