F-K series is a high-speed optical laser micrometer based on laser diffraction principle. It is fast enough to provide diameter, lumps and necks measurement in 2-axis.

Sampling frequency can reach to 10KHz due to no motor running speed limitation,which enables to get more information of the object under measurement.

Measurement is accurate even on vibrating objects.




Extremely short exposure time of 0.5us

Featuring an incredibly short exposure time, F2010-k is good at capturing object images without any blur or shadow, ensuring precise measurement accuracy.



Applications



Touch Screen,Computer,Cellphone

DALA F2010-K can be managed by computer ,cellphone and Touch screen,like parameter setting ,measurement data management ,

and so on,customers can choose as their application request.

Technical Specification


ModelF2010-K
Axis2-axis
Measurement datadiameter and ovality, lump and necks
Frequency10KHz/axis
Measurement range0.2~10mm
Repeatability(1)±0.1μm
Accuracy(2)±(0.0005+0.01%*D)mm
Min defect height0.01mm
Min defect length(3)0.2mm(wire speed120m/min)
0.8mm(wire speed500m/min)
Size155*140*58mm
Working power source24V ±10% 40VA
Running temperature5℃~50℃
DisplayLED display
Commuincation port

Standard:WIFI,RS485 MODBUS RTU,CAN

Option:PROFIBUS,PROFINET, EtherNet/IP,EtherCAT

Data colletion & analysisavailable (option DS14 ZT display and control system,DMS1000)
Out-of-tolerance alarmavailable
Transparent modeavailable

Note:

(1) set sliding window as 100ms, outside diameter repeatability of φ1mm round rod at measurement center area

(2) set sliding window as 100ms, outside diameter deviation of φ1mm round rod at measurement area

(3)set defect measurement average time as 0ms, the minimum defect length which cannot be missed at the measurable area

(4)PI feedback control is option, but must order at placing order