Add to Cart
Corrtest 1A 10V multichannel potentiostat CS310X 4-channel 4 eis is a versatile instrument offering 8 slots. Multichannel potentiostat/ galvanostat model CS310X (Option B) is the 4-channel potentiostat. Four slots are occupied with potentiostat boards. The rest four idle slots are available for future adding potentiostat board(s). 1A 10V multichannel potentiostat CS310X 4-channel 4 eis equals that you have four sets independent potentiostat/galvanostat in one potentiostat. EIS module (10μHz~1MHz) is equipped in all four channels. Each channel potential control range is ±10V, current control range ±1A, can meet experiment requirement for most people. Full floating module and electrical isolation design guarantee each channel is totally independent, which ensures accurate data and efficient simultaneous measurements. You can use one computer to control the 4 channels, you can also allocate and control the channels by multiple computers.
Advantages of multichannel potentiostat CS310X 4-channel 4 eis
High current/voltage: Applied potential range ±10V, current ±1A. It can meet the needs of most studies.Comprehensive techniques: Built-in EIS (10μHz~1MHz) is equipped in all 4 channels. There are comprehensive techniques in each channel.
Warranty: 5 years warranty. We're the manufacturer, and our engineers will provide technical support anytime you need.Low cost: The price of multichannel potentiostat CS310X 4-channel 4 eis includes instrument host, software (experiment control & data processing), necessary cables, dummy cell. No other charges.
Application of multichannel potentiostat CS310X 4-channel 4 eis
● Study of Energy materials (Li-ion battery, solar cell, fuel cell,
supercapacitors), advanced functional materials
● Electrocatalysis (HER, OER, ORR, CO2RR, NRR)
● Corrosion study and corrosion resistance evaluation of metals;
quick evaluation of corrosion inhibitors, coatings, and cathodic
protection efficiency
● Electrosynthesis, electroplating/electrodeposition, anode
oxidation, electrolysis
Specifications of 1A 10V multichannel potentiostat CS310X 4-channel 4 eis
Specifications | |
Number of channels with boards: 4 | Channel insulation resistance: >100MΩ |
Communication: Ethernet | Lower-pass filter: covering 8-decade |
Potential control range: ±10V | Constant current control range: ±1A |
Potential accuracy: 0.1%×full range±1mV | Current accuracy: 0.1%×full range |
Potential resolution:10μV(>100Hz), 3μV(<10Hz) | Current resolution: 1pA |
Potential rise time: <1μs(<10mA), <10μs(<2A) | Current range: 2nA ~1A, 10 ranges |
Reference electrode input impedance: 1012Ω||20pF | Maximum current output: 1A |
Compliance voltage: ±21V | Current increment during scan: 1mA @1A/ms |
CV and LSV scan rate: 0.001mV~10000V/s | Potential increment during scan: 0.076mV@1V/ms |
CA and CC pulse width: 0.0001~65000s | DPV and NPV pulse width: 0.0001~1000s |
SWV frequency:0.001~100KHz | CV minimum potential increment: 0.075mV |
AD data acquisition:16bit@1MHz,20bit @1kHz | IMP frequency:10μHz~1MHz |
DA resolution:16bit, setup time:1μs | Current and potential range: automatic |
Operating System requirements: Windows 10 /11 | Weight: 12.5 Kg Dimensions: 40*40*14cm |
Electrochemical Impedance Spectroscopy (EIS) | |
Signal generator | |
Frequency range: 10μHz~1MHz | AC signal amplitude: 1mV~2500mV |
Frequency accuracy: 0.005% | Signal resolution: 0.1mV RMS |
DDS output impedance: 50Ω | DC Bias: -10V~+10V |
Wave distortion: <1% | Waveform: sine wave, triangular wave, square wave |
Scan mode: Logarithmic/linear, increase/decrease | |
Signal analyzer | |
Maximum integral time:106 cycles or 105s | Measurement delay:0~105s |
Minimum integral time:10ms or the longest time of a cycle | |
DC offset compensation | |
Potential compensation range: -10V~+10V | Current compensation range: -1A~+1A |
Bandwidth adjustment: automatic and manual, 8-decade frequency range |
Techniques -1A 10V multichannel potentiostat CS310X 4-channel 4 eis
Stable polarization | Open Circuit Potential (OCP) |
Potentiostatic (i-t curve) | |
Galvanostatic(E-t curve) | |
Potentiodynamic(Tafel) | |
Galvanodynamic | |
Transient polarization | Multi-Potential Steps |
Multi-Current Steps | |
Potential Stair-Step (VSTEP) | |
Galvanic Stair-Step (ISTEP) | |
Chrono methods | Chronopotentiometry (CP) |
Chronoamperometry (CA) | |
Chronocoulometry (CC) | |
Voltammetry | Cyclic Voltammetry (CV) |
Linear Sweep Voltammetry (LSV)(I-V curve) | |
Staircase Voltammetry (SCV) # | |
Square wave voltammetry (SWV) # | |
Differential Pulse Voltammetry (DPV)# | |
Normal Pulse Voltammetry (NPV)# | |
Differential Normal Pulse Voltammetry (DNPV)# | |
AC voltammetry (ACV) # | |
2nd Harmonic A.C.Voltammetry (SHACV) | |
Amperometry | Differential Pulse Amperometry (DPA) |
Double Differential Pulse Amperometry (DDPA) | |
Triple Pulse Amperometry (TPA) | |
Integrated Pulse Amperometric Detection (IPAD) | |
EIS /Impedance | Potentiostatic EIS (Nyquist, Bode) |
Galvanostatic EIS | |
Potentiostatic EIS (Optional freq.) | |
Galvanostatic EIS(Optional freq.) | |
Mott-Schottky | |
Potentiostatic EIS vs. Time (Single freq.) | |
Galvanostatic EIS vs. Time (Single freq.) | |
Corrosion measurement | Cyclic polarization curve (CPP) |
potentiodynamic(Tafel ) | |
Linear polarization curve (LPR) | |
Electrochemical Potentiokinetic Reactivation | |
Electrochemical Noise (ECN) | |
Zero resistance Ammeter (ZRA) | |
Battery test | Battery charge and discharge |
Galvanostatic charge and discharge (GCD) | |
Potentiostatic Charging and Discharging(PCD) | |
Potentiostatic Intermittent Titration Technique(PITT) | |
Galvanostatic Intermittent Titration Technique(GITT) |
Q: What’s the standard supply for multichannel potentiostat CS310X 4-channel 4 eis
A: Standard supply for multichannel potentiostat CS310X 4-channel 4 eis:
Instrument host CS310X-1set
CS studio testing & analysis software-1set
Power cable - 1 piece,
Ethernet cable - 1 piece
Cell cable –8 pcs,
Dummy cell –4
Manual
A: Yes. We will deliver the 4 pcs potentiostat/galvanostat boards to you,and you can insert the 4 potentiostat boards into the rest 4 slots and it’s very simple. We will also give you video on how to do it.
A: Yes. We can send the software package for your installation, and then please follow the steps to use the demo mode without connecting a Corrtest multichannel potentiostat CS310X.You can see the layout of the software.
A: You can use the dummy cell(we provide it along with the potentiostat) to judge whether the potentiostat works normally. The dummy cell is a simulation standard cell. You can do the potentiostatic, galavanostatic experiment and check the value of the potential and current. They should obey the Ohm law.