

Add to Cart
Conventional MCP Call Point Pull Station For Fire Fighting Fire Detection System
Introduction
A conventional pull station, also known as a manual pull station or manual call point, is an essential component of a fire alarm system that allows building occupants to manually trigger the fire alarm in the event of an emergency. Here's a more detailed explanation of the function of a conventional pull station:
Alarm Activation:
The primary function of a conventional pull station is to enable
manual activation of the fire alarm system.
When a person encounters a fire or other emergency situation, they
can pull the lever or press the button on the pull station to
initiate the alarm.
This action sends a signal to the fire alarm control panel,
indicating that a manual alarm has been triggered.
Alarm Sequence Initiation:
Upon receiving the signal from the activated pull station, the fire
alarm control panel then sets off the building's audible and visual
alarms, such as sirens, bells, and strobe lights.
This alarm sequence is intended to alert all building occupants of
the emergency, prompting them to evacuate the premises.
Notification and Emergency Response:
The activation of the pull station also typically triggers the
notification of the local fire department or other emergency
services, allowing them to respond to the reported emergency.
Depending on the fire alarm system's configuration, the pull
station activation may also trigger other safety measures, such as
the deactivation of elevators, the closure of fire doors, or the
activation of a building's emergency lighting and ventilation
systems.
Reset and Restoration:
After the emergency situation has been addressed, the pull station
must be manually reset by a trained professional, such as a fire
alarm technician or a firefighter.
Resetting the pull station involves restoring the lever or button
to its original position, which then allows the fire alarm system
to be reset and returned to its normal operational state.
Conventional pull stations are an essential safety feature in fire
alarm systems, as they provide building occupants with a clear and
accessible means to manually trigger the alarm in the event of an
emergency. Their strategic placement throughout a building, often
near exits and along common paths, ensures that they are readily
available when needed.
Parameters
Product Name | Restorable Call Point | Rated operational voltage | 9 to 33VDC Volts Non-polarized |
Relay contact rating | 1A/30VDC | Work temperature | -10°C~+50°C |
Certification | CE | Humidity | ≤95%. |
Size | 86*89*37mm | Weight | 125 g |
TO RESET
The call point can be reset by a key from alarm return to normal status
Product range
Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector
Service
1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.
5. Welcome sample order.