1000Kw 380 Volt Electric Heater Boiler Electromagnetic Heating For Winter

Brand Name:lincheng
Model Number:LC-L-1000kw
Minimum Order Quantity:discussible
Delivery Time:3-10 working days
Payment Terms:L/C, T/T
Place of Origin:Shenyang, Liaoning, China
Contact Now

Add to Cart

Active Member
Location: Shenyang Liaoning China
Address: 20-1 Jiayang Road, Shenbei New District, Shenyang, Liaoning
Supplier`s last login times: within 27 hours
Product Details Company Profile
Product Details

Electric Heater Boiler:1000Kw Heating Area: 12000㎡-17000㎡ Electric Heating Boiler In Factory Workshop In Winter


To Ensure The Safe Use Of Electric Heater Boiler, The Following Four Points Must Be Achieved During Installation

1: Match appropriate wires

According to the power of electromagnetic heating furnace, the calculation formula of power line thickness is as follows: current calculation formula: current = power (watt) 3801.732, and the calculation formula of wire specification is: current U 4 electromagnetic heater

2: Installation of leakage protector

What is the use of leakage protector? In short, it can protect people from electric shock, overload and short-circuit protection in case of leakage fault of equipment, can be used to protect the overload and short-circuit of lines or motors, and can also be used as infrequent switching and starting of lines under normal conditions. When selecting, try to choose products with large brands and guaranteed quality.

3: Connect the ground wire

Generally speaking, farmers who turn coal into electricity do not have grounding wires at home, so how to solve this problem can be completed with grounding pins. The grounding wire must be connected before use. Because the ground wire is the last protective barrier.

4: Pay attention to the height of the water outlet.

After the wires are connected, the waterway can be installed. Generally speaking, the installation of waterways is relatively simple, but please remember that the pipes of water bucket, water pump and heating furnace cannot be installed incorrectly. Here is an important note: the water pump must be installed at the return port of the electromagnetic heating furnace (which is different from the coal-fired boiler). The water bucket must be installed at the inlet of the water pump. The outlet height of the radiator must be slightly higher than the outlet height of the electromagnetic heating furnace, and there must be a certain slope, which is conducive to the discharge of air in the radiator.


Electric Heater Boiler Technical Parameter:

Serial numberProduct modelCompanyLC-L-1000kw
1Rated powerKW1000
2Rated currentA1520
3Heating area10000-15000
4input voltage50HZ380V
5Minimum flow of water pump configurationL/min1800
6Hot water yield 50 ℃L/min468
7Design thermal efficiency98%
8Maximum water temperature85
9Low temperature protection temperature5
10Overall dimension (length * width * height)mm4600L*1200W*2000H
11Water inlet and outlet interfaceDN125

Connection Mode Of Electric Heater Boiler:

1. Carbon steel pipes, hot-dip galvanized steel pipes or PPR pipes can be used for heating pipes.

2. The heating medium is ordinary tap water or purified water, with water supply temperature of 60-80 ℃ and return water temperature of 40-50 ℃.

3. During the laying of heating pipes, a certain slope shall be maintained. The hot water pipes with the same flow of air and water shall not be less than 0.003, the hot water pipes with the reverse flow of air and water shall not be less than 0.005, and the branch pipes connected with the radiator shall not be less than 0.01

4. The pipeline is connected by thread or hot melt.


China 1000Kw 380 Volt Electric Heater Boiler Electromagnetic Heating For Winter supplier

1000Kw 380 Volt Electric Heater Boiler Electromagnetic Heating For Winter

Inquiry Cart 0