

Add to Cart
280T/H Floor-standing Immunoassay Analyzer 15min for First Result Fully Automated Used in Hospital CLIA
Features:
1. Advanced detection principle
The magnetic particle separation chemiluminescence method adopts
the current two mainstream immunoassay cutting-edge technologies in
the world-magnetic particle carrier technology and
chemiluminescence detection technology, which broadens the linear
range of detection, improves detection sensitivity and analysis
speed, and enables the system to fully meet clinical needs.
Requirements for test results.
2. Strong detection throughput
Detection speed: 280T/H.
One-step and two-step on-machine testing at the same time.
The first result can be detected in as fast as 15 minutes,
realizing the fastest detection.
3. Stable detection system
Reliable traceability system, traceability to international level
professional data processing, intelligent management of calibration
quality control with various calibration curve fitting methods,
independent judgment of effectiveness.
4. Unique FITC/anti-FITC bridge technology
The superparamagnetic particles are used as the solid phase of the
reaction, so that the reaction is more and sufficient, and it is
easy to separate the alkaline phosphatase as the labeled enzyme.
Compared with HRP, the background value is lower and the
sensitivity is higher. It has advanced small molecule labeling
technology to enhance the detection accuracy of small molecules.
5. Innovative AP-APLS chemiluminescence technology
High detection sensitivity, wide linear range, single-component
substrate, strong stability, easy to use
Novel APLS luminescent substrate. The reaction plateau is reached
quickly within 20s, the signal is continuously stable, easy to
detect, avoid direct labeling of luminescent substances, not
interfered by oxidants, and the signal is more stable.
Model | Automated Immunoassay Analyzer CIA2800 | |
Overall Performance | Throughput | 280 Tests/hour |
Repeatability | CV≤8% | |
Sample & Reagent System | Sample Positions | 96 sample positions |
Reagent Position | 26 reagent positions | |
Probe Washing | Automatic washing interior and exterior | |
Reagent Cooling | Refrigerated tray with independent switch | |
Reaction System | Temperature Control | 37+0.1℃, real-time monitoring |
Position | 145 | |
Mixer Probe | Independent stirring | |
Calibration | Calibration | 2/6-point |
Data Management | Software | Touch screen, English operation interface |
Thyroid | TSH |
TT3 | |
TT4 | |
FT3 | |
FT4 | |
TGAb | |
TPOAb | |
TRAb | |
TG | |
Fertility | FSH |
PRL | |
LH | |
E2 | |
TESTO | |
PROG | |
HCG | |
P/H-hcg | |
AMH | |
Glycometabolism & Hypophyseal Hormone | C-P |
INS | |
Hepatic Fibrosis | PIIINP |
HA | |
LN | |
CIV | |
Tumor Markers | CEA |
AFP | |
CA125 | |
CA19-9 | |
CA15-3 | |
CA50 | |
CA72-4 | |
CA242 | |
T-PSA | |
F-PSA | |
TK1 | |
FERRITIN | |
SCC | |
NSE | |
CYFRA21-1 | |
HE4 | |
S100 | |
Hp-Ab | |
TPS | |
TNF-α | |
GP73 | |
PIVKAⅡ | |
PACP | |
Inflammation Monitoring | IL-6 |
PCT | |
CRP | |
CAA | |
Cardiac | cTn |
MYO | |
CK-MB | |
HFABP | |
NT-pro-BNP | |
D-Dimer | |
HCY | |
BNP | |
Lp-pla2 | |
ST2 | |
TORCH | |
Infectious | HBsAg |
HBsAb | |
HBeAg | |
HBeAb | |
HBcAb | |
Anti-HCV | |
Anti-HIV | |
Anti-TP | |
NP-IgG | |
NP-IgM | |
Kidney Function | NGAL |
H-ALB | |
RBP | |
Cys-C | |
β2-MG | |
Gastric Mucosa Function | PGⅠ/Ⅱ |
PRO-GRP | |
GRP-17 |