Easy Installation 2 Wire Photoelectric Heat Detector For Conventional Fire Alarm System

Brand Name:XHA
Certification:CE
Model Number:XHA8025
Minimum Order Quantity:1
Delivery Time:3 Working days
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 406,Jude Building,Zhengfeng South Road,Fuyong Street,Bao'An District, Shenzhen City, Guangdong Province. China,518103
Supplier`s last login times: within 43 hours
Product Details Company Profile
Product Details

2 Wire Photoelectric Fixed Rate-Of-Rise Heat Detector For Fire Safety Alarm System





Introduction

The device is photoelectronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel.compatible with all brand conventional fire alarm system.


Parameters

Product NameHeat DetectorRated operational voltage9 to 28VDC Volts
Wired2 Wired, Non-polarizedStatic current≤80µA @ 24 VDC
Alarm current20mA @ 24 VDCWork temperature-10°C~+50°C
CertificationCEHumidity≤95%.
Size103*103*55mmWeight105 g

Feature


Conventional Smoke Detector, Operates by Advanced MCU Expert Algorithm Software.

SMD circuit board design-satisfactory quality and reliability guaranteed

They work perfectly with all conventional intelligent fire control panels
Key Specifications/Special Features
Advanced MCU Expert Algorithm Software.
Durable sensor head, no need for replacement

Easy installation and maintenance


Installation



INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.

Remove power from initiating-device circuits before installing detectors.
1. Wire the sensor base per the wiring diagram, Figure 1.
2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
3. After all sensors have been installed, apply power to the control unit.
4. Test the sensor(s) as described in the TESTING section of this manual.
5. Notify the proper authorities that the system is in operation.

Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.




Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector




Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.





China Easy Installation 2 Wire Photoelectric Heat Detector For Conventional Fire Alarm System supplier

Easy Installation 2 Wire Photoelectric Heat Detector For Conventional Fire Alarm System

Inquiry Cart 0