OEM LEMO Wire Connector Harness Cable Assembly For Air Signals Connecting

Brand Name:BEXKOM
Certification:UL/CE/ROHS/REACH/ISO9001/ISO13485/MSDS/COC
Model Number:BK-Cab-XXX
Minimum Order Quantity:5pcs
Delivery Time:7 ~15 days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: F518,Building F, Huafeng International Robot Industrial Park, Hangcheng Road, Xixiang Street, Baoan District, Shenzhen City, 518126, China
Supplier`s last login times: within 37 hours
Product Details Company Profile
Product Details

Key Components and Materials

  1. Air and Signal Cables:

    • Air Tubing:
      • Material: Use medical-grade silicone or TPU tubing for the air channels. These materials are flexible, biocompatible, and can withstand sterilization processes.
      • Pressure Rating: Ensure the tubing can handle the air pressure requirements of dental tools without kinking or bursting.
    • Signal Wires:
      • Conductor Material: Use copper or silver-plated copper for the signal wires to ensure high conductivity and signal integrity.
      • Insulation: Select an insulation material compatible with medical standards, such as FEP (Fluorinated Ethylene Propylene) or PTFE (Polytetrafluoroethylene), which are also resistant to sterilization processes.
  2. Metal Push-Pull Connectors:

    • Compatibility: The connectors should be compatible with LEMO designs, offering secure connections with quick mating and demating capabilities.
    • Material: Use high-quality stainless steel or anodized aluminum for the connectors to ensure durability and corrosion resistance.
    • Contact Configuration: Design the connector with the appropriate number of contacts for both air and signal channels. LEMO-compatible connectors often allow for mixed configurations, accommodating both fluidic and electrical connections.
    • Sealing: The connectors should have IP-rated sealing (e.g., IP67) to protect against fluid ingress, which is critical in dental environments where exposure to liquids is common.
  3. Shielding:

    • EMC Shielding: Integrate shielding to protect signal integrity from electromagnetic interference (EMI), ensuring reliable operation of the connected devices.

Design Considerations

  1. Biocompatibility and Sterilization:

    • Materials: Ensure all materials used, including the cables, connectors, and any adhesives or overmolding, are biocompatible and suitable for repeated sterilization.
    • Sterilization Compatibility: The assembly should be capable of withstanding common sterilization methods used in dentistry, such as autoclaving, without degradation.
  2. Mechanical Durability:

    • Strain Relief: Incorporate strain relief features at the connection points to prevent wear and tear from repeated bending or pulling, especially near the connectors.
    • Flexibility: The cable assembly should be flexible enough for easy maneuvering in the dental office, without compromising on durability.
  3. Environmental Sealing:

    • Waterproofing: Ensure that both the connectors and the cable assembly are waterproof, with an IP67 rating or higher, to protect against water, saliva, and other fluids encountered in a dental environment.
    • Corrosion Resistance: Given the frequent exposure to moisture and cleaning agents, the assembly should be designed to resist corrosion over its expected lifetime.

Manufacturing Process

  1. Prototyping:

    • Develop prototypes to test the performance of the air and signal transmission, mechanical durability, and compatibility with LEMO connectors. This phase allows for refinement before full-scale production.
  2. Assembly:

    • Cable Preparation: Cut and prepare the air tubing and signal wires, ensuring precise lengths and clean terminations.
    • Connector Integration: Attach the LEMO-compatible push-pull connectors, ensuring secure and reliable connections. This may involve soldering or crimping the signal wires and securely fastening the air tubing.
    • Overmolding (Optional): Apply overmolding around the connectors if needed for additional strain relief and environmental sealing.
  3. Testing:

    • Electrical Testing: Ensure the signal channels maintain proper electrical continuity and insulation resistance.
    • Pressure Testing: Test the air channels for pressure integrity, ensuring they do not leak under operating conditions.
    • Mechanical Testing: Evaluate the assembly’s durability under simulated use, including repeated mating and demating cycles.
  4. Quality Control:

    • Implement quality control measures to verify that each assembly meets medical standards and performs reliably under the conditions expected in a dental environment.

Applications

  • Dental Handpieces: Connects dental tools that require both air for operation and electrical signals for control or monitoring.
  • Oral Irrigators: Transmits both fluid and electrical signals in devices designed for cleaning or other dental procedures.
  • Dental Imaging Equipment: Connects imaging devices that may require both air for cooling or operation and signal transmission for data handling.

Conclusion

A cable assembly designed for dentistry that includes air and signal connections with LEMO-compatible metal push-pull connectors must be durable, flexible, and compliant with medical standards. By carefully selecting materials, ensuring robust mechanical design, and conducting thorough testing, you can create a reliable product that meets the demanding requirements of dental professionals.


4o