Coalescer Air Filter for Air Compressor

Brand Name:Yuka
Minimum Order Quantity:50pcs
Delivery Time:3-7working days
Payment Terms:L/C,T/T
Model No.:HFD060
Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: No,8 Qinglan 1 Rd Pingshan Disctric, Shenzhen 518118, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details
Product Description

Compressed air in industrial applications contains in 1Nmᶟ more than 100 million of polluting articles. Most of these particles are so small in dimension, less than 5 micron, that they cannot be intercepted by the standard intake filters installed in the compressors. Such particles, mixed with water and oil vapour generated during compression, cause the early wear and tear of the appliances and consequently they are the cause of expensive interruptions of the production and remarkable increase maintain.


Selection right Air Filters will allow the best choice of the suitable equipment according to the quantity of air to be treated and the necessary filtration degree in order to increase and improve the performances of the whole system.


HFD series with 7 Grades Filter Element: PF/AO/AA/AX/ACS/AR/AAR


PFAOAAAXACSARAAR
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligibleHigh efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21℃),1ppm(w).High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21),0.01ppm(w)Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21),0.001ppm(w)Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21),0.003ppm(w)Dust particles whose diameter more than 1μm can be removedDust particles whose diameter more than 0.01μm can be removed

Product Specification

Model)Pipe sizeFlow ratesDimension (mm)
L/Sm³/minscfmW (Width)D (Depth)H (Height)AB
HFD010RC1/2"16.71.035.3908225537179
HFD020RC3/4"25.01.553.0908225537179
HFD030RC3/4"30.01.863.6908228637212
HFD040RC1"33.32.070.6908228637212
HFD050RC3/4"46.72.898.912011335953269
HFD060RC1"60.03.6127.112011335953269
HFD070RC1"80.04.8169.512011345953369
HFD080RC1-1/2"120.07.2254.212011345953369
Technical requirementsMaximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C

PressureBarg12345678910111213141516
Psig152944597387100116131145160174189203219232
Correction factor0.380.530.650.760.850.931.001.071.131.191.231.311.361.411.461.51


How to install Compressed Air Filter?


1. Clean the compressed air pipes and valves connected to the air inlet and outlet of the filter before installation.


2. Adopt the combination of main pipe filtration and terminal filtration to ensure the gas quality at the point of use.


3. When installing, the air inlet and outlet of the filter should be kept level, and the sewage outlet should be at the bottom. A certain space must be reserved in the vertical direction to facilitate the maintenance of the filter and the replacement of the filter element.


4. The filter of the screw air compressor should be installed in a ventilated and cool place, as close as possible to the air point, to reduce the influence of the pipeline on the quality of the filtered compressed air.


5. Install and use within the specified working pressure and working temperature range, and install all levels of filters in the correct order according to the air inlet and outlet instructions or the direction indicated by the arrow, from coarse to fine installation. Avoid bypass as much as possible during installation. Because the oil in the air is bypassed to the downstream of the filter and then sticks to the inner wall of the pipeline, it is difficult to find effective means to remove it.


6. The filter element should be replaced regularly. Carefully record the replacement time. It is recommended that the working time zone should not exceed 6000 hours.


7. The discharge time of the auto drain is suitable for draining the liquid water, and the discharge interval is subject to the water content in the pipeline;


8. Different grades of compressed air filters can be equipped with zero pressure loss floating ball drain valves or manual valves according to customer requirements.


Feature & Benefit

Operating pressure: 1.6Mpa

Flow rate: 1.0 to 7.2m³/min (till now)

Filtration Rate: 5μm/1μm/0.1μm/0.01μm

Material: Aluminum alloy

Unique lock design,to ensure easy for maintenance and air tightness.

Parallel and wall connection kit available.


Sources of compressed air pollutants

1. Atmosphere

Air compressors suck in and compress a large amount of atmosphere. They continue to fill the system while bringing in extremely small pollutants. These pollutants include: water vapor, atmospheric dirt, dust and pollen particles, oil vapor, and microorganisms.


2. Air compressor

In addition to the pollutants inhaled from the atmosphere, the air compressor will also mix a small amount of oil into the compressed air flow during the air compression process. This oil may exist in the form of liquid oil, aerosols and oil vapor. It is also worth noting that although so-called oil-free compressors do not directly inject oil into the airflow, they still compress the same contaminated air like an air compressor, so any oil vapor in the surrounding environment will still be affected. It is compressed and enters the downstream system. After the compression stage, the aftercooler cools the air, which can condense any water vapor and mix it into the compressed air stream in the form of liquid water or aerosol.


High Efficiency Removal of Pollutant
Our Medium & high pressure filter features efficiency fiber glass and felt media to maximize the filtration of dry and wet dust, particulates, oil suspended solids and water droplets. Minimize pressured drop and maintain economical operation costs.

Superior Air Tightness
Unique lock design,easy to replace and maintenance

Avoid Second Pollution
Inside and outside with anti-corrosion, with stainless steel manual ball valve.

Low Differential Pressure
The optimized flow design and the use of filter materials serve to keep differential pressure at a constant low level during the entire service life of the element without compromising it's dirt holding capacity.

High-tech design
It is clearly visible due to the edges at the filter head of the compressed air inlet to ensure reliable connection between the left and right filter housings and the left and right filter housing parts during the assembly process.
Compressed air provides a smooth, non-turbulent air velocity when entering the filter element.


China Coalescer Air Filter for Air Compressor supplier

Coalescer Air Filter for Air Compressor

Inquiry Cart 0