Measurement Principle

When the object is caught by laser beam passed through lens, a bright and dark area will be formed on CCD,then the object dimension will be accurately calculated through software analysis and calculation.



Strong Adaptability to Mist and Dust


Precision CNC manufacturing, with impact resistance of 10G/6ms, vibration resistance of 10-55Hz/1.5 in XYZ for 2 hours, preventing the
optical parts from damaging.
Individual temperature compensation technology enables the device measurement results not to be affected by temperature change.*
*The measurement diameter change will be≤0.001mm if object diameter is 10mm.

Measurement is accurate even if there is water and dust

Thanks to individual optical system and measurement algorithm, the measurement data of TL-2025D is still accurate at complex environment.


Application



Touch Screen,Computer,Cellphone

DALA TL-2025D can be managed by touch screen,computer and cellphone,like parameter setting ,measurement data management ,and so on,customers can choose as their application request.

Technical Specification


ModelTL-2025D
Axis2-axis
Measurement dataDiameter &Ovality,Width&Thcikness, Lump&Necks
Application fieldRound wire ,Transparent wire, Flat wire
Sampling frequency10KHz(signal axis)
Measurement range0.2~25mm
Repeatability(1)±0.1μm
Measurement accuracy(2)±2μm
Dimensional296*270*54mm
Working power24V ±10% 40VA
DisplayLED
Communication portDefault:WIFI,RS485 MODBUS RTU,CAN
Option:PROFIBUS,PROFINET, EtherNet/IP Industrail bus and Industrial EtherNet,etc.
Electrical portDefault:Digital output (relay), Digital input,Analog input encoder pulse input port.
Option: PI feedback control(3)
Environmental adaptability

Working Environment

0~50 ℃
Working Environment20~85%RH(No condensation)
Working environmental brightnessBrightness of working environment Incandescent light, fluorescent lamp 3000lx or less
Vibrating resistance10~55Hz full amplitude 1.5mm in XYZ direction for 2 hours
Impact resistance10G/6ms
Data colletion & analysisDMS1000 measurement software system,DS14 ZT display and control system
Out-of-tolerance alarmSupport
Transparent modeSupport
Water-proof gradeIP65

Note:

(1)Set the average number of times to 1150 and measure the ±2σ value of the round standard rod of diameter 10mm at the measurement area center;

(2)For object diameter of 10mm, the measurement accuracy is ±2um when it moves in the center of 8*8mm;

(3)PI feedback control option shall be ordered at placing device order.