Tylosin Tilmicosin Combo Milk Test Kit Rapid Test Strip 96 Tests/Kit

Brand Name:Green Spring
Certification:ISO13485,ISO9001
Model Number:LSY-20112
Minimum Order Quantity:1kit
Delivery Time:7~14days
Payment Terms:T/T
Contact Now

Add to Cart

Active Member
Location: Shenzhen
Address: Vanke Tianyu Garden,B2-1010, Unit B, Building 9 Longcheng Street Longgang District Shenzhen, China
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

Tylosin Tilmicosin Combo Rapid Test Strip for Milk 96 Tests/Kit


1. Specifications


8 strips/bottle, 12 bottles/kit


2. Brief


The Tylosin-Tilmicosin rapid test strip is used for testing Tylosin and Tilmicosin residue in milk(including pure milk and fresh milk) and goat milk qualitatively. The whole test only need 6min, east to operate with high sensitivity.


3. Detection limit


NameDetection limit ppb(ug/kg)
Tylosin2-3
Tilmicosin3-5

4. Tylosin Tilmicosin Combo Rapid Test Strip Contents


Tylosin-Tilmicosin test strip8strip/bottle
Red powder micro-well8 micro-well/bottle
Desiccant2piece/bottle
Instruction1 piece

5. Tylosin Tilmicosin Combo Rapid Test Strip Principle


The Tylosin-Tilmicosin rapid test strip is based on competitive inhibition immuno-chromatographic principle. In the flow process, Tylosin-Tilmicosin in the sample combined with Tylosin-Tilmicosin specific colloidal gold-labeled monoclonal antibody, Inhibit the combination between antibody and Tylosin-Tilmicosin-BSA conjugate on Test line of NC membrane, lead to the color change of Test line. When the sample has no Tylosin-Tilmicosin residue or concentration lower than detection limit, T line is darker then C line; when the concentration is equal to or higher than detection limit, T line is lighter than C line or T line has no color or T line has same color with C line. No matter whether there is Tylosin-Tilmicosin residue in sample, C line will appear, it means the test is valid.


6. Operation procedures


6.1 Please read the manual carefully before use. Return ready-to-use test strips and samples to room temperature.
6.2 Take out the required bottle from the kit, take out the required microwell, mark it accordingly, please use it within 1 hour. To avoid moisture, please seal the lid.
6.3 Use a micropipette to take 200ul of the sample into the microwell, repeat the aspiration 5 times, and mix the sample with the reagent in the microwell until there are no solid particles visually judged (this is a very important step).
6.4 Incubate at 40±2°C for 3 minutes. Then insert the test strip into the microwell and place the end with the MAX in the liquid.
6.5 Insert the test strip into the liquid for 3 minutes and read the result.


7. Test Result Interpretation


Color depth comparison of T line and C lineResult judgmentResult analysis
T line > C lineNegativeTylosin-Tilmicosin residue is lower than detection limit in sample
T line = C lineWeak positiveTylosin-Tilmicosin residue is equal to detection limit in sample
T line < C line or T line is invisiblePositiveTylosin-Tilmicosin residue is higher than detection limit in sample
C line is invisibleInvalidThe test strip is invalid, test again


8. Precautions


1) Use the test strip once at room temperature, do not use expired test strips.
2) Cap the bottle immediately after removing the reagent. If the 8 micro-holes cannot be used up at one time, please cover the micro-holes immediately, put them back in the bottle, and store them in an airtight container.
3) Do not touch the white film surface in the middle of the test strip, avoid direct sunlight and direct blowing of fans.
4) The milk sample should be completely liquid without any lumps, sourness and sedimentation.
5) Use the test strip again for a positive result.


9. Specificity


This product has no cross-reaction with Quinolones, Sulfonamides and Tetracyclines etc.


10. Storage and expiry date


Storage: Store at 2-8 ℃ in dark, sealed, dry place, no frozen.
Expiry date: 12 months; date of production is on box.



Q1: When will it be shipped?
A1: We will ship the goods for you as soon as possible within 7 working days after receiving the payment. (In case of external factors such as the epidemic, the delivery may be delayed)


Q2: Does it support OEM/ODM?
A2: It can be supported, but the specific quantity needs to be more than 100,000 pieces, which is convenient for customized products.


Q3: How is your factory doing in terms of quality control?
A3: We have nationally certified ISO9001 and ISO13485. Our production process conforms to standard procedures to ensure optimum product quality.


Q4: How to provide after-sales service?
A4: We provide professional online technical after-sales service. We can provide you with one-on-one guidance via video, telephone, etc.


Q5: What is the payment method?
A5: We receive payment by T/T.


Q6: How to ship?
A6: Choose the best shipping method for you by getting quotes from our many cooperative carriers, and also ship according to your requirements.

China Tylosin Tilmicosin Combo Milk Test Kit Rapid Test Strip 96 Tests/Kit supplier

Tylosin Tilmicosin Combo Milk Test Kit Rapid Test Strip 96 Tests/Kit

Inquiry Cart 0