Conventonal Smoke Alarm For Fire Security Fire Safety Alarm System





Introduction

Conventional smoke detectors are the most common type of smoke alarm used in residential and commercial buildings. They detect the presence of smoke particles in the air, which indicate a potential fire. These detectors use either an ionization or photoelectric sensor to sense smoke
When smoke enters the detector, Photoelectric detectors use a light source and a sensor. Smoke entering the detector scatters the light onto the sensor, setting off the alarm.


Parameters

Product NameSmoke DetectorRated operational voltage9 to 28VDC Volts Non-polarized
Adjustable Sensitivity1.06±.26%FTStatic current≤60µA @ 24 VDC
Alarm current30mA @ 24 VDCWork temperature-10°C~+50°C
CertificationCEHumidity≤95%.
Size103*103*55mmWeight105 g

Installation



INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.

Remove power from initiating-device circuits before installing detectors.
1. Wire the sensor base per the wiring diagram, Figure 1.
2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
3. After all sensors have been installed, apply power to the control unit.
4. Test the sensor(s) as described in the TESTING section of this manual.
5. Notify the proper authorities that the system is in operation.

Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.




Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector




Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.