

Add to Cart
Used in OT lift
Unlimited times Using
Have good quality and common quality difference, the biggest difference is the keypad.
Details for Otis Elevator Black Test Service Tool GAA21750S1
Brand | OT |
Description | Elevator Service Tool |
Part No. | GAA21750S1 |
MOQ | 1PC |
Transportion | TNT, UPS, DHL, Fedex, Air, Sea |
Applicable | Elevator |
Packages | Carton, Wooden case, Pallet etc |
Delivery Time | Normally 2-3 working days after payment |
Warranty | One year |
Payment Method | Company Bank, Western union, alibaba, Paypal, Personal bank etc |
Pictures for Otis Elevator Black Test Service Tool GAA21750S1
The server uses:
After inserting the server into the port of the Otis elevator
board, the ST display will firstly display: SELF TEST –OKMECS-MODE,
which means: the server has passed the self-test, and the current
connection is the modular elevator control system mode, so that The
display is normal. If other words appear, please unplug the
debugger and re-insert it in the experiment. If the problem cannot
be solved, then the debugger or elevator components may be faulty.
Otis elevator server operation method
Procedures for Otis machine roomless elevators and machine room
elevators and server operation methods for checking faults and
other content
Check the main board for elevator system failure: LCB2, LMCB,
ALMCB, HAMCB
M-1-2-1 Clear the fault record: in the fault record menu, press the
blue key + 2, and press the prompt to confirm. Drive: M-3-2-1
Current elevator fault M-3-2-2 Historical fault record M-3-2-3
Clear
Current elevator fault M-3-2-4 Clear historical fault record
Mainboard: GECB, TCBC M-1-1-2-1 Fault record clear: In the fault
record menu, press the blue key +2, and press the prompt to
confirm.
Drive: M-2-2-1 record M-2-2-2 historical fault record M-2-2-4 clear
historical fault record
Current elevator fault M-2-2-2 History fault record M-2-2-3 Clear
current elevator fault
M-2-2-5 Reset the inverter (equivalent to power-off reset)
Mainboard: RCB2+MCB / OSBA+MSBA OCSS: Key sequence: M-1-2-2-1:
Event record M-1-2-2-2: Operation mode record Clear fault method:
Clear single fault, please use ST Press SHIFT+ENTER while the
record is displayed to clear the fault in the display. If all fault
records are clear, please press SHIFT+5 and then follow the above
prompts to confirm. Or press M-1-5-1 to clear the fault MCSS: key
sequence: M-2-2-2: event record clear fault method: same as the
above OCSS drive: OVF30: key sequence: M-4-2-1: View current faults
M-4-2-2: View storage faults M-4-2-3: Clear fault records Event
record M-2-2-2: View all uncleared fault records before the last
power-on. Fault clearing method: Press SHIFT+5, and then confirm
according to the above prompts to clear.