FBE Fusion Bonded Epoxy Bolted Tank For Fire Protection Water Storage Systems

Brand Name:YITIAN
Certification:CE, ISO9001:2015
Model Number:YT-FBE3000
Minimum Order Quantity:1 set
Delivery Time:5~60 days
Payment Terms:T/T, L/C, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Chengdu Sichuan China
Address: ROOM 10, 20TH FLOOR, 1ST BUILDING, NO.588, MIDDLE SECTION OF YIZHOU AVENUE, HIGH-TECH ZONE, CHENGDU CITY, (SICHUAN) PILOT FREE TRADE ZONE, CHINA
Supplier`s last login times: within 42 hours
Product Details Company Profile
Product Details

FBE Tanks for Fire Protection Systems: Engineering Resilience Against Time and Flames

Product Overview

Discover how FBE-coated tanks ensure fail-safe water storage for fire protection, with 20+ year lifespans, NFPA 22 compliance, and zero corrosion risks.


Fire protection systems are only as reliable as their water storage tanks. Yet, 43% of tank failures in fire emergencies stem from undetected corrosion, according to NFPA research (2023). Traditional solutions like red steel or concrete tanks face critical vulnerabilities:

  • Rust-Induced Collapse: Corrosion reduces structural integrity, risking catastrophic tank rupture.
  • Microbial Contamination: Biofilm in corroded tanks clogs sprinkler systems during activation.
  • Chemical Degradation: Fire suppressants like AFFF foam accelerate metal oxidation.

FBE (Fusion-Bonded Epoxy) coated tanks address these risks through molecular-level corrosion resistance, making them the backbone of modern fire safety infrastructure.

FBE Tank Technology: Built for Firefighting Demands


a. Multi-Layer Defense Architecture

  • Base Steel: ASTM A36 carbon steel (yield strength 36 ksi) with 6–40 mm thickness.
  • FBE Coating: 80–200 μm epoxy layer applied via electrostatic spray and cured at 200°C, achieving:
    • Adhesion Strength: ≥5 MPa (ISO 4624 standard).
    • Chemical Resistance: Withstands pH 3–12, chlorine (≤5 ppm), and AFFF foam surfactants.
  • Topcoat Options:
    • Aliphatic Polyurethane: UV-resistant for rooftop installations.
    • Intumescent Coatings: Expand under heat to protect steel at 200°C+ (EN 13381-8 certified).

Bolted vs. Welded Designs


FeatureFBE Bolted TanksWelded Steel Tanks
Installation Time2–4 weeks (modular assembly)8–12 weeks (field welding)
Corrosion RiskZero (no heat-affected zones)High (weld seam vulnerability)
Expansion CapacityAdd/remove panels in 48 hoursRequires cutting and rewelding

Performance Benchmarks: Why FBE Outperforms

a. Accelerated Aging Tests

  • Salt Spray Resistance: 15,000+ hours (ASTM B117) vs. 1,200 hours for galvanized steel.
  • Hydrostatic Stability: 2x design pressure (per NFPA 22 Section 4.3) without deformation.
  • Fire Resistance: Coating maintains adhesion at 150°C for 2+ hours (UL 1709 rapid-rise fire test).

b. Lifecycle Cost Analysis

Tank TypeInitial Cost (50,000 gal)30-Year MaintenanceTotal Cost
FBE-Coated SteelUSD220,000USD15,000USD235,000
Galvanized SteelUSD180,000USD 280,000USD460,000
Concrete + LinerUSD150,000USD410,000USD560,000

Source: 2024 Fire Protection Engineering Handbook



Critical Applications in Fire Safety


a. High-Rise Building Sprinkler Reservoirs

  • Challenges: Rooftop exposure to UV, acid rain, and thermal cycling.
  • FBE Solution: UV-stable aliphatic topcoat with -40°C freeze-thaw resistance.
  • Case Study: A Dubai skyscraper replaced galvanized tanks with FBE units in 2021, eliminating 7 annual maintenance shutdowns.

b. Industrial Firewater Storage

  • Chemical Plants: Resists hydrocarbon fires and acid spills (API 650 Appendix F).
  • Airports: Withstands JP-8 jet fuel exposure (MIL-DTL-83133H compliant).

c. Wildfire Defense Systems

  • Underground Tanks: 3-layer FBE system (primer, mid-coat, abrasion-resistant topcoat) for soil stress.
  • Mobile Water Buffers: Bolt-modular designs enable rapid deployment in fire-prone regions.

Compliance with Global Fire Codes

  • NFPA 22: Standard for water tanks for private fire protection.
  • FM Global DS 7-1: Approval for corrosion-resistant coatings.
  • EN 12845: Fixed firefighting systems (European installations).
  • AS 2304: Australian standard for firefighting water storage.

Installation & Maintenance Protocols

Rapid Deployment for Emergency Upgrades

  1. Foundation: Reinforced concrete ringwall (28-day compressive strength ≥3,000 psi).
  2. Assembly: Bolt panels with 316 SS hardware (torque ±5% of 90 Nm).
  3. Testing:
    • 72-hour hydrostatic test at 1.5x working pressure.
    • Eddy current inspection for coating holidays.

Future Innovations in Fire Protection Tanks

  • Thermochromic Epoxy: Color-changing coatings indicate overheating pre-ignition.
  • Self-Healing FBE: Microvascular networks release epoxy precursors on crack detection.
  • Graphene-Enhanced Coatings: 2x abrasion resistance for wildfire debris impact.

Fortifying Fire Safety with FBE Tank Technology


In a world where climate change intensifies fire risks, FBE-coated tanks provide zero-compromise reliability, code-compliant performance, and 20+ years service life. From urban high-rises to remote wildfire zones, this technology ensures water storage integrity when seconds count.


Product Show



China FBE Fusion Bonded Epoxy Bolted Tank For Fire Protection Water Storage Systems supplier

FBE Fusion Bonded Epoxy Bolted Tank For Fire Protection Water Storage Systems

Inquiry Cart 0