Product Details


Power Transformer Degaussing Instrument

With DC Frequency Conversion Attenuation Principle


Product Description


The power transformer transformer degaussing instrument is a special equipment for eliminating the hazards of residual magnetism after the DC resistance test of large power transformer transformers. It plays an extremely important role in protecting power transformer transformers from the impact of excitation inrush current and ensuring safe operation.


Due to the inherent hysteresis phenomenon of ferromagnetic materials, residual magnetism will remain in the iron core after performing operations such as voltage ratio and DC resistance measurements on the power transformer. Due to the existence of residual magnetism, when the transformer is put into operation, the residual magnetism of the iron core will saturate the transformer core for half a cycle, generating a large number of harmonics in the excitation current. This not only increases the reactive power consumption of the transformer, but may also cause the relay protector to malfunction. , causing certain economic losses. Therefore, we must perform degaussing work before the transformer is put into operation to ensure the safe and normal operation of the transformer.


This power transformer transformer degaussing instrument XHXC105 adds an automatic degaussing mode based on the original series of products, so users do not have to repeat operations. The size of the LCD module is increased to display richer information. Two-button operation: red for selection and reset, green for confirmation and start, making operation more convenient. The degaussing time of the product has been increased from the original 30 minutes to less than 4 minutes.


Detailed Photos


Product Parameters

Degaussing current5A, 1A, 200mA, 5mA can be customized
Degaussing methodmanual, automatic
Degaussing timemanual 3min/time, automatic 9min/time
Degaussing effectgreater than 90%/time
Degaussing progress0~100%
Working power supplyAC 220V±10%
Power frequency50Hz±1Hz
Ambient temperature-25ºC~50ºC
Ambient humidity≤90%
Weight5kg (excluding test line)


Features
1, Adopts patented technology-DC frequency conversion attenuation principle;
2, The three-phase transformer can achieve the purpose of degaussing only by degaussing the B phase;
3, With automatic flow stabilization judgment and 16-bit AD data acquisition and processing functions;
4, With manual/automatic degaussing mode;
5,Fast degaussing speed - single time increased from 30min to no more than 4min;
6,The degaussing effect is obvious - increased from 80% to more than 90% in a single pass;
7,The current line for DC resistance testing can be directly used to facilitate matching with DC resistance testing;
8,Using Chinese interface, the interface is clear and the degaussing progress is displayed in real time;
9,Suitable for eliminating residual magnetism before large-scale power transformers and transformers of 35kV and above are put into operation; especially for large-capacity transformers with voltage levels of 330kV and above;
This product is small in size and light in weight, making it very suitable for use on site
.




Degaussing output: connected to the degaussed transformer or transformer bushing


LCD screen: displays degaussing working mode, current value, and degaussing progress


Power switch: AC 220V power switch


Reset (red button): mode and current selection/degaussing to end discharge/interrupt instrument operation


Start (green button): menu confirmation/degaussing start


Ground terminal: connected to the ground wire


AC 220V: Connect to AC 220V power socket.



Main performance features


1. Adopt patented technology-DC frequency conversion attenuation principle;


2. The three-phase transformer can achieve the purpose of degaussing only by degaussing the B phase;


3. It has automatic flow stabilization judgment and 16-bit AD data acquisition and processing functions;


4. With manual/automatic degaussing mode;


5. The degaussing speed is fast - a single time is increased from 30 minutes to no more than 4 minutes;


6. The degaussing effect is obvious - increased from 80% to more than 90% in a single pass;


7. The current line for DC resistance testing can be directly used to facilitate matching with DC resistance testing;


8. The English interface is adopted, the interface is clear, and the degaussing progress is displayed in real time;


9. Suitable for eliminating residual magnetism before large power transformers and transformers of 35kV and above are put into operation; especially for large-capacity transformers with voltage levels of 330kV and above;


10. This product is small in size and light in weight, making it very suitable for use on site.


Packaging & Shipping

By wooden case filled with foam




English version is available.



Company profile


XZH TEST is a professional cable fault detection equipment manufacturer. We are a young team. Our development philosophy is humanized management, intelligent cloud-based products, and internationalized operations. Our development mission is to make electrical equipment free from undetectable failures.


Since its inception in 2013, our company has grown to become one of the largest manufacturer of underground cable fault detection equipment in China. An ISO 9001 and CE certified company, we produces a broad range of testing equipment.


What we can do


We have the ability to innovate new products and technologies.


We can provide complete system solutions for your project.


We provide online and offline practical and theoretical training.


We provide instrument repair and calibration.




FAQ


1. Are you a trading company or a manufacturer?

We are a professional manufacturer with more than 10 years of experience. We can strictly control the quality of parts and finished products.


2. What is the delivery time and inventory?

If our best-selling products are in stock, it will be 5-8 working days for shipment. But for mass production and customized production, the time will take 2-4 weeks.


3. What are your payment terms?

Payment ≤ USD 2000, 100% T/T prepayment. Orders over USD 2000 can be negotiated.


4. How long is your product warranty?

We provide 1 year warranty for the equipment.


5. How do you ensure quality?

The product links include R&D, manufacturing, commissioning and technical support, following strict and scientific management principles. Therefore, we can support strong production and R&D capabilities, and can produce high-quality products at competitive prices to meet customers' high requirements.


6. What support can I get?

We will provide training support, marketing support, technical support and supply chain support. You can contact us for more information.


7. Where is your factory? Can I visit your factory?

We are located in Xi'an, Shaanxi, China. We are close to Xi'an Xianyang International Airport, which is about 2 and half hours by plane from Shanghai and Guangzhou. All customers from all over the world are welcome to visit us.


8. How to become your dealer?

Every company interested in power system instruments can contact us without hesitation, including website letters, emails, telephones, etc. We will contact you quickly according to your company information and cooperation intentions.


China Portable Fast 5A Automatic Power Transformer Degaussing demagnetization Instrument supplier

Portable Fast 5A Automatic Power Transformer Degaussing demagnetization Instrument

Inquiry Cart 0