Home Oximeter Blood Oxygen Saturation Monitor DC 2.6V To 3.6V

Brand Name:THXC
Certification:CE
Model Number:TX-2-OM3
Minimum Order Quantity:100 units
Delivery Time:5-15
Payment Terms:L/C, , T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Location: Chengdu Sichuan China
Address: Block C, Huijin Square, Wuhou District, Chengdu, Sichuan, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Medical Finger Pulse Oximeter With 4 Display Handheld


Product performance description


The measurement range of blood oxygen saturation: 0% ~
100% (resolution is 1%).
Accuracy: 70%-100%: 2%, less than 70%, not specified.
PR measurement range: 30bpm ~ 250bpm, (resolution is
1bpm)
Accuracy: ±2bpm or ±2% (choose larger)
Anti-ambient light: Under artificial light or indoor natural
light conditions, the deviation between darkroom
measurements is less than 1%±.
Power consumption: less than 25mA
Voltage: DC 2.6V ~ 3.6V
Power supply: 1.5V alkaline battery (AAA) * 2
Safety type: internal battery, BF type
Multiple colors available
Function
1)Display of SpO2 value.
2)Display of pulse rate value and bar graph.
3)Display of PI value (optional).
4)Display of pulse waveform.
5)Battery power indication (optional).
6)Low-voltage indication: the low power indication symbol appears when the voltage is too low to work.
7)Auto Power On.
8)Auto standby.
9)The display mode can be changed (optional).
10)Adjustable screen brightness (optional).
11)PR sound prompt (optional).
12)Sound prompt (optional).
13)Automatic direction-changing function (optional).

How to use a oximeter?

1 Install 2 AAA batteries according to the positive and negative
marks in the battery compartment and close the battery cover
2 Open the clamp and put the finger in the measuring area (fully
extend the finger)
3 In the process of use, the tested finger should not pull the human
body and should not be in the state of movement.
4 Read the relevant data directly from the monitor.
During the measurement process, the display direction can be
5 changed once by pressing the key,
There are 6 conversion display directions.


Finger oximetry monitoring of blood oxygen is a non-invasive operation that can effectively monitor blood

oxygen in the body and play a key role in predicting changes in the condition. The normal range for finger

oximetry oxygen saturation is 90%-100%. If it is below 90%, it indicates that the patient is suffering from

severe hypoxia. Also need to pay attention to long-term clamping finger pulse easily due to local compression

or cold weather, and affect the peripheral blood circulation of the finger, resulting in misjudgment, can

be soaked in warm water and then re-monitoring to improve the accuracy of detection. Patients with severe

pneumonia, chronic obstructive pulmonary disease, sleep apnea, and patients with recurrent respiratory

failure can be monitored with finger oximetry.


Product Name
Digital Fingertip Pulse Oximeter
Display Type
OLED display
Display Brightness
1-4 levels can be adjusted
Power by
2 x AAA batteries
SpO2
Measurement range: 70%~99%
PR
Measurement range: 30BPM~240BPM
Power consumption
below 30mA
Operation Environment

Operation Temperature:5℃~40℃
Storage Temperature
-10℃~40℃
Ambient Humidity
15%~80% on operation
Air Pressure
86kPa~106k