For more questions about how to choose a particle air filter, how to maintain the Air Compressor Filter, how long the Coalescing Air Filter should be maintained, and how the compressor air filter works, please contact us by email or phone.
Installation method of Compressed Air Filter
1. Clean the compressed air pipes and valves connected to the air inlet and outlet of the filter before installation.
2. Adopt the combination of main pipe filtration and terminal filtration to ensure the gas quality at the point of use.
3. When installing, the air inlet and outlet of the filter should be kept level, and the sewage outlet should be at the bottom. A certain space must be reserved in the vertical direction to facilitate the maintenance of the filter and the replacement of the Filter Element.
4. The filter of the screw air compressor should be installed in a ventilated and cool place, as close as possible to the air point, to reduce the influence of the pipeline on the quality of the filtered compressed air.
5. Install and use within the specified working pressure and working temperature range, and install all levels of filters in the correct order according to the air inlet and outlet instructions or the direction indicated by the arrow, from coarse to fine installation. Avoid bypass as much as possible during installation. Because the oil in the air is bypassed to the downstream of the filter and then sticks to the inner wall of the pipeline, it is difficult to find effective means to remove it.
6. The filter element should be replaced regularly. Carefully record the replacement time. It is recommended that the working time zone should not exceed 6000 hours.
7. The discharge time of the auto drain is suitable for draining the liquid water, and the discharge interval is subject to the water content in the pipeline;
8. Different grades of compressed Air Filters can be equipped with zero pressure loss floating ball drain valves or manual valves according to customer requirements.
Technical Specification
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m³/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C(clearance for housing) | ||
DT009 | RC1/4" | 5.0 | 0.3 | 10.6 | 80.6 | 69.0 | 224.1 | 24.6 | 173.9 | 50.5 |
DT010 | RC3/8" | 10.0 | 0.6 | 21.2 | 80.6 | 69.0 | 224.1 | 24.6 | 173.9 | 50.5 |
DT011 | RC1/2" | 20.0 | 1.2 | 42.4 | 108.2 | 93.3 | 275.3 | 30.1 | 220.6 | 53.3 |
DT012 | RC3/4" | 25.1 | 1.5 | 53.0 | 108.2 | 93.3 | 275.3 | 30.1 | 220.6 | 53.3 |
DT013 | RC1/2" | 30.1 | 1.8 | 63.5 | 108.2 | 93.3 | 315.3 | 30.1 | 260.6 | 53.3 |
DT014 | RC3/4" | 33.4 | 2.0 | 70.6 | 108.2 | 93.3 | 315.3 | 30.1 | 260.6 | 53.3 |
DT015 | RC3/4" | 46.8 | 2.8 | 98.8 | 133.0 | 113.9 | 399.6 | 40.7 | 291.0 | 59.6 |
DT016 | RC1" | 60.1 | 3.6 | 127.1 | 133.0 | 113.9 | 399.6 | 40.7 | 291.0 | 59.6 |
DT017 | RC1" | 80.2 | 4.8 | 169.4 | 133.0 | 113.9 | 468.4 | 40.7 | 359.8 | 59.6 |
DT018 | RC1-1/2" | 100.2 | 6.0 | 211.8 | 133.0 | 113.9 | 468.4 | 40.7 | 359.8 | 59.6 |
DT019 | RC1-1/2" | 125.3 | 7.5 | 264.8 | 133.0 | 113.9 | 533.7 | 40.7 | 425.3 | 59.6 |
DT020 | RC2" | 200.0 | 12.0 | 424.0 | 170.0 | 158.3 | 783.1 | 52.9 | 623.0 | 59.6 |
DT021 | RC2" | 266.7 | 16.0 | 565.3 | 170.0 | 158.3 | 1065.4 | 52.9 | 945.3 | 59.6 |
DT022 | RC2-1/2" | 316.7 | 19.0 | 671.3 | 170.0 | 158.3 | 1065.4 | 52.9 | 945.3 | 59.6 |
Technical requirements | Maximum operating pressure: 10 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
Replacement and Spare Parts