Add to Cart
Eltek Inverter Rectiverter 115V/750VA 110V/600W for AC and DC load (241123.140)
Built on HE technology from the Flatpack2 HE rectifier family the Rectiverter 115V/750VA 110V/600W provides backed up power for 115 Vac an 110 Vdc loads with minimum losses and footprint.
The Rectiverter is a 3 port device capable of charging the 110V battery and simultaneously provides power for the AC and DC loads. During mains outage the Rectiverter feeds AC loads using energy stored in the battery.
Parameters :
Models / ordering information 230/1500 230/1500 230/1500 115/750 115/750 115/750 220/1200 220/150 220/0 220/600 220/75 220/0 |
Part number 241123.140 241123.141 241123.142 241123.140L 241123.141L 241123.142L |
AC OUTPUT DATA |
Voltage (default) / (adjustable range) 230 VAC / 200 - 240 VAC 115 VAC / 100 - 127 VAC |
Frequency (default inverter mode) 50 Hz (adaptive) 60 Hz (adaptive) |
Frequency (set-able inverter mode) 50Hz, 60Hz or last synced 50/60Hz (adaptive), 94-106Hz6) |
Power maximum (continuous / overload (<15s) ) 1200 W (1500 VA) / 2000 VA 600 W (750 VA) / 1000 VA |
Load sharing ±5% of active power from 10 to 100% load |
Current maximum (continuous / overload (<15s) ) 6.5 ARMS / 8.7 ARMS |
Current (maximum) Quick trip (20ms) 32 A (6 x nominal) |
THD < 1.5 % at resistive load |
Protection Fuse in L, Hot pluggable, Varistor |
DC OUTPUT DATA |
Voltage (default) / (adjustable range) 245 VDC / 194 - 290 VDC |
Power (maximum @nominal input) 1200 W 1) 150 W 0 W 2) 600 W 1) 75 W 0 W 2) |
Current (maximum @VOUT ≤ 216 VDC) 5.56 A 1) 0.69 A - 2.78 A 1) 0.34 A - |
Hold up time, maximum output power >10ms; VOUT > 190 VDC (only in rectifier mode) |
Current sharing (10 - 100% load) ±5% of maximum current from 10 to 100% load |
Static Voltage regulation (10 - 100% load) ±0.5% |
Dynamic Voltage regulation ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms |
Ripple < 1 VPP , 30 MHz bandwidth |
Protection Short circuit proof, Over voltage shutdown, Reversed polarity and Fuse |
INPUT DATA |
AC Mains Input Voltage (range / LV disconnect) 185 - 275 VAC / 170 VAC 95 - 140 VAC / 85 VAC |
AC Current (maximum) 11.5 ARMS 9.1 ARMS 3) 8.2 ARMS 3) 11.3 ARMS 10.1 ARMS 3) 9.2 ARMS 3) |
Frequency (default: sync range) 47-53 & 57-63 Hz 47-53 & 57-63 Hz |
Frequency (set-able: sync range) 47-53 Hz, 57-63 Hz or both (adaptive) |
Power Factor / THD > 0.99 at 50% load or more / < 3.5% |
AC Input Protection Fuse in L and N, Hot pluggable, Varistor |
DC Voltage nominal / extended range4) 204 - 290 VDC / 180 - 204 VDC |
DC Current (maximum) 6.67 A / 9 A during overload (15s) 3.2 A / 4.5 A during overload (15s) |
OTHER SPECIFICATION |
Efficiency >96% (mains mode (AC/AC and AC/DC)), >94% (inverter mode (DC/AC)) |
Isolation 3.85 kVDC - ACIN/OUT to PE, 3.55 kVDC - ACIN/OUT to DC, 4.25 kVDC - ACIN/OUT to CAN/SYNC, 2.2 kVDC- DC to PE, 3.5 kVDC - DC to CAN/SYNC |
Alarms: Red LED Low and high mains input voltage shutdown, High and low temperature shutdown, Rectiverter Failure, Alarm relay [NO max 75 VDC / 100 mA] Overvoltage shutdown on output, Fan failure, Low output voltage alarm, CAN bus failure, Sync bus (AC output OR DC output alarms) lost and Sync fail |
Warnings: Yellow LED Rectiverter in power de-rate mode or in power or current limit mode on DC or AC port, Remote output current limit activated, Loss of CAN communication with controller |
Normal operation: Green LED AC output and/or DC output on and ok |
Operating temperature -40 to +75°C (-40 to +167°F), humidity 5 - 95% RH non-condensing |
Temperature de-rating above 55°C (131°F) 1200W to 480W @ 75°C (167°F) for each, AC and DC, outputs (total power 2000W to 800W) |
Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing |
Dimensions[WxHxD] / Weight 109 x 41.5 x 327mm (4.25 x 1.69 x 13”) / 1.95 kg (4.3 lbs) |
DESIGN STANDARDS |
Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC/EN 62040-1:2008+A1:2013 UL 60950-1:2014, UL1778:2014, CSA C22.2 No. 107.3-14 |
EN 61000-6-1:2019, -6-2:2019, - 6-3:2007 + A1:2011, - 6-4:2019, IEC 61000-6-5:2015 EMC EN 62040-2:2006 (C1 emissions, C2/C3 immunity), FCC CFR 47 Part 15 EN50121 -2:2017+A1:2019, -4:2016+A1:2019, -5:2017+A1:20195) |
EU 2015/863 (RoHS) & 2012/19/EU (WEEE) / ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) Environment Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised |
1) AC load has priority. Maximum available DC output power and current is dependent on 3) If DC port is overloaded pulling the voltage below 194V the input current may increase above this level. instant AC load and AC input voltage; i.e maximum 800W/7.4A at full AC power and nominal 4) Reduced performance - no over load support, and for 200 - 240 VAC output THD will increased and maximum input for 230VAC. output power de-rates (to 970W for 230 VAC @ 180 VDC) 5) to meet surge requirement of 4kV external surge 2) DC port must still be considered bi-directional port; voltage will present if mains powered protection is needed on AC ports 6) required FW version ≥ 1.10/1.10 |
Solutions
We provide a complete solutions including site survey, propose
professional plan according to customer’s request ,technical
support, and maintenance service for Telecommunication Companies in
and out of China. We have a competent team and a network of trusted
Partners around the world.
FAQ :
1. How do you control the quality?
A:All products before the shipment are simulated usage scenarios,
load and full load and current sharing test to ensure the quality
of the product.
2. What is your minimum order quantity?
A:There is no minimum order quantity, and one can also be done. The
only difference is the price and schedule.
3. Can you introduce your company?
A:I am very honored. I will send you the company’s introduction
document later to give you a more comprehensive and direct
introduction to our company’s information.
4. What are the advantages of your company?
A:Adequate inventory, and supply guarantee for the subsequent
renewal of supply, flexible provided according to different to
different needs of customers, providing different solutions.
5. Can i send samples?Report it to me along with the price?
A:You can send samples, the samples are subject to large pride, and
the freight needs to be borne by you.
6. How do your company deal with the problem on quality?
A:Our company has been doing this industry for almost 10 years. It
has already had a certain reputation. We will carefully analyze it.
If it is indeed our quality problem, you can rest assured that it
will do things according to the contract agreement and will never
let you have any after the worries, our service team will be happy
to serve you.
7 What about the quality ?
A:100% original with new package. we will test each item before
posted to make sure each item with good quality.
8 How many months for guarantee ?
A: 1 year quality guarantee
9 How to deal with any inferior -quality goods ?
A: Goods can be post by with our charge of post fee for any bad
quality products within guarantee time.