CYYZ31AY Waterproof Pressure Transmitter Measuring Range -100kPa~0~60MPa General Industry Accuracy 0.1%FS 0.25%FS 0.5%FS
The CYYZ31AY pressure transmitter is not only compact, but also of excellent quality, with a degree of protection up to IP68, suitable for pressure measurement sites in wet or long-term immersion.
Base parameters | |
Measuring medium | Liquid or gas (compatible with contact material) Range < 10kPa (non-conductor, non-corrosive, non-explosive gas with humidity ≤90%RH, no condensation). |
Measuring range | -100kPa~0~60MPa (see range selection table for details) |
Type of pressure | Gauge pressure, absolute pressure, negative pressure |
Temperature compensation | Standard (temperature compensation -10-70°C) 0.25%FS, 0.5%FS Optional (temperature compensation -40-80°C) 0.1%FS, 0.25%FS (Note) Note: The range range is ≤ 10kPa, and the temperature compensation range is -10~70°C |
Accuracy class | 0.1%FS,0.25%FS,0.5%FS |
Response frequency | 5Hz,30Hz,100Hz |
Stable performance | ± 0.1% FS/year |
Temperature drift | ±0.01%FS/°C (temperature compensation range) ±0.05%FS/°C (outside temperature compensation range) |
Overall weight | ≈540g (including 4m cable) |
resolution | Analog output 0.01%FS, digital output 0.05%FS |
Degree of protection | IP68 |
Output power | |
Output signal | 4~20mA,RS485,0~10VDC,0~5VDC,1~5VDC,0.5~2.5VDC |
Power supply range | 9~36VDC,15~36VDC,3~5VDC |
Power range | |
Current type | ≤0.02Us(W) |
Digital | ≤0.015Us(W) |
Voltage type | ≤0.008Us(W)≤0.001Us(W) |
Load characteristics | |
Voltage type | ≥10kΩ |
Current type | ≤{(Us-7.5)÷0.02(Us=Supply voltage)}Ω |
Environmental conditions | |
Media temperature | -40~85℃ |
Ambient temperature | -40~85℃ |
Ambient humidity | 0%~95%RH(no condensation, no condensation) |
Overload capacity | |
Overload pressure | 300%FS,200%FS,150%FS,12kPa,50kPa,300kPa,480kPa,750kPa,800kPa,1.2MPa,2MPa,3MPa,5MPa |
Burst pressure | 600%FS,500%FS,400%FS,300%FS,20kPa,200kPa,600kPa,900kPa,1.25MPa,2MPa,3MPa,5MPa,9MPa,12.5MPa |
Overall material | |
diaphragm | 316L stainless steel (contact with the medium to be measured) |
Process connection | 304 stainless steel (contact with the medium to be measured) |
enclosure | 304 stainless steel |
Seals | Nitrile rubber (contact) fluoroelastomer (seen pressure and blasting chart (contact with the medium to be measured) |
Cable | Range≤ 1.6MPa φ7.2mm polyurethane air-shielded cable (UV protection) Range> 1.6MPa or absolute pressure (A) φ5mm polyurethane shielded cable (UV protection) |
Mechanical stability | |
Seismic performance | 10g(20… 2000Hz) conforms to IEC60068-2-6 standard |
Impact resistance: | 500g/ms conforms to IEC60068-2-27 standard |
Electrical protection | |
Short-circuit protection | perpetual |
Anti-polarity protection | No damage, but not working |
Insulation resistance | ≥100MΩ500VDC |
Dielectric strength: | 500VAC |
Output limits | |
The output is minimal | 4mA, 0, 0.001VDC, 0.05VDC (Others: 3.8mA) |
Output maximum | 20mA, 2000, 10VDC, 5VDC (others: 26mA, 2000, 12VDC, 5VDC) |