CYYZ61EY Hygienic Pressure Transmitter Accuracy 0.25%FS 0.5%FS Medical Technology

Brand Name:Star merter
Model Number:CYYZ61EY
Minimum Order Quantity:1PC
Payment Terms:T/T
Place of Origin:China
Price:Negotiation
Contact Now

Add to Cart

Verified Supplier
Location: Langfang Hebei China
Address: Address: Building 20, Tianshan International, Yanjiao Economic Development Zone, Sanhe City, Langfang City, Hebei Province
Supplier`s last login times: within 2 hours
Product Details Company Profile
Product Details

CYYZ61EY Hygienic Pressure Transmitter Pressure Range -0.1~0~4MPa Accuracy 0.25%FS 0.5%FS Medical Technology


The CYYZ61EY hygienic pressure transmitter is suitable for applications with hygienic requirements, and the wetted part and diaphragm are made of 316L material. Laser welding process is adopted, and there is no sanitary dead end. Suitable for the pharmaceutical and food industries. Optional intrinsically safe explosion-proof.


Basic parameters
Measuring mediumLiquids, gases (compatible with contact materials)
Pressure range-0.1~0~4MPa (see range selection table for details)
Pressure modeGauge pressure, negative pressure, absolute pressure
Medium temperature-40~85℃
Turn-on time20ms
Stable performance±0.1% FS/year
Temperature compensation-10~70℃
Temperature drift±0.01%FS/°C (within temperature compensation) ±0.05%FS/°C (outside temperature compensation)
Explosion-proof typeIntrinsically safe Ex ia II.C T6 Ga (4~20mA output only)
Ingress protectionIP65 (no display) IP54 (display) Note: The above protection level refers to the completion of the electrical connection
Durable performance1X10⁶ cycles (number of cycles from lower range to upper range)
Overall weightNo display≈ 190g with display≈270g
resolutionAnalog output 0.01%FS, digital output 0.05%FS
Output power
Output signal4~20mA,RS485,0~10VDC,0~5VDC,1~5VDC,0.5~2.5VDC
Power supply range9~28VDC,15~28VDC,3~5VDC,15~24VDC
Accuracy class
Measuring range≥ 100kPa0.25%
10kPa≤ range < 100kPa0.5%FS
Header accuracy0.5%FS digital tube (LED) display
Frequency of response
RS485 output5Hz
Absolute pressure and negative pressure30Hz
The range ≤ 10 kPa30Hz
other100Hz
Power range
Voltage type≤0.02Us(W),≤0.008Us(W),≤0.001Us(W)
Current type≤0.02Us(W)
Digital≤0.02Us(W),≤0.015Us(W)
Load characteristics
Voltage type≥10kΩ
Current typeNo display load ≤{(Us-7.5)÷0.02}Ω
With display load ≤{(Us-12)÷0.02}Ω (Us=supply voltage)
Environmental conditions
Ambient temperature-40~85℃
Ambient humidity0%~95%RH (no condensation, no condensation)
Overload capacity
Overload pressure300%FS,200%FS,12kPa,50kPa,300kPa,480kPa,750kPa,800kPa,1.2MPa,2MPa
Burst pressure600%FS,500%FS,400%FS,20kPa,200kPa,600kPa,900kPa,1.25MPa,2MPa,3MPa,5MPa,2MPa,3MPa,5MPa
Overall material
diaphragm316L stainless steel (in contact with the medium to be measured)
Process connections316 stainless steel (in contact with the medium to be measured)
enclosure304 stainless steel
O-ringsNitrile rubber (contact with the medium to be measured)
Displays the shellABS Engineering Plastics (LED Display)
Hersmann connectorsABS engineering plastics
Mechanical stability
Vibration resistance10g(20… 2000Hz) in accordance with the IEC60068-2-6 standard
Impact Resistance:500g/ms meets IEC60068-2-27 standard
Electrical protection
Short-circuit protectionperpetual
Reverse polarity protectionNo damage, but no work
Insulation resistance≥100MΩ 500VDC
Dielectric Strength:500VAC
Output limits
The output is minimal4mA,0,0.001VDC,0.05VDC
The output is maximum20mA,2000,10VDC,5VDC
Manual
Product Information -Chinese (CN)PDF
Product Information -English (EN)PDF
Product selection -Chinese (CN)PDF
Product selection -English (EN)PDF
Installation instructions -Chinese (CN)PDF
Installation instructions -English (EN)PDF
Protocol -Chinese (CN)PDF
Protocol -English (EN)PDF

China CYYZ61EY Hygienic Pressure Transmitter Accuracy 0.25%FS 0.5%FS Medical Technology supplier

CYYZ61EY Hygienic Pressure Transmitter Accuracy 0.25%FS 0.5%FS Medical Technology

Inquiry Cart 0