CWS28Y Outdoor Type Temperature And Humidity And Atmospheric Pressure Integrated Transmitter Various Outdoor Environments
CWS28Y outdoor type temperature and humidity and atmospheric pressure integrated transmitter is a comprehensive transmitter integrating temperature and humidity and atmospheric pressure sensor, its quality is excellent, suitable for a variety of outdoor temperature and humidity and atmospheric pressure monitoring, with wide power supply range, strong weather resistance and other advantages.
Base parameters | ||||||
Measuring medium | Gas (compatible with contact material) | |||||
Temperature range | -40℃~85℃ | |||||
Humidity range | 0-100%RH | |||||
Pressure range | 0~110kPa(range of use: 1~110kPa) | |||||
Response frequency | ≤2Hz | |||||
On-time | 400ms | |||||
Overall weight | ≈650g | |||||
Degree of protection | IP65 | |||||
Output signal | RS485 | |||||
Power supply range | 9~36VDC | |||||
Maximum power | ≤0.015Us(W) Note: Us=Supply voltage | |||||
Temperature and humidity parameters | ||||||
Stable performance | Temperature ±1%RH FS/year, Humidity ±0.2°C/year | |||||
Speed of response | Temperature response time 55s, humidity response time 35s (temperature at 10°C per step, humidity at 10%RH per step, gas flow rate is 0.1m/s) | |||||
Atmospheric pressure parameters | ||||||
Type of pressure | Absolute pressure | |||||
Accuracy class | 0.25%FS | |||||
Response frequency | 2Hz | |||||
Stable performance | ± 0.1% FS/year | |||||
Temperature compensation | -10~70℃ | |||||
Temperature drift | ±0.01%FS/°C (temperature compensation range), ±0.05%FS/°C (outside temperature compensation range) | |||||
Environmental conditions | ||||||
Ambient temperature: | -40~85℃ | |||||
Ambient humidity: | 0%~95%RH( Non-condensing, non-condensing) | |||||
Electrical protection | ||||||
Short-circuit protection | perpetual | |||||
Anti-polarity protection | No damage, but not working | |||||
Insulation resistance | ≥100MΩ,500VDC | |||||
Dielectric strength | 500VAC | |||||
Output limits | ||||||
RS485 | Output minimum 0, output maximum temperature 1650, humidity 1000, atmospheric pressure 15000 | |||||
Overall material | ||||||
Body shell | ABA (Contact with the medium to be measured) | |||||
Over the filter | Polyethylene (density 50μm) (contact with the measured medium) | |||||
Cable locking head | Nylon (lock wire diameter 4~6mm) (contact with the measured medium) | |||||
Confidential Documents | Nitrile rubber (contact with the medium to be measured) | |||||
Mechanical stability | ||||||
Seismic performance | 5g(20… 2000Hz) in accordance with IEC60068-2-6 standard | |||||
Impact resistance | 500g/1ms conforms to IEC60068-2-27 standard |