S-F120H fiber optic gyro is a high-precision single-axis closed-loop fiber optic gyro, as shownin Figurel , the structure of the optical system and the circuit system in one package, stable andreliable performance, easy and convenient to install, the user only needs to provide power supplythrough a plug to receive the output data of the gyro can be used. This product can be used in aviation.aerospace,marine,automotive electronics and other fields.
Figure 1 S -F120H fiber optic gyroscope model
1 Performance indicators
The performance indicators of the Table .
Table 1 Performance index of S -F120H fiber optic gyroscope
NO | parameter | unit | 1 20 HA | 1 20 HB | 1 20 HC |
Measuring range | °/s | -400~+400 | -400~+400 | -400~+400 | |
Bias stability (1 s, 100s) | °/h | ≤0.001 | ≤0.002 | ≤0.003 | |
Zero bias repeatability (1 s) | °/h | ≤0.001 | ≤0.002 | ≤0.003 | |
Scale factor asymmetry | ppm | ≤10 | ≤20 | ≤20 | |
Scale factor repeatability | ppm | ≤10 | ≤20 | ≤20 | |
Scale factor nonlinearity | ppm | ≤10 | ≤20 | ≤20 | |
Full temperature scale factor change | ppm | ≤30 | ≤50 | ≤50 | |
Random walk coefficient | °/h 1/2 | ≤0.0002 | ≤0.0003 | ≤0.0004 | |
Steady-state power consumption | W | ≤4.0 | ≤4.0 | ≤4.0 | |
bandwidth | Hz | ³200 | ³200 | ³200 | |
weight | g | ≤900 | ≤900 | ≤900 | |
Operating temperature | ℃ | -45~+70 | -45~+70 | -45~+70 | |
Storage temperature | ℃ | -50~+75 | -50~+75 | -50~+75 |
2 Product size
The appearance and installation dimensions of Figure the S -F120H fiber optic gyroscope are shown in Figure 2.
Figure 2 Appearance and installation dimensions of S -F120H fiber optic gyroscope
the S -F120H fiber optic gyroscope power supply are shown in Table Table 1.
Table 1Power supply requirements for fiber optic gyroscope
parameter | Technical requirements | Remark |
Supply current(A) | +5V: Current ≥ 0.5A | Inrush current ≥1A |
-5V: Current ≥ 0.2A | ||
Supply voltage (V) | ±5(±5%) | |
Power ripple (mv) | ≤20 | Vpp |
The gyro is connected to the external electrical system using a J30-21ZK connector. The wiring definition is shown in
Table 2:
Table 2Gyroscope external electrical connection table (J30-21ZK)
Gyro output mode | Model 422 | |
Power supply socket ( J30-21ZK) | Connection table between mainboard and acquisition line | |
8, 10 (required) | +5V | |
6, 7 (required) | DGND(AGND) | |
13, 14 (required) | -5V | |
16 (422 interface is valid) | 422 communication signal T+ | |
19 (422 interface is valid) | 422 Communication signal T- | |
15 (422 interface is valid) | 422 communication signal R+ | |
18 (422 interface is valid) | 422 Communication signal R- |
RS-422 method
High | Low | |||||||
1 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
2 | 0 | D6 | D5 | D4 | D3 | D2 | D1 | D0 |
3 | 0 | D13 | D12 | D11 | D10 | D9 | D8 | D7 |
4 | 0 | D20 | D19 | D18 | D17 | D16 | D15 | D14 |
5 | 0 | D27 | D26 | D25 | D24 | D23 | D22 | D21 |
6 | 0 | 0 | 0 | 0 | D31 | D30 | D29 | D28 |
7 | 0 | X | X | X | X | X | X | X |
8 | 0 | T6 | T5 | T4 | T3 | T2 | T1 | T0 |
9 | 0 | T13 | T12 | T11 | T10 | T9 | T8 | T7 |
10 | 0 | T20 | T19 | T18 | T17 | T16 | T15 | T14 |