Product Details
Dual Channel LD-202 Loop Sensor Detector 12-24VADC Direction
Recognition for One-way Road
Product Name: JUTAI LD-202 Dual Channel Loop Detector 12-24VADC 15~2000μH for
Barrier Gate Opening and Safety
Advantages:
Extensive Sensing Range and High Sensitivity: The LD-202 sensor
offers a broad sensing range from 15 to 2000μH coupled with
exceptional sensitivity, ensuring precise detection of various
vehicles for reliable performance.
Automatic Reset Function: With its automatic reset function, the
LD-202 sensor autonomously resets in case of malfunction, enhancing
system stability and reliability without the need for manual
intervention.
Direction Recognition Capability: Featuring advanced direction
recognition, the LD-202 sensor accurately identifies specific
vehicle movement directions to trigger relay output, ensuring
precise control over gate operations.
40000V Lightning Protection: Equipped with robust 40000V lightning
protection, the LD-202 sensor is effectively shielded against
damage from lightning strikes, ensuring prolonged durability and
reliability.
Wide Operating Environment Range: Designed for versatile
applications, the LD-202 sensor operates within a wide temperature
range from -40°C to +70°C, ensuring consistent performance even in
challenging weather conditions.
Functionality:
Vehicle Detection: Utilizing inductive sensing technology, the
LD-202 sensor accurately detects vehicles without physical contact,
relying on changes in inductance within the loops caused by the
vehicle's metal mass.
Direction Recognition: Advanced direction recognition capabilities
enable the LD-202 sensor to identify specific vehicle movement
directions, facilitating precise control over gate operations.
Automatic Reset: The LD-202 sensor incorporates an automatic reset
function, ensuring seamless operation and system reliability by
automatically resetting in case of malfunction.
Relay Output: Providing relay output signals upon vehicle
detection, the LD-202 sensor enables various actions such as gate
opening, traffic light control, and vehicle counting.
Applications:
Traffic Management Systems: Deployed in traffic control systems to
detect vehicles at intersections, toll booths, and parking
entrances/exits, facilitating efficient traffic flow management.
Gate Automation: Integrated into gate control systems for automatic
opening and closing of gates in residential, commercial, and
industrial environments, enhancing security and convenience.
Parking Facilities: Utilized in parking lots and garages to manage
vehicle entry and exit, monitor parking occupancy, and enforce
parking regulations, optimizing parking space utilization.
Access Control: Employed in access control systems to authorize
vehicle entry at secured locations such as gated communities,
industrial facilities, and military installations, ensuring
controlled access and security.
Traffic Light Control: Used to trigger traffic light changes based
on vehicle presence and direction, optimizing traffic flow and
minimizing congestion at intersections and roadways.
Vehicle Counting: Applied in vehicle counting applications for
traffic studies, parking occupancy monitoring, and retail traffic
analysis, providing valuable insights for traffic management and
business operations.
Connections
Indicates And Switch
Power Led: RED power LED indicates "Power ON"
CH1 Detecting Led: Continuously On: Indicates vehicle detection.
Blinking slowly: Indicates loop is short circuit or the number of
twists after the loop is not enough.
Blinking fast: Indicates loop is open circuit or too many twists
after the loop.
CH2 Detecting Led: Continuously On: Indicates vehicle detection.
Blinking slowly: Indicates loop is short circuit or the number of
twists after the loop is not enough.
Blinking fast: Indicates loop is open circuit or too many twists
after the loop.
Sensitivity Selection
Sensitivity and frequency of the loop can be adjusted by 7-way dip
switch and 10-way dip switch setting.
User can select 8 different setting by changing the setting of the
dipswitch to different modes as in the dipswitch setting tables
below. Dip switch 6, 7 and 8 for CH1 sensitivity selection with 0.8
being the least sensitive and 0.015 being the most sensitive.
Dip switch 3, 4 and 5 for CH2 sensitivity selection with 0.8 being
the least sensitive and 0.015 being the most sensitive.
3. Switch 1=S1 : Channel 1 Loop Function Selection (10 way dip
switch)
(1)(Switch 1) DIP 1 & DIP 2 Special Sensitivity Increase For
Both Trailer (Both Channels).
(2)(Switch 1=S1) D3, D4, D5 and (Switch 2=S2) D1, D2 Setting
Special Functions (Mode1, 2, 3 Direction Detection. Mode 4, 5, 6
Normal mode, two loop detection are separated)
(3)(Switch 1=S1) D6 & D7 & D8 and (Switch 2=S2) D3 & D4
& D5 Setting CH1 and CH2 Sensitivity Selection (Eight Levels
Choices).
(4)(Switch 1=S1) D9 & D10 and (Switch2=S2) D6, D7 Setting
Frequency (20 K to 100 KHz).
Reset Button: It's important to note that the LD-200 requires
resetting each time a setting change is made to the Dip switches.
Loop Installation:
The loops should be sealed using a "quick-set" black epoxy compound
or hot bitumen mastic to seamlessly blend with the roadway surface.
When installation, please keep the product plug and socket in the
vertical direction
Application:
The JUTAI LD-200/202 Double Channel Vehicle Loop Detector series,
equipped with direction recognition functionality, is ideal for
numerous single-channel entry and exit scenarios. When integrated
with the JUTAI One Door Controller (Model: AC-11), JUTAI Gate
Barrier (Model: BR-110), and JUTAI Long-Range RFID Reader (Model:
PUHF-9), combined with high-temperature-resistant loop coils
(Model: JTHT-11), it forms an efficient solution for single-channel
entry/exit access control systems.
The operational principle is as follows:
Entry Process:
- Upon a vehicle's entry into the community or parking lot,
simultaneous activation of the two loop coils occurs.
- The JUTAI Double Channel Loop Detector (LD-202) triggers the UHF
reader positioned at the entrance.
- Upon reading the card ID, the UHF reader transmits the ID to the
controller (AC-11) via Wiegand output.
- The controller verifies the ID's validity and outputs a relay
signal to open the gate barrier.
- Once the vehicle enters the community or parking lot, the barrier
arm automatically lowers.
- The safety and anti-smashing function is facilitated by the JUTAI
Single Channel Loop Detector (LD-100/102).
Exit Process:
- As the vehicle exits the community or parking lot and passes the
internal UHF reader, the LD-202 triggers the UHF reader.
- The reader reads the card and sends the ID to the controller.
- Upon validation of the ID, the controller emits a relay signal to
open the gate barrier.
- After the vehicle exits the community or parking lot, the barrier
arm lowers automatically.
- The safety and anti-smashing function is facilitated by the JUTAI
Single Channel Loop Detector (LD-100/102).
In both scenarios, the LD-202's Direction Recognition Function
ensures accurate and efficient operation.
JUTAI LD-202 Double Channel Loop Detector can function as two
independent single-channel loop detectors, offering versatility and
cost-efficiency. This configuration is ideal for standard one-in
and one-out parking lots, where a single barrier and long-range
reader are installed at both the entrance and exit. One loop coil
is dedicated to triggering the reader and reading the card, while
the other loop coil is utilized for the barrier's anti-smashing
function. Enabling the Independent Working Mode function of the
LD-202 streamlines operations and reduces hardware costs, making it
a practical choice for various applications.
The operational principle is as follows:
Entry Process:
- Upon a vehicle's entry into the community or parking lot,
simultaneous activation of the two loop coils occurs.
- The JUTAI Double Channel Loop Detector (LD-202) triggers the UHF
reader positioned at the entrance.
- Upon reading the card ID, the UHF reader transmits the ID to the
controller (AC-11) via Wiegand output.
- The controller verifies the ID's validity and outputs a relay
signal to open the gate barrier.
- Once the vehicle enters the community or parking lot, the barrier
arm automatically lowers.
- The safety and anti-smashing function is facilitated by the JUTAI
Single Channel Loop Detector (LD-100/102).
Exit Process:
- As the vehicle exits the community or parking lot and passes the
internal UHF reader, the LD-202 triggers the UHF reader.
- The reader reads the card and sends the ID to the controller.
- Upon validation of the ID, the controller emits a relay signal to
open the gate barrier.
- After the vehicle exits the community or parking lot, the barrier
arm lowers automatically.
- The safety and anti-smashing function is facilitated by the JUTAI
Single Channel Loop Detector (LD-100/102).
In both scenarios, the LD-202 Direction Recognition Function
ensures accurate and efficient operation.
Company Profile
Shenzhen Jutai COMM Co., Ltd. is a high-tech privately-owned
enterprise that integrates production, research and development,
and sales. Our company is dedicated to the research and development
as well as system integration of security products, achieving an
intelligent one unified platform that integrates access control,
parking management (parking charging system and parking guidance
system), traffic lights system, and other functionalities.
Additionally, we have pioneered self-innovation, introducing
pioneering concepts in both infrared detection and radar sensing
devices. Our innovative technologies consistently lead the
industry, and for our clients, we provide premium products, novel
application concepts, comprehensive system solutions, and
comprehensive technical support. At JUTAl, we believe in the
limitless pursuit of technology. Our research and development
philosophy centers around diligence and excellence, striving for
continuous improvement. Our ultimate goal is to transcend current
standards, providing safer and more convenient services for our
living spaces. We firmly believe that our greatest success lies in
the success of our customers. Innovation, transcendence, and
excellence are our guiding principles.