CMF5032 Communication Mode RS 485 (MODBUS) Calibration Method Air at 20℃, 101.325 kPa

Brand Name:Consensic
Model Number:CMF5032
Minimum Order Quantity:Please contact us for details
Delivery Time:3-7 work days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram/Alipay/business-to-business
Place of Origin:WUXI
Contact Now

Add to Cart

Verified Supplier
Location: Wuxi China
Address: No.86,Dicui Road,B5Building, Fourth Floor,Room 401
Supplier`s last login times: within 15 hours
Product Details Company Profile
Product Details

Performance Parameters

Functional Items: CMF 5032

Performance ParameterSpecificationUnitRemarks
Power Supply Voltage8~24 VDC, 50 mAVDCSelectable
Accuracy±1.5%FS
Response Time65msSelectable
Maximum Pressure0.8MPaCustomizable
Communication ModeRS 485 (MODBUS)
Output MethodAnalog outputs of 1-5VDC
4-20 mAOptional
TemperatureMedium: -10~65, Ambient: -25~85
JogglePT1/4Customizable
Calibration MethodAir at 20℃, 101.325 kPa
Overall MaterialStainless Steel

Use Instructions

  1. Pre-Use Reading:Please read the instructions carefully before using the product.
  2. Environment Suitability:Best used in a clean gas environment.Not suitable for environments with large amounts of dust, oil pollution, and multiphase flow.For use in environments with large quantities of water vapor, please contact the manufacturer in advance.
  3. Industry Application:Suitable for gas measurement, monitoring, and control in automotive, industrial, commercial, and equipment industries.Not suitable for environments other than those specified.
  4. Operational Compliance:Follow relevant operating specifications and safety precautions strictly during use or application.
  5. Liability Disclaimer:Wuxi Consensic Electronic Technology Co., Ltd. and its subsidiaries will not be liable for damage resulting from improper use of the product.Other matters shall be subject to the sales contract.

Matters Needing Attention

  1. Operational Environment:Ensure the product operates in the environment defined in the manual.
  2. Installation and Connection:Pay attention to the gas flow mark during installation.Perform connection and leakage detection according to the corresponding regulations.
  3. Product Use:Avoid online installation of pipes, cleaning of pipes, or other operations that may introduce a large amount of impurities as they may damage the product.
  4. Medium Conditions:Presence of water in the medium or immersion in water may cause sensor sensitivity decline or damage.
  5. Power Supply Caution:Incorrect connection of the positive and negative electrodes of the power supply can burn out the sensor's internal circuit, affecting its use.