Air Compressor Intake Filter Element

Brand Name:Yuka
Minimum Order Quantity:10 pieces
Delivery Time:3-7working days
Payment Terms:L/C,T/T
Model No.:DT019
Brand:YUKA
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: No,8 Qinglan 1 Rd Pingshan Disctric, Shenzhen 518118, China
Supplier`s last login times: within 22 hours
Product Details Company Profile
Product Details
Product Description

Product Feature & Advantage

①Filter housing with 100% leakage-tested in three times, with 15 years spanlife. Low overall costs for owner.

②No-touch element design, easy to maintenance and repaired.

③Design as ISO8573.1-2010 standard in class 1 Level filtration performance. Protect your precise equipment and optimization your production.

④Low pressure drop, saving energy and cost.

⑤Fitted for all applications and all type of air compressor.


Element GradeFilter TypeFiltration AccuracyOil ConcentrationRemark
PFPrefilter≤ 5 μmCan be negligibleBefore air dryer
AOMedium filter≤ 1 μm≤ 1ppmAfter air dryer
AAHigh Precision filter≤ 0.01 μm≤0.01ppmBehind grade AO
ACSActivated Carbon Filter/≤0.003ppmBehind grade AA
AXUltra-high precision filter≤ 0.01 μm≤0.001ppmBehind grade ACS
ARParticulate air filter1μm-After Desiccant Air Dryer
AARParticulate Air Filter0.01μm-After grade AR

What to do if Pressure drop becomes larger?


1. If the Air Filter Element is clogged or the adsorption capacity is too large, replace the Filter Element.
2. The intake impurity load is large and pre-treatment is performed.
3. If the filter cartridge has accumulated water, find out the cause and drain the remaining accumulated water.
4. The automatic drainer fails, adjust and repair or replace the auto drainer.
5. The filter installation is not level, reinstall it.



Technical Specification


ModelPipe sizeFlow ratesDimension (mm)
L/Sm³/minscfmW (Width)D (Depth)H (Height)ABC (clearance for housing)
DT009RC1/4"5.00.310.680.669.0224.124.6173.950.5
DT010RC3/8"10.00.621.280.669.0224.124.6173.950.5
DT011RC1/2"20.01.242.4108.293.3275.330.1220.653.3
DT012RC3/4"25.11.553.0108.293.3275.330.1220.653.3
DT013RC1/2"30.11.863.5108.293.3315.330.1260.653.3
DT014RC3/4"33.42.070.6108.293.3315.330.1260.653.3
DT015RC3/4"46.82.898.8133.0113.9399.640.7291.059.6
DT016RC1"60.13.6127.1133.0113.9399.640.7291.059.6
DT017RC1"80.24.8169.4133.0113.9468.440.7359.859.6
DT018RC1-1/2"100.26.0211.8133.0113.9468.440.7359.859.6
DT019RC1-1/2"125.37.5264.8133.0113.9533.740.7425.359.6
DT020RC2"200.012.0424.0170.0158.3783.152.9623.059.6
DT021RC2"266.716.0565.3170.0158.31065.452.9945.359.6
DT022RC2-1/2"316.719.0671.3170.0158.31065.452.9945.359.6
Technical requirementsMaximum operating pressure: 10 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C
PressureBarg12345678910111213141516
Psig152944597387100116131145160174189203219232
Correction factor0.380.530.650.760.850.931.001.071.131.191.231.311.361.411.461.51

Replacement and Spare Parts


Installation Tips of Compressed Air Filter


1. Clean the compressed air pipes and valves connected to the air inlet and outlet of the filter before installation.


2. Adopt the combination of main pipe filtration and terminal filtration to ensure the gas quality at the point of use.


3. When installing, the air inlet and outlet of the filter should be kept level, and the sewage outlet should be at the bottom. A certain space must be reserved in the vertical direction to facilitate the maintenance of the filter and the replacement of the filter element.


4. The filter of the screw air compressor should be installed in a ventilated and cool place, as close as possible to the air point, to reduce the influence of the pipeline on the quality of the filtered compressed air.


5. Install and use within the specified working pressure and working temperature range, and install all levels of filters in the correct order according to the air inlet and outlet instructions or the direction indicated by the arrow, from coarse to fine installation. Avoid bypass as much as possible during installation. Because the oil in the air is bypassed to the downstream of the filter and then sticks to the inner wall of the pipeline, it is difficult to find effective means to remove it.


6. The filter element should be replaced regularly. Carefully record the replacement time. It is recommended that the working time zone should not exceed 6000 hours.


7. The discharge time of the auto drain is suitable for draining the liquid water, and the discharge interval is subject to the water content in the pipeline;


8. Different grades of compressed Air Filters can be equipped with zero pressure loss floating ball drain valves or manual valves according to customer requirements.



China Air Compressor Intake Filter Element supplier

Air Compressor Intake Filter Element

Inquiry Cart 0