Add to Cart
High-Precision Output: The CPS610 features a 24-bit digital I2C interface that provides precise pressure readings. With a high-resolution output, it ensures accurate measurement even in environments requiring fine tolerance, such as medical devices and industrial monitoring systems.
Customizable Pressure Ranges: The CPS610 can be customized to measure differential pressure and gauge pressure at various predefined ranges (0.2 KPa, 0.5 KPa, 2.5 KPa, and 10 KPa). This flexibility allows the sensor to adapt to specific application needs, whether in low-pressure medical equipment or higher-pressure industrial control systems.
Multi-Order Temperature Compensation: The sensor integrates an advanced algorithm for multi-order temperature compensation, ensuring accurate measurements even in fluctuating environmental conditions. This feature is crucial for maintaining stability and performance over a wide range of temperatures, especially in critical applications like respiratory monitoring and firefighting systems.
RoHS Compliant: The CPS610 is fully compliant with RoHS standards, making it environmentally friendly by eliminating harmful substances. This is an essential factor in industries like healthcare and consumer electronics, where regulatory compliance is mandatory.
Durability and Easy Installation: Packaged in a robust SOIC-16 form with vertical dual air nozzles and barbs, the CPS610 is designed for quick and reliable integration into various systems. Its durable packaging ensures protection against external damage while simplifying installation, making it suitable for long-term, maintenance-free operation.
Low Power Consumption: The sensor operates efficiently with low power consumption, which is particularly beneficial in battery-operated medical devices and energy-sensitive industrial applications.
These performance parameters combine to make the CPS610 a versatile and reliable choice for high-precision pressure monitoring across a variety of sectors.
Parameter | Minimum | Typical | Maximum | Unit | Remarks |
---|---|---|---|---|---|
Service Voltage | 1.8 | 5 | 5.5 | V | |
Supply Current | - | 1.7 | - | mA | At 25°C |
Pressure Range | 0.2, 0.5, 2.5, 10 | - | - | kPa | Customizable for differential and gauge pressure |
Pressure Medium | - | Dry, non-corrosive gas | - | - | |
Overload Pressure | - | - | 2x | - | |
Storage Temperature | -40 | - | +125 | °C | |
Working Temperature | -20 | - | +85 | °C | |
Output Voltage | 10% | - | 90% | V_SUPPLY | Of service voltage |
Response Time | - | 3 | - | ms | |
Stabilization Time | - | 10 | - | ms | |
Accuracy | - | ±1.5 | - | %Span | |
Long-Term Stability | - | ±0.2 | - | %FS |