Add to Cart
CYW26Y Deep Well Input Liquid Level Transmitter Measuring Range 0~200~2000mH2O Underground Water Level Monitoring
The outer diameter of the CYW26Y deep well input liquid level transmitter is only 19mm, and it can measure both liquid level and temperature simultaneously. The anti condensation process design extends its service life. In addition, the internal circuit enhances anti-interference processing, effectively reducing the interference of the water pump, making it an ideal product for deep well water level measurement.
Basic parameters | |
Measuring medium | Water (H2O) or liquids compatible with contact materials |
Measuring range | 0~200~2000mH2O (see range selection table for details) |
Level accuracy | 0.25%FS,0.5%FS |
Temperature accuracy | ±0.5℃ |
Temperature range: | 0~100℃ |
Medium temperature: | 0~100℃ |
Pressure mode: | Sealing Pressure(S) |
Response Frequency: | The analog signal output ≤ 50Hz, and the digital signal output ≤ 5Hz |
Stable performance: | ±0.1% FS/year |
Accuracy class: | 0.25%FS,0.5%FS |
Temperature Compensation: | -10~70℃ |
Overload Capacity: | 200% full scale |
Temperature Drift: | ±0.01%FS/°C (within temperature compensation) ±0.05%FS/°C (outside temperature compensation) |
Ingress protection | IP68 |
Overall weight | Probes ≈ 290g cable ≈ 110g per meter |
Turn-on time | 20ms |
resolution | Analog output 0.01%FS, digital output 0.05%FS |
Output power | |
4~20mA | 9~28VDC |
RS485 | 5~28VDC |
Maximum power | |
4~20mA | ≤0.02Us(W) |
RS485 | ≤0.015Us(W) |
Load characteristics | |
Current type | Load ≤{(Us-7.5)÷0.02}Ω (Us=Supply Voltage) |
Environmental conditions | |
Ambient temperature | -40~100℃ |
Overall material | |
Diaphragm | 316L stainless steel (in contact with the medium to be measured) |
Outer shell | 304/316L stainless steel (in contact with the medium to be measured) |
Seals | Fluoroglue (in contact with the medium to be measured) |
Seals | Fluoroglue (in contact with the medium to be measured) |
Cable | XL05 polyethylene φ7.8 (temperature resistance 120°C) steel wire layer cable (contact with the measured medium) |
Mechanical stability | |
Seismic performance | 10g(20… 2000Hz) in accordance with IEC60068-2-6 standard |
Impact resistance | 500g/ms meets IEC60068-2-27 standard |
Electrical protection | |
Short-circuit protection | eternity |
Anti-polarity protection | No damage, but no work |
Insulation resistance | ≥100MΩ,500VDC |
Dielectric strength | 500VAC |
Output limits | |
Level output | |
4-20mA | 4~20mA |
RS485 | 0~2000 |
Liquid temperature output | |
4-20mA | 2.5~26mA |
RS485 | 0~1500 |