Product Details
NH3-B1 Four Electrode Electrochemical Ammonia Sensor
Electrochemical Gas Sensor For Detect The Concentration Of Ammonia
In The Atmosphere Linear Current Output Easy Signal Processing
NH3-B1 Ammonia Sensor NH3 Sensor Description
Alphasense is expanding its line of electrochemical toxic gas
sensors to address industry-specific requirements, including
emissions monitoring, process safety, environmental monitoring and
VOCs.
Ammonia (NH3)
Our first family of Ammonia sensors. This sensor is designed for
higher concentrations of Ammonia. Sensors for lower level detection
are in development.
NH3-B1 Ammonia Sensor NH3 Sensor PERFORMANCE |
Sensitivity | nA/ppm in 50ppm NH3 | 25 to 45 |
Response time | t90 (s) from zero to 50ppm NH3 | <60 |
Zero current | ppm equivalent in zero air | < ± 7 |
Resolution | RMS noise (ppm equivalent) | <0.3 |
Range | ppm NH3 limit of performance warranty | 100 |
Linearity | ppm error at full scale, linear at zero and 20ppm NH3 | +5 to -5 |
Overgas limit | maximum ppm for stable response to gas pulse | 200 |
| |
NH3-B1 Ammonia Sensor NH3 Sensor LIFETIME |
Zero drift | ppm equivalent change/year in lab air | <2 |
Sensitivity | drift % change/year in lab air, monthly test | <3 |
Operating life | months until 80% original signal (24 month warranted) | >24 |
NH3-B1 Ammonia Sensor NH3 Sensor ENVIRONMENTAL |
Sensitivity @ -20°C | % (output @ -20°C/output @ 20°C) @ 20ppm | ND |
Sensitivity @ 50°C | % (output @ 50°C/output @ 20°C) @ 20ppm | ND |
Zero @ -20°C | ppm equivalent change from 20°C | ND |
Zero @ 50°C | ppm equivalent change from 20°C | ND |
NH3-B1 Ammonia Sensor NH3 Sensor CROSS SENSITIVITY |
H2S sensitivity | % measured gas @ 20ppm H2S | <300 |
NO2 sensitivity | % measured gas @ 20ppm NO2 | <-300 |
Cl2 sensitivity | % measured gas @ 10ppm Cl2 | <-300 |
NO sensitivity | % measured gas @ 50ppm NO | ND |
SO2 sensitivity | % measured gas @ 20ppm SO2 | ND |
CO sensitivity | % measured gas @ 400ppm CO | <20 |
H2 sensitivity | % measured gas @ 400ppm H2 | <15 |
C2H4 sensitivity | % measured gas @ 400ppm C2H4 | ND |
CO2 sensitivity | % measured gas @ 5% CO2 | ND |
NH3-B1 Ammonia Sensor NH3 Sensor KEY SPECIFICATIONS |
Bias voltage | mV (Working Electrode potential is above ground) | +200 |
Temperature range | °C | -30 to 50 |
Pressure range | kPa | 80 to 120 |
Humidity range | % rh continuous | 15 to 90 |
Storage period months | @ 3 to 20°C (stored in sealed pot) | 6 |
Load resistor | Ω (recommended) | 10 to 47 |
Weight | g | <13 |
Company Profile
Yijiajie Electronics is a full range of silicon pressure sensors
from the United States, FREESCALE/, GE, MEAS, SMI, and a full range
of sensing and control products from the United States pressure,
temperature and humidity, gas flow, current, Hall effect, etc.,
Japan HAMAMATSU flame, UV sensors, photodiodes, Japan FIGARO, UK
CITY, ALPHASENSE full range of semiconductors, catalytic,
electrochemical gas sensors, French HUMIREL/MEAS humidity sensors
and other international well-known companies authorized agents or
distributors, to provide customers with product information,
products Solutions, product selection, supply guarantee and
logistics services, etc.