Add to Cart
Grundfos ALPHA2 high-efficiency circulator pumps are designed for
circulating liquids in heating systems. The stainless-steel variant
of the ALPHA2 is suitable for e.g. domestic hot-water systems. With
an energy efficiency index (EEI) well below the ErP benchmark, it
ensures substantial energy savings. Flow range : <3m³/h Lift range : ≤6m Maximum working pressure : 10bar liquid temperature : -25 .. 110 °C Aplication field : Is a household hot water system circulation pump equipped with a stainless steel pump casing. AUTOADAPT will enable the water pump to continuously adapt to the system, achieving optimal adaptability and low energy consumption. |
The AUTOADAPT function continuously adapts the pump performance to
the actual heat demand, i.e. the size of the system and changing
heat demand during the year. The AUTOADAPT feature finds the
setting that provides optimal comfort with minimal energy
consumption and makes the commissioning fast, safe, and easy.
ALPHA2 also offers proportional-pressure, constant-pressure and
constant-curve control modes.
The Grundfos ALPHA2 is designed to drive the circulation of media
in heating systems. Stainless steel pump heads can also be used for
household hot water systems.
Grundfos ALPHA2 is suitable for the following systems:
1.The system needs to match actual needs by changing the operating
point of the water pump
2.System of flow and temperature changes
3.A system that requires nighttime deceleration
Pump liquid
This pump is suitable for the following media:
1.Clean, thin, non corrosive, non explosive liquid, free of solid
particles or fibers.
2.Cooling liquid without mineral oil.
3.Domestic hot water (tap water), with a hardness not exceeding 14
° dH, a temperature not exceeding 65 ° C, and a short-term peak
value not exceeding 70 ° C. The dissolved calcium in tap water
should not form scale.
4.Water softening.
Automatic nighttime deceleration
The Grundfos ALPHA2 can choose to activate the automatic
deceleration function at night.
The automatic deceleration at night can be activated through the
buttons on the panel.
Factory settings: not enabled.
Note: If the pump is set to constant speed I, II, or III, the night
time automatic deceleration function cannot be used.
When the night automatic deceleration function is activated, the
pump will automatically switch between night deceleration mode and
normal working mode. The switching depends on the pipeline
temperature measured by the built-in temperature sensor.
function
When enabling the automatic deceleration function at night in the
system, the pump must be installed on the pipeline.
The switching between normal operation and nighttime deceleration
mode is determined by the temperature of the pipeline.
When the pipeline temperature exceeds 10 ° C to 15 ° C for about 2
hours, the pump will automatically switch to the night time
automatic deceleration mode. The rate of temperature decrease must
be at least 0 1 ° C.
When the pipeline temperature rises by about 10 ° C, the pump
switches back to normal operating mode, which does not depend on
time.
install
In the vast majority of installation scenarios, the Grundfos ALPHA2
only requires mechanical installation and then power on. When installing the water pump, the motor shaft must be kept horizontal. |