Add to Cart
LED Explosion Proof Light Plug and Socket CZ81
Copper free aluminum explosion-proof enclosure.
Plastic-sprayed surface.
Three types of enclosures optional.
Plugs shall be only pulled out when switch is off;turn on the power after inserting the plug.
Degree of protection:IP66/IP67
ORDERING GUIDE
Marking ATEX
Ⅱ 2 G Ex db ⅡC T6 Gb
Ⅱ 2 D Ex tb ⅢC T80℃ Db IP66/IP67
Marking IECEx
Ex db ⅡC T6 Gb
Ex tb ⅢC T80℃ Db IP66/IP67
Marking UL1203
Class I, Division 1, Groups B, C, D
Class I, Division 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
Standard
EN 60079-0, EN 60079-1, EN 60079-31; IEC 60079-0, IEC 60079-1, IEC 60079-31
Socket Cable Entry
EX-CZ81-16: 2×M25×1.5(3P/4P), 2×M32×1.5(5P); EX-CZ81-32: 2×M32×1.5
Plug Cable Entry
EX-CZ81-16: 1×M25×1.5(3P/4P), 1×M32×1.5(5P); EX-CZ81-32: 1×M32×1.5
Cable Cross-sectional Area
EX-CZ81-16: 2.5 mm²~4 mm²; EX-CZ81-32: 4 mm²~6 mm²
Ambient Temperature:-60℃ to +55℃
Voltage | Current | Pole number | H |
AC:100-130V | 16A | 2P+E | 4 |
AC:200-250V | 6 | ||
AC:100-130V | 3P+PE | 4 | |
AC:200-250V | 9 | ||
AC:380-415V | 6 | ||
AC:480-500V | 7 | ||
AC:600-690V | 5 | ||
AC:57/100-75/130V | 3P+N+PE | 4 | |
AC:120/208-144/250V | 9 | ||
AC:200/346-240/415V | 6 | ||
AC:277/480-288/500V | 7 | ||
AC:347/600-400/690V | 5 |
Voltage | Current | Pole number | H |
AC:200-250V | 32A | 2P+PE 3P+PE | 6 |
AC:200-250V | 9 | ||
AC:380-415V | 6 | ||
AC:480-500V | 7 | ||
AC:600-690V | 5 | ||
AC:120/208-144/250V | 3P+N+PE | 9 | |
AC:200/346-240/415V | 6 | ||
AC:277/480-288/500V | 7 | ||
AC:347/600-400/960V | 5 |
Copper free aluminum explosion-proof enclosure.
Plastic-sprayed surface.
Three types of enclosures optional.
Plugs shall be only pulled out when switch is off; turn on the power after inserting the plug.
Marking ATEX
Ⅱ 2 G Ex db ⅡC T6 Gb
Ⅱ 2 D Ex tb ⅢC T80℃ Db IP66/IP67
Marking IECEx
Ex db ⅡC T6 Gb
Ex tb ⅢC T80℃ Db IP66/IP67
Marking UL1203
Class I, Division 1, Groups B, C, D
Class I, Division 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
Standard
EN 60079-0, EN 60079-1, EN 60079-31
IEC 60079-0, IEC 60079-1, IEC 60079-31
Ambient Temperature:-60℃ to +55℃
Rated Voltage:See the Table Below
Rated Current:63A
Degree of Protection:IP66-IP67
Socket Cable Entry:2×M40×1.5
Plug Cable Entry:1×M50×1.5
Cable Cross-sectional Area:10mm²~16mm²
Voltage | Current | Pole number | H |
AC:200-25-V | 63A | 3P+PE | 9 |
AC:380-415V | 6 | ||
AC:480-500V | 7 | ||
AC:600-690V | 5 | ||
AC:200/346-240/415V | 3P+N+PE | 6 | |
AC:277/480-288/500V | 7 |
FEATURES
Copper free aluminum explosion-proof enclosure.
Plastic-sprayed surface.
Three types of enclosures optional.
Plugs shall be only pulled out when switch is off; turn on the power after inserting the plug.
Marking ATEX
Ⅱ 2 G Ex db ⅡC T6 Gb
Ⅱ 2 D Ex tb ⅢC T80℃ Db IP66/IP67
Marking IECEx
Ex db ⅡC T6 Gb
Ex tb ⅢC T80℃ Db IP66/IP67
Marking UL1203
Class I, Division 1, Groups B, C, D
Class I, Division 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
Standard
EN 60079-0, EN 60079-1, EN 60079-31
IEC 60079-0, IEC 60079-1, IEC 60079-31
Ambient Temperature:-60℃ to +55℃
Rated Voltage:See the Table Below
Rated Current:125A
Degree of Protection:IP66-IP67
Socket Cable Entry:1×M63×1.5
Plug Cable Entry:1×M50×1.5
Cable Cross-sectional Area:25mm²~35mm²
Voltage | Current | Pole number | H |
AC:200-25-V | 125V | 3P+PE | 9 |
AC:380-415V | 6 | ||
AC:480-500V | 7 | ||
AC:600-690V | 5 | ||
AC:200/346-240/415V | 3P+N+PE | 6 | |
AC:277/480-288/500V | 7 |