Hepatectomy Electrode Optimized Operating Frequency for Stable Liver Tumor Removal

Brand Name:Better Health
Certification:CE,ISO
Model Number:HE-100
Minimum Order Quantity:1 Set
Delivery Time:5-8 days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Address: No. 108, Section 5, 1st Ring Road East, Anhui Province, China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Optimized Operating Frequency for Stable Liver Tumor Removal Device Surgical Procedure and Electrode Removal

Product Description:

The Hepatectomy Electrode is optimized to operate at an operating frequency of 4 MHz, generating a stable and effective plasma field for consistent tissue ablation. This ensures that the liver resection tool is successful in removing the targeted area without any damage to the surrounding tissues.

The Hepatic Resection Tool is designed to provide Effective Hemostasis during the procedure, as the plasma energy simultaneously seals the blood vessels during ablation, significantly reducing intraoperative bleeding. This not only improves the visibility of the surgical field but also minimizes the risk of blood loss-related complications.

The slim 2 mm diameter of the electrode allows for easy insertion and precise manipulation within the liver tissue, minimizing trauma during insertion. This ensures that the liver resection procedure is successful with minimal discomfort for the patient.

The Radiofrequency Liver Resection Probe is an essential tool for any surgeon performing liver resection procedures. Its efficient and effective design ensures that the procedure is completed with precision and minimal trauma to the patient.

Features:

  • Product Name: Customizable Energy Output Precision Ablation Plasma Hepatectomy Electrode
  • Surgical Procedure: A procedure that involves positioning, insertion of the electrode, radiofrequency ablation, and removal of the electrode.
  • Electrode Diameter: A slim 2 mm diameter for easy insertion and precise manipulation within the liver tissue, minimizing trauma during insertion.
  • Precision Ablation: Allows for highly accurate targeting of liver tissue, enabling surgeons to precisely remove tumors or diseased areas while sparing adjacent healthy tissue as much as possible.
  • Electrode Length: Available in 10 cm, 15 cm, and 20 cm lengths to accommodate different surgical requirements and patient anatomies.

This device is a Surgical Device for Liver Resection, also known as a Hepatic Resection Tool or a Radiofrequency Liver Resection Probe.

Technical Parameters:

Surgical ProcedurePositioning, insertion of the electrode, radiofrequency ablation, and removal of the electrode
Product CategoryHepatectomy Electrode
Product NameCustomizable Energy Output Precision Ablation Plasma Hepatectomy Electrode
Electrode DiameterA slim 2 mm diameter for easy insertion and precise manipulation within the liver tissue, minimizing trauma during insertion
Plasma Energy OutputAdjustable power levels ranging from 20 W to 80 W, allowing surgeons to customize the ablation process according to the specific characteristics of the tissue being treated
Tissue Penetration DepthUp to 5 mm per application, providing controlled and targeted ablation without over-penetration into deeper healthy tissues
Radiofrequency Ablation TechnologyA non-invasive local treatment method that uses high-frequency alternating current to generate heat to destroy the target tissues
Clinical Applications and EffectsThe application of radiofrequency ablation in hepatectomy can effectively reduce bleeding during the surgery and ensure the complete ablation of tumors in laparoscopic hepatectomy. This method is especially suitable for patients who are unable to undergo traditional open surgeries or can be used as an auxiliary treatment measure before or after the surgery
Effective HemostasisThe plasma energy simultaneously seals blood vessels during ablation, significantly reducing intraoperative bleeding. This not only improves the visibility of the surgical field but also minimizes the risk of blood loss-related complications
Electrode LengthAvailable in 10 cm, 15 cm, and 20 cm lengths to accommodate different surgical requirements and patient anatomies

This liver tumor removal device is a surgical device for liver resection that leverages radiofrequency ablation technology. The Customizable Energy Output Precision Ablation Plasma Hepatectomy Electrode has a slim 2 mm diameter for easy insertion and precise manipulation within the liver tissue, minimizing trauma during insertion. It has adjustable power levels ranging from 20 W to 80 W, allowing surgeons to customize the ablation process according to the specific characteristics of the tissue being treated. The tissue penetration depth is up to 5 mm per application, providing controlled and targeted ablation without over-penetration into deeper healthy tissues. The electrode is available in 10 cm, 15 cm, and 20 cm lengths to accommodate different surgical requirements and patient anatomies. The plasma energy simultaneously seals blood vessels during ablation, significantly reducing intraoperative bleeding. This not only improves the visibility of the surgical field but also minimizes the risk of blood loss-related complications.

Applications:

One of the key features of this electrode is its effective hemostasis. The plasma energy simultaneously seals blood vessels during ablation, significantly reducing intraoperative bleeding. This not only improves the visibility of the surgical field but also minimizes the risk of blood loss-related complications. The tissue penetration depth is up to 5 mm per application, providing controlled and targeted ablation without over-penetration into deeper healthy tissues. The adjustable power levels ranging from 20 W to 80 W allow surgeons to customize the ablation process according to the specific characteristics of the tissue being treated.

The Better Health HE-100 Hepatectomy Electrode is especially suitable for hepatocellular carcinoma resection. The application of radiofrequency ablation in hepatectomy can effectively reduce bleeding during the surgery and ensure the complete ablation of tumors in laparoscopic hepatectomy. This method is particularly helpful for patients who are unable to undergo traditional open surgeries or can be used as an auxiliary treatment measure before or after the surgery.

Overall, the Better Health HE-100 Hepatectomy Electrode is an essential surgical device for liver resection procedures. With its effective hemostasis and tissue penetration depth, it is the perfect surgical device for hepatocellular carcinoma resection. It is designed to provide surgeons with the precision and control necessary to ensure a successful surgery with minimal complications.

Support and Services:

The Hepatectomy Electrode product is a medical device used in surgical procedures to remove liver tissue. Our technical support team is available to assist with any questions or issues related to the use of the product. We also offer training and educational resources to ensure proper use and handling of the Hepatectomy Electrode. In addition, our services include maintenance and repair of the product, as well as replacement parts and accessories. Please contact us for further information.

Packing and Shipping:

Product Packaging:

  • One Hepatectomy Electrode
  • Instruction Manual
  • Protective Cover

Shipping:

  • Product will be shipped within 2 business days of order confirmation.
  • Shipping is free within the United States.
  • International shipping rates apply.

FAQ:

Q: What is the brand name of the Hepatectomy Electrode product?

A: The brand name of the Hepatectomy Electrode product is Better Health.

Q: What is the model number of the Hepatectomy Electrode product?

A: The model number of the Hepatectomy Electrode product is HE-100.

Q: What certifications does the Hepatectomy Electrode product have?

A: The Hepatectomy Electrode product has CE and ISO certifications.

Q: Where is the Hepatectomy Electrode product made?

A: The Hepatectomy Electrode product is made in China.

Q: What is the minimum order quantity for the Hepatectomy Electrode product?

A: The minimum order quantity for the Hepatectomy Electrode product is 1 set.

Q: What is the price of the Hepatectomy Electrode product?

A: The price of the Hepatectomy Electrode product is negotiable.

Q: What are the payment terms for the Hepatectomy Electrode product?

A: The payment terms for the Hepatectomy Electrode product are L/C, T/T, and Western Union.

Q: What is the supply ability of the Hepatectomy Electrode product?

A: The supply ability of the Hepatectomy Electrode product is 10000 sets per year.

Q: What is the delivery time for the Hepatectomy Electrode product?

A: The delivery time for the Hepatectomy Electrode product is 5-8 days.

Q: How is the Hepatectomy Electrode product packaged?

A: The Hepatectomy Electrode product is packaged in a paper carton.

China Hepatectomy Electrode Optimized Operating Frequency for Stable Liver Tumor Removal supplier

Hepatectomy Electrode Optimized Operating Frequency for Stable Liver Tumor Removal

Inquiry Cart 0